Application of the EYESI binocular indirect ophthalmoscope simulation system for fundus examination skill training of general practitioner
10.3980/j.issn.1672-5123.2025.12.25
- VernacularTitle:EYESI双目间接检眼镜模拟系统在基层全科医师眼底检查技能培训的应用研究
- Author:
Lei ZHENG
1
;
Li YU
1
;
Ruyin TIAN
1
;
Qingshan CHEN
1
;
Hao LUO
1
;
Ya'nan LU
1
;
Tianhui ZHU
1
;
Kun LIU
1
;
Guoming ZHANG
1
Author Information
1. Shenzhen Eye Hospital, Shenzhen 518040, Guangdong Province, China
- Publication Type:Journal Article
- Keywords:
ophthalmology;
general practitioner;
binocular indirect ophthalmoscope;
virtual reality;
training
- From:
International Eye Science
2025;25(12):2032-2035
- CountryChina
- Language:Chinese
-
Abstract:
AIM:To evaluate the effectiveness of EYESI binocular indirect ophthalmoscope simulation system as a training platform for fundus examination skills of general practitioner.METHODS:Prospective randomized study. A total of 40 general practitioners who received clinical ophthalmology training at Shenzhen Eye Hospital from January 2021 to December 2024 were selected and randomly divided into two groups by random number table method, with 20 cases in the study group and 20 cases in the control group. The study group was trained by EYESI binocular indirect ophthalmoscope simulation system and the control group was trained by conventional teaching. Training effects of the two groups were analyzed.RESULTS: The general information of the two groups was comparable. Through training with the EYESI binocular indirect ophthalmoscope simulator, the study group showed significant improvements in total examination and drawing scores compared to pre-training results(all P<0.001). Additionally, examination duration, retinal light exposure time, and drawing time were all significantly shorter than those before training(all P<0.001).The study group achieved significantly higher total examination and drawing scores than the control group during the EYESI binocular indirect ophthalmoscope simulator assessment(all P<0.001). Furthermore, examination duration, retinal light exposure time, and drawing time were all significantly shorter in the study group compared to the control group(all P<0.001). Moreover, ratings for the novelty of the training method and overall satisfaction with the training were significantly higher in the study group than in the control group(all P<0.001); while the perceived psychological stress during training was significantly lower in the study group(P<0.001).CONCLUSION:The EYESI binocular indirect ophthalmoscope simulaton system effectively enhances both the proficiency in fundus examination skills and overall training satisfaction among general practitioners.