Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Byeong Do LEE
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Wan LEE
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Oral and Maxillofacial Radiology, School of Dentistry, Wonkwang University, Korea. eebydo@wonkwang.ac.kr
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		tomography;
			        		
			        		
			        		
				        		x-ray computed;
			        		
			        		
			        		
				        		models;
			        		
			        		
			        		
				        		anatomic;
			        		
			        		
			        		
				        		skull
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Compact Disks;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Image Processing, Computer-Assisted;
				        		
			        		
				        		
					        		Imaging, Three-Dimensional;
				        		
			        		
				        		
					        		Microcomputers;
				        		
			        		
				        		
					        		Skull
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Korean Journal of Oral and Maxillofacial Radiology
	            		
	            		 2002;32(1):27-33
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:Korean
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	PURPOSE: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model MATERIAL AND METHODS: CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works(TM) 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. RESULTS: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm(2.52%) between linear measurements of dry skull and 800 RP model. CONCLUSION: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.