Analysis of interference effect of nitrites on total urinary protein assay by pyrogallol red molybdenum method
	    		
		   		
		   			
		   		
	    	
    	 
    	10.13602/j.cnki.jcls.2024.04.01
   		
        
        	
        		- VernacularTitle:亚硝酸盐对焦酚红法检测24h尿液总蛋白的干扰分析
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Fan YANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Danfeng DONG
			        		
			        		;
		        		
		        		
		        		
			        		Tongxuan SU
			        		
			        		;
		        		
		        		
		        		
			        		Yide LU
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 上海交通大学医学院附属瑞金医院检验科,上海 200025
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		24 h urine total protein;
			        		
			        		
			        		
				        		nitrite;
			        		
			        		
			        		
				        		interference analysis;
			        		
			        		
			        		
				        		vitamin C;
			        		
			        		
			        		
				        		correction test
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Clinical Laboratory Science
	            		
	            		 2024;42(4):241-245
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To investigate the interference effect of nitrite on the determination of 24 h urine total protein by pyrogallol red method and evaluate the feasibility of using vitamin C to correct this interference.Methods According to the CLSI EP7-A3 document,fresh urine specimens with 24 h urine total protein concentrations of 150 mg/L,500 mg/L and 1 000 mg/L were selected as control samples,and interfering samples containing different concentrations of sodium nitrite were prepared.The interference of nitrite was con-firmed through paired difference experiments,and the relationship between nitrite concentration and interference level was clarified u-sing dose-effect experiments.The effects of different concentrations of vitamin C on correcting the interference caused by 200 μg/mL so-dium nitrite were evaluated.Additionally,61 nitrite-positive and 40 nitrite-negative clinical specimens were collected to compare the relative differences before and after vitamin C correction to assess its clinical application value.Results In the paired difference exper-iments,200 μg/mL sodium nitrite had relative interferences of-157.8%and-36.2%on the determination of urine total protein of 150 mg/L and 500 mg/L respectively,which were significantly greater than 1/2TEa(22%).Although there was a-20.5%negative interference for the high concentration of 1 000 mg/L urine total protein,the interference was within the acceptable range.The dose-effect experiment results showed that as the nitrite concentration in urine increased,the negative interference on urine total protein de-tection also gradually increased.In the presence of 200 μg/mL sodium nitrite as the final concentration,the addition of 0.2 mg/mL vi-tamin C corrected the urine total protein at 150 mg/L and 500 mg/L to 148 mg/L(-1.1%)and 402 mg/L(-19.5%),respectively,both within the acceptable range.The relative differences produced by vitamin C correction in the nitrite-positive clinical specimen group were significantly higher than those in the nitrite-negative group(P<0.01).Conclusions Nitrite produced negative interference on the determination of urine total protein by the pyrogallol red method,especially when the urine total protein is 150 mg/L,which needs attention of clinical laboratories.The addition of 0.2 mg/mL vitamin C could effectively correct the interference of nitrite in low-concentration of urine total protein specimens,showing potential clinical application value.