Effect of the infusion management system on the nursing risk factors in ICU
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/j.issn.1674-2907.2014.21.003
   		
        
        	
        		- VernacularTitle:输液治疗管理系统对ICU护理高危因素的影响
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Bo XU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Biling YE
			        		
			        		;
		        		
		        		
		        		
			        		Weizheng HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Niannian WU
			        		
			        		;
		        		
		        		
		        		
			        		Suzhen WAN
			        		
			        		;
		        		
		        		
		        		
			        		Wenji LIN
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 518067 深圳市蛇口人民医院ICU
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		ICU;
			        		
			        		
			        		
				        		Infusion management system;
			        		
			        		
			        		
				        		Unplanned extubation;
			        		
			        		
			        		
				        		Vasoactive drug
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Modern Nursing
	            		
	            		 2014;20(21):2600-2602
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To explore the application of the infusion management system in ICU and its effect on the major nursing risk factors .Methods One hundred and five patients with top ten diseases in ICU from March 2013 to December 2013 were chosen and were randomly divided into the control group ( n=50 ) and the observation group ( n =55 ) .The control group received the management of liquid therapy through the monomer infusion pump , and the observation group received the management of liquid therapy through B .Braun infusion therapy system .The average time of liquid therapy , the rate of unplanned extubation , the error rate of vasoactive drugs and the nurses ’ satisfaction of two groups were observed .Results The average time of liquid therapy, the rate of unplanned extubation , the error rate of vasoactive drugs and the nurses ’ satisfaction were respectively (65.3 ±21.4)h, 7.3%, 7.3%, 92.7%in the observation group, and were better than (99.4 ± 27.8)h, 16.0%, 14.0%, 56.0% in the control group, and the differences were statistically significant (t/χ2 =2.63, 7.25, 5.38, 8.68, respectively;P<0.05).Conclusions Application of B.Braun infusion therapy system in ICU can reduce the workload of nurses , and decrease the rate of unplanned extubation and the error rate of vasoactive drugs in patients , and increase the nurses ’ satisfaction.