Application of infrared scanning temperature gun in geriatrics department
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/j.issn.1674-2907.2015.07.040
   		
        
        	
        		- VernacularTitle:红外线扫温枪在老年科的应用
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Li? ZHANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yingjie FENG
			        		
			        		;
		        		
		        		
		        		
			        		Sumei FAN
			        		
			        		;
		        		
		        		
		        		
			        		Suhua YANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 223002 徐州医学院附属淮安医院老年科
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Thermometer;
			        		
			        		
			        		
				        		Temperature;
			        		
			        		
			        		
				        		Geriatrics;
			        		
			        		
			        		
				        		Infrared scanning temperature gun
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Modern Nursing
	            		
	            		 2015;21(7):853-855
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To explore the effect of infrared scanning temperature gun in geriatrics department. Methods A total of 200 cases of elderly patients were divided into control group with mercury thermometer ( armpit) and the test group with infrared scanning temperature gun ( armpit,mild forehead, neck, neiguan) . The time of measuring temperature and sterilization, and the effects on measuring temperature were compared. Results The time of measuring temperature and sterilization in the test group were (0. 1 ± 0. 0) and (0. 5 ± 0. 0 ) min, which were significantly shorter than those of the control group ( t = 20. 61, 49. 71, respectively;P<0. 01). There was a significant difference in the forehead temperature measured by infrared scanning temperature gun and the armpit temperature measured by mercury thermometer (P<0. 05). However, there was no significant difference in the armpit, neck and neiguan temperature measured by infrared scanning temperature gun and the armpit temperature measured by mercury thermometer (P>0. 05). Patients and nurses were more likely to the neck and neiguan measuring by infrared scanning temperature gun. Conclusions The stability and accuracy of infrared scanning temperature gun measuring neck and neiguan is same as the mercury thermometer.