Comparison of the Refractive Measurements with Hand-held Autorefractometer, Table-mounted Autorefractometer and Cycloplegic Retinoscopy in Children.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3341/kjo.2015.29.3.178
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Handan AKIL
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Soner KESKIN
			        		
			        		;
		        		
		        		
		        		
			        		Cemal CAVDARLI
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Op. Dr. Ergun Ozdemir Gorele State Hospital, Giresun, Turkey. handanakil84@gmail.com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Hand-held autorefractokeratometer;
			        		
			        		
			        		
				        		Refractive errors;
			        		
			        		
			        		
				        		Retinoscopy;
			        		
			        		
			        		
				        		Table-top autorefractokeratometer
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Child;
				        		
			        		
				        		
					        		Child, Preschool;
				        		
			        		
				        		
					        		Female;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Male;
				        		
			        		
				        		
					        		Refractive Errors/*diagnosis;
				        		
			        		
				        		
					        		*Retinoscopes;
				        		
			        		
				        		
					        		*Retinoscopy;
				        		
			        		
				        		
					        		Vision Screening
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Korean Journal of Ophthalmology
	            		
	            		 2015;29(3):178-184
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	PURPOSE: To evaluate the performance of the hand-held and table-top autorefractokeratometer in measuring refractive errors by comparing them with cycloplegic retinoscopy. METHODS: Included in the study were 112 eyes of 112 pediatric patients whose mean age was 6.78 +/- 2.61 years (range, 2 to 12 years). The refractive errors of all the eyes were measured with and without cycloplegia using a hand held autorefractokeratometer (Retinomax K-plus 3), table top autorefractokeratometer (Canon RK-F1) and performing cycloplegic retinoscopy. The spherical equivalent, cylindrical axis and keratometer values were statistically compared. RESULTS: The mean spherical equivalent obtained from the Retinomax K-plus 3 was significantly less hyperopic than that of Canon RK-F1 (p = 0.004) before cycloplegia. When the Bland Altman analysis was performed in comparisons of spherical equivalent values measured with the Retinomax K-plus 3, Canon RK-F1 and cycloplegic retinoscopy, it was seen that almost all of the differences between the measurements remained within the range of +/-2 standard deviation. Good agreement was found between Retinomax K-plus 3 and Canon RK-F1 for the Jackson cross-cylinder values at axis 0degrees and 45degrees; keratometer values respectively. CONCLUSIONS: The refractive error components were highly correlated between the two instruments and cycloplegic retinoscopy.