Predictors and Clinical Impact of Inappropriate Implantable Cardioverter-Defibrillator Shocks in Korean Patients.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3346/jkms.2012.27.6.619
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jeong Hoon YANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Kyeongmin BYEON
			        		
			        		;
		        		
		        		
		        		
			        		Hye Ran YIM
			        		
			        		;
		        		
		        		
		        		
			        		Jung Wae PARK
			        		
			        		;
		        		
		        		
		        		
			        		Seung Jung PARK
			        		
			        		;
		        		
		        		
		        		
			        		June HUH
			        		
			        		;
		        		
		        		
		        		
			        		June Soo KIM
			        		
			        		;
		        		
		        		
		        		
			        		Young Keun ON
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Division of Cardiology, Department of Medicine, Cardiac and Vascular Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. yk.on@samsung.com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Implantable Cardioverter-Defibrillator;
			        		
			        		
			        		
				        		Inappropriate Shock
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Adult;
				        		
			        		
				        		
					        		Aged;
				        		
			        		
				        		
					        		Atrial Fibrillation/complications;
				        		
			        		
				        		
					        		Defibrillators, Implantable/*adverse effects;
				        		
			        		
				        		
					        		Equipment Failure;
				        		
			        		
				        		
					        		Female;
				        		
			        		
				        		
					        		Hospitalization;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Kaplan-Meier Estimate;
				        		
			        		
				        		
					        		Male;
				        		
			        		
				        		
					        		Middle Aged;
				        		
			        		
				        		
					        		*Predictive Value of Tests;
				        		
			        		
				        		
					        		Republic of Korea;
				        		
			        		
				        		
					        		Retrospective Studies;
				        		
			        		
				        		
					        		Risk Factors;
				        		
			        		
				        		
					        		Shock/*etiology/mortality;
				        		
			        		
				        		
					        		Tachycardia, Supraventricular/complications
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Journal of Korean Medical Science
	            		
	            		 2012;27(6):619-624
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Limited data are available on inappropriate shocks in Korean patients implanted with an implantable cardioverter-defibrillator (ICD). We investigated the impact of inappropriate shocks on clinical outcomes. This retrospective, single-center study included 148 patients treated between October 1999 and June 2011. The primary outcome was a composite event of all-cause mortality or hospitalization for any cardiac reason. The median follow-up duration was 29 months (interquartile range: 8 to 53). One or more inappropriate shocks occurred in 34 (23.0%) patients. A history of atrial fibrillation was the only independent predictor of inappropriate shock (hazard ratio [HR]: 4.16, 95% confidence interval [CI]: 1.89-9.15, P < 0.001). Atrial fibrillation was the most common cause of inappropriate shock (67.7%), followed by supraventricular tachycardia (23.5%), and abnormal sensing (8.8%). A composite event of all-cause mortality or hospitalizations for any cardiac reason during follow-up was not significantly different between patients with or without inappropriate shock (inappropriate shock vs no inappropriate shock: 35.3% vs 35.4%, adjusted HR: 1.06, 95% CI: 0.49-2.29, P = 0.877). Inappropriate shocks do not affect clinical outcomes in patients implanted with an ICD, although the incidence of inappropriate shocks is high.