A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jae Seung LEE
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Eun Hoe GOO
			        		
			        		;
		        		
		        		
		        		
			        		Cheol Soo PARK
			        		
			        		;
		        		
		        		
		        		
			        		Sun Yeob LEE
			        		
			        		;
		        		
		        		
		        		
			        		Han Joo LEE
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Physics, Soonchunhyang University Graduate School, Asan, Korea.
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Transmission gain values;
			        		
			        		
			        		
				        		Center frequency adjustment;
			        		
			        		
			        		
				        		Artifacts;
			        		
			        		
			        		
				        		Absolute contrast to noise ratio
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Artifacts;
				        		
			        		
				        		
					        		Body Weight;
				        		
			        		
				        		
					        		Compensation and Redress;
				        		
			        		
				        		
					        		Female;
				        		
			        		
				        		
					        		Head;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Magnets;
				        		
			        		
				        		
					        		Male;
				        		
			        		
				        		
					        		Neck
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Korean Journal of Medical Physics
	            		
	            		 2009;20(4):244-252
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:Korean
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, 150=3.23+/-0.35, 4.31+/-0.02 4.23+/-0.21, 5.12+/-0.25, 7.13+/-0.72, 8.31+/-0.01, 5.21+/-0.15, 6.14+/-0.08, 5.23+/-0.72, 5.91+/-0.06, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:-1.44+/-0.11, -2.7+/-0.04, 90:-2.18+/-0.42, -4.41+/-0.43, 110:-2.89+/-0.43, -5.23+/-0.02, 130:-2.34+/-0.05, -5.26+/-0.01, 150: -2.09+/-0.08, -3.87+/-0.12, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.