Application of Imaging-Guided Radiation Therapy in Pelvic Tumor Radiotherapy
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1671-7104.2015.04.018
   		
        
        	
        		- VernacularTitle:图像引导放射治疗在盆腔肿瘤放疗中的应用研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Bing WU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Junxiang HE
			        		
			        		;
		        		
		        		
		        		
			        		Jingguo FU
			        		
			        		;
		        		
		        		
		        		
			        		Changli RUAN
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 武汉大学人民医院肿瘤中心
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		IGRT;
			        		
			        		
			        		
				        		pelvic cancer;
			        		
			        		
			        		
				        		setup errors
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Medical Instrumentation
	            		
	            		 2015;(4):299-301
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To discuss the influence of setup errors on the accuracy of pelvic cancer in IGRT, analysis setup errors and determine the CTV-to-PTV margins. Methods 60 pelvic cancer patients treated with Varian 23IX, al of them were performed by CBCT before and after-correction three times in the first week and after that once a week. Then, to measure the setup errors at X(left-right), Y(superior-inferior), Z(anterior-posterior) axis and E(coronal), F(sagittal), G(axial) rotation directions. Results 530 scans obtained in al , the setup errors in X, Y, Z, E, F, G were (-0.52±4.18) mm, (0.73±4.86) mm, (-0.36±3.62)mm, (0.14±1.20)o, (0.13±1.34)o, (0.21±1.73)o respectively and were much lower after correction at X, Y, Z axis, besides, CTV-to-PTV margins decrease a lot. Conclusion The accuracy of radiotherapy can be highly increased with the use of IGRT in pelvic cancer.