The progress in dosimetric evaluation methods for 90Y microspheres radioembolization
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.cn112271-20240418-00142
   		
        
        	
        		- VernacularTitle:90Y微球放射性栓塞治疗的剂量估算方法进展
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hongming LIU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Rui QIU
			        		
			        		;
		        		
		        		
		        		
			        		Junli LI
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 清华大学工程物理系 粒子技术与辐射成像教育部重点实验室,北京 100084
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		90Y microsphere;
			        		
			        		
			        		
				        		Dosimetry evaluation methods;
			        		
			        		
			        		
				        		Radioembolization
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Radiological Medicine and Protection
	            		
	            		 2024;44(9):809-818
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	90Y microspheres radioembolization therapy is an emerging interventional technique used for the treatment and palliative care of intermediate and advanced liver cancer, which was registered by National Medical Products Administration for imported drugs in 2022. In order to improve the tumor response rate and reduce toxic effects, the dose assessment for the tumor and healthy tissues is implemented throughout treatment. The efficiency and accuracy of estimation method are the keys to improving the therapeutic effect. This article investigated and summarized six evaluation method and their latest progress, discussed the unique advantages and applicable scenarios of each methods, and explored the possible challenges faced in clinical applications. This study would support the development and standardization of dose prediction and evaluation in radioembolization with 90Y microspheres.