Application of pressure-controlled ventilation-volume guaranteed ventilation mode in neonatal thora-coscopic esophageal atresia surgery
10.12089/jca.2024.02.009
- VernacularTitle:压力控制容量保证通气模式在新生儿胸腔镜食管闭锁手术中的应用
- Author:
Haikou YANG
1
;
Qiang QIANG
;
Shisan ZHOU
;
Hao ZHANG
;
Jian SUN
Author Information
1. 223002 江苏省淮安市妇幼保健院麻醉科
- Keywords:
Esophageal atresia;
Thoracoscope;
Pressure-controlled ventilation-volume guaranteed;
Volume-controlled ventilation;
Neonate;
One-lung ventilation
- From:
The Journal of Clinical Anesthesiology
2024;40(2):155-159
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the ventilation effect and application safety of pressure-con-trolled ventilation-volume guaranteed(PCV-VG)mode in neonatal thoracoscopic esophageal atresia surgery.Methods Thirty-six newborns who underwent thoracoscopic esophageal atresia surgery under general anes-thesia,22 males and 14 females,aged 1-4 days,weighing 1.4-4.5 kg,ASA physical status Ⅲ or Ⅳ,were divided into two groups using a random number table method:the PCV-VG mode group(group P)and the volume-controlled ventilation(VCV)mode group(group V),18 newborns in each group.After anes-thesia,PCV-VG and VCV ventilation modes were employed for mechanical ventilation in groups P and V,respectively.The MAP,HR,and SpO2 were recorded prior to tracheal intubation,10 minutes before one-lung ventilation(OLV),30 minutes after OLV,and 10 minutes after completion of OLV.Additionally,the Pmean,Ppeak,Pplat,Cdyn,PETCO2,PaCO2,PaO2,and pH were monitored 10 minutes before OLV,30 minutes after OLV,and 10 minutes after completion of OLV.The time of tracheal tube removal after surgery and the duration of ICU retention were also observed.Results Compared with group V,the SpO2,Cdyn,PaO2,and pH levels showed a significant increase,while significant decrease were noted in Pmean,Ppeak,and Pplat in group P 30 minutes after OLV(P<0.05).Compared with group V,the PETCO2 and PaCO2 in group P decreased significantly 30 minutes after OLV and 10 minutes after completion of OLV.Be-sides,compared with group V,the time of tracheal tube removal after surgery and the duration of ICU reten-tion were also significantly shortened in group P(P<0.05).Conclusion The utilization of PCV-VG ven-tilation mode in neonatal thoracoscopic esophageal atresia surgery,as compared to VCV ventilation mode,can effectively reduce airway pressure,enhance lung compliance,optimize intraoperative lung gas exchange,and facilitate postoperative recovery of the neonates.