Comparison of Application of Home-use Mechanical Ventilator and Facility-use Mechanical Ventilator for Early Discharge of Patient from Intensive Care Units
	    		
		   		
		   			
		   		
	    	
    	 
    	10.34250/jkccn.2025.18.1.13
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Sun Young WON
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Young Hee YI
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Nursing Department, Samsung Medical Center, Seoul, South Korea
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Original Article
 
        	
        	
            
            
            	- From:
	            		
	            			Journal of Korean Critical Care Nursing
	            		
	            		 2025;18(1):13-26
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:Korean
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 Purpose:: This study aimed to identify and compare the effects of home-use mechanical ventilator (MV) and facility-use mechanical ventilator on early discharge from the intensive care units (ICUs).  
				        	
				        
				        	Methods:: This retrospective study used data from the electronic medical records of 290 patients who underwent MV in the ICU of a tertiary general hospital in Seoul.  
				        	
				        
				        	Results:: Significant differences were observed in the length of ICU stay, total number of days of MV application, and length of hospital stay. The length of ICU stay was 30.00±28.14 days in the home-use MV group and 23.74±18.24 days in the facility-use MV group for facility-use (t=2.25, p=.026). The total number of days of MV application in ICU was 24.44±21.86 days in the home-use MV group and 19.35±14.25 days in the facility-use MV group (t=2.35, p=.020). The length of hospital stay was 101.88± 141.81 days in the home-use MV group and 74.24±71.38 days in the facility-use MV group (t=2.10, p=.037). The readmission rates within 72 hours of discharge from the ICU were 2.1% and 2.1%, respectively.  
				        	
				        
				        	Conclusion:: A facility-use ventilator shortens the length of ICU stay and the total number of days of MV application in the ICU compared with a home-use mechanical ventilator, and it can be safely used for early discharge of patients from the ICU.