Abstract:
This article reports the clinica diagnosis and treatment of a 66-year-old male patient with elevated free thyroxine(FT 4) following coronavirus disease 2019(COVID-19) infection. The thyroid function tests showed a significant increase in FT 4, while thyroid stimulating hormone(TSH) was not suppressed. Re-testing on different platforms revealed inconsistent FT 4 elevations, indicating potential interference in FT 4 measurement. Radioimmunoprecipitation assays confirmed the presence of anti-thyroxine autoantibodies(T 4Ab) in the patient′s body, specifically the IgM subtype. This article reviews relevant literature, focusing on the identification and differential diagnosis of thyroid hormone autoantibodies interference.