Optimization of kV Selection on Third-generation High-pitch Dual-source Coronary CT Angiography Using Ultra-low Contrast Media Protocols in Patients with Body Mass Index between 20-30 kg/munder Automatic Tube Voltage Selection.
	    		
		   		
		   			
		   		
	    	
    	- VernacularTitle:第3代双源CT自动管电压选择技术在行超低对比剂用量冠状动脉CT血管成像体质量指数20~30 kg/m2患者中的应用价值
 - Author:
	        		
		        		
		        		
			        		Ming WANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yan YI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Jian CAO
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yining WANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Bing QI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Shuo MA
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yun WANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Journal Article
 - MeSH: Body Mass Index; Computed Tomography Angiography; methods; Contrast Media; Humans; Prospective Studies; Radiation Dosage; Radiographic Image Interpretation, Computer-Assisted
 - From: Acta Academiae Medicinae Sinicae 2017;39(1):49-55
 - CountryChina
 - Language:English
 - 
		        	Abstract:
			       	
			       		
				        
				        	Objective To investigate the application of automatic tube voltage selection (CARE-kV)coronary CT angiography (CCTA)using ultra-low contrast media (CM)protocols in patients with body mass index (BMI)between 20 kg/mand 30 kg/mon third-generation dual-source CT (DSCT). Methods We prospectively included 134 consecutive patients with BMI between 20 kg/mand 30 kg/mwho underwent CARE-kV prospective high-pitch CCTA on third-generation DSCT using the ultra-low CM protocols and divided them into two groups according to the CARE-kV results:70 kV group(n=91):65 patients with normal BMI(20 kg/m≤BMI≤25 kg/m)and 26 patients with high BMI(25 kg/m
 
            