Reliability of ultrasound in the assessment of diaphragm function/
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1001-1242.2024.01.011
   		
        
        	
        		- VernacularTitle:超声在膈肌功能评估中的信度研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Lingjun XIAO
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Wenjing SUN
			        		
			        		;
		        		
		        		
		        		
			        		Lexin BAN
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 中山大学孙逸仙纪念医院康复医学科,广东省广州市,510120
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		ultrasound;
			        		
			        		
			        		
				        		diaphragm;
			        		
			        		
			        		
				        		the reliability
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Rehabilitation Medicine
	            		
	            		 2024;39(1):76-81
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To analyze the consistency and repeatability of ultrasonography in diaphragm function evaluation. Method:Sixty healthy subjects participated in the present study,using a PA12A portable color doppler untra-sound diagnostic system.The diaphragm data were recorded during calm breathing and deep breathing,includ-ing diaphragm muscle mobility during calm breathing and deep breathing,diaphragmatic thickness during calm exhalation and calm inspiration,and diaphragmatic thickness during deep exhalation and deep inspiration.The in-tra-test reliability,inter-tester reliability and retest reliability of the above indexes were analyzed respectively. Result:For intra-test reliability,the intra-class correlation coefficient(ICC)values for diaphragm muscle mo-bility during calm breathing,diaphragm muscle mobility during deep breathing,diaphragmatic thickness during calm exhalation,diaphragmatic thickness during calm inspiration,diaphragmatic thickness during maximal exha-lation and diaphragmatic thickness during maximal inspiration were 0.99,0.99,0.99,0.99,0.99,0.99 and 0.99,respectively.The ICC values for the six indicators were 0.84,0.80,0.82,0.82,0.83,and 0.77 for in-ter-tester reliability.For retest reliability,the ICC values for the six indicators were 0.98,0.86,0.98,0.97,0.94,and 0.86 for relative reliability.The standard error of measurement(SEM)for the absolute reliability of the six indicators were 0.09,0.39,0.01,0.02,0.02,0.03,SEM%were 5.23%,8.40%,5.38%,5.7%,8.17%,8.77%,and the minimal detectable change(MDC)were 0.25,1.08,0.03,0.04,0.04,0.09,and MDC%were 14.49%,23.28%,14.9%,15.8%,22.64%,24.31%,respectively.Bland-Altman graphical analy-sis showed no systematic errors. Conclusion:Ultrasound has good reliability in diaphragm function evaluation and can provide objective evi-dence in clinical application.