Bioavailability of EVA-Coated Metallic Stents Implanted in the Rabbit Iliac Artery.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.4070/kcj.2003.33.7.614
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Sang Woo NAM
			        		
			        		;
		        		
		        		
		        		
			        		Byung Hyun RHEE
			        		
			        		;
		        		
		        		
		        		
			        		Jei Keon CHAE
			        		
			        		;
		        		
		        		
		        		
			        		Eun Kyung KIM
			        		
			        		;
		        		
		        		
		        		
			        		Chang Ho SONG
			        		
			        		;
		        		
		        		
		        		
			        		Dong Hun LEE
			        		
			        		;
		        		
		        		
		        		
			        		Gil Son KHANG
			        		
			        		;
		        		
		        		
		        		
			        		Won Ho KIM
			        		
			        		;
		        		
		        		
		        		
			        		Jae Ki KO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Polyvinyls;
			        		
			        		
			        		
				        		Stents;
			        		
			        		
			        		
				        		Restenosis
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Biological Availability*;
				        		
			        		
				        		
					        		Coronary Disease;
				        		
			        		
				        		
					        		Coronary Vessels;
				        		
			        		
				        		
					        		Drug Delivery Systems;
				        		
			        		
				        		
					        		Iliac Artery*;
				        		
			        		
				        		
					        		Membranes;
				        		
			        		
				        		
					        		Polyvinyls;
				        		
			        		
				        		
					        		Rabbits;
				        		
			        		
				        		
					        		Stents*
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Korean Circulation Journal
	            		
	            		 2003;33(7):614-619
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:Korean
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	BACKGROUND AND OBJECTIVES: Coronary artery stenting actually shows a high efficacy in the treatment of coronary heart disease, but has the major limitation of restenosis. The ethylene-vinyl acetate copolymer (EVA), a biocompatible nondegradable copolymer, has been employed as a rate-controlling membrane in several drug delivery systems. Herein, the feasibility of an EVA-coated coronary stent was evaluated as a possible route for localized drug delivery. MATERIALS AND METHODS: A total of 15 rabbits were employed in this study. An uncoated stent was implanted into the non-diseased iliac artery in six rabbits, and an EVA-coated stent into a further nine. On the 30th day following the stent implantations, stented segments of the iliac arteries were removed for histological processing and morphometric analysis. RESULTS: The mean neointimal area of the uncoated and coated groups were 1.009 and 1.011 mm2 (p=0.56), respectively. No inflammatory cells were found in coated group. There were no apparent differences between the two groups. CONCLUSION: The results from this study have demonstrated that an EVA-coated coronary stent might be an appropriate method for the controlled-release of a drug.