Changes in Higher Order Aberration After Implantable Contact Lens Implantation.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3341/jkos.2010.51.9.1210
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Se Hoon PARK
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Jung Hoon YUM
			        		
			        		;
		        		
		        		
		        		
			        		Suk Kyue CHOI
			        		
			        		;
		        		
		        		
		        		
			        		Jong Hyun LEE
			        		
			        		;
		        		
		        		
		        		
			        		Jin Hyoung KIM
			        		
			        		;
		        		
		        		
		        		
			        		Do Hyung LEE
			        		
			        		;
		        		
		        		
		        		
			        		Tae Jin KIM
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Korea. eyedr0823@hotmail.com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Higher order aberrations;
			        		
			        		
			        		
				        		Implantable contact lens
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Coma;
				        		
			        		
				        		
					        		Eye;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Lenses, Intraocular;
				        		
			        		
				        		
					        		Lotus
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Journal of the Korean Ophthalmological Society
	            		
	            		 2010;51(9):1210-1216
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:Korean
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	PURPOSE: To evaluate the changes in higher-order aberrations (HOAs) after implantation of an ICL (implantable contact lens). METHODS: Twenty-six eyes that had undergone ICL implantation between February 2008 and October 2009 were included. Ocular higher-order aberrations of all the eyes were measured using the Hartmann-Shack aberrometer (KR9000PW). Examinations were performed preoperatively, as well as one week, one month, and three months after ICL implantation. Changes in ocular total higher-order aberrations, total spherical aberration, coma aberration, trefoil aberration, and S3 and S4 calculated in the central 4-mm zone and expressed as root mean square (RMS) values were analyzed. RESULTS: The mean patient age was 25.4 years, and the mean preoperative spherical equivalent was -6.40 diopters(D). The mean postoperative spherical equivalents were 0.00 +/- 0.13D, 0.03 +/- 0.21D, -0.013 +/- 0.12D at one week, one month,and three months, respectively. There were no statistically significant differences in ocular higher-order aberration RMS,including spherical, coma, or trefoil aberration, at one week, one month, or three months postoperative or between preoperative and postoperative measurements. CONCLUSIONS: There is no significant change of ocular higher order aberration in the central 4-mm zone after ICL implantation.