Accuracy of four formulas in predicting diopter of intraocular lens implanted in high myopia cataract eyes
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3980/j.issn.1672-5123.2024.4.27
   		
        
        	
        		- VernacularTitle:四种人工晶状体屈光度计算公式预测高度近视白内障人工晶状体屈光度的准确性
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Wei QIU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Qingquan WEI
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yingying GONG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yanyun JIANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Ophthalmology, Tongren Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200336, China
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		cataract;
			        		
			        		
			        		
				        		calculation of intraocular lens power;
			        		
			        		
			        		
				        		IOL Master 700;
			        		
			        		
			        		
				        		high myopia;
			        		
			        		
			        		
				        		accuracy
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			International Eye Science
	            		
	            		 2024;24(4):641-645
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	 AIM: To evaluate the accuracy of the formulas, including Haigis, SRK/T, Holladay 1, and Holladay 2, in predicting the diopter of the intraocular lens implanted in high myopia cataract patients.METHODS: Prospective study. A total of 168 cases(168 eyes)of age-related cataract with an axial length(AL)≥26 mm who were treated in our hospital from August 2017 to November 2021 were selected. According to the preoperative AL measured by IOL Master 700, the patients were divided into five groups, including 37 cases(37 eyes)in group A with 26 mm≤AL<27 mm, 34 cases(34 eyes)in group B with 27 mm≤AL<28 mm, 42 cases(42 eyes)in group C with 28 mm≤AL<29 mm, 28 cases(28 eyes)in group D with 29 mm≤AL<30 mm, and 27 patients(27 eyes)in group E with AL ≥ 30 mm. Subjective refraction was performed at 3 mo postoperatively, and the mean numerical error(MNE)and mean absolute error(MAE)of each formula for predicting diopters were calculated.RESULTS: The MNE and MAE of the Haigis and Holladay 2 formulas were relatively less in each group, and MNE and MAE did not significantly increase with the growth of the axial length. However, the MAE and MNE of the SRK/T and Holladay 1 formulas significantly increased with the growth of the axial length, with the MNE and MAE of the Holladay 1 formula increasing more significantly in groups C, D, and E.CONCLUSION: For patients with age-related cataract, with an axial length of ≥26 mm, the accuracy of predicting the diopter of the intraocular lens using the Haigis and Holladay 2 formulas were higher.