Application of thrombelastogram in blood transfusion for patients in early stage of severe trauma
10.13303/j.cjbt.issn.1004-549x.2023.12.013
- VernacularTitle:血栓弹力图在严重创伤后早期入院患者临床用血的应用
- Author:
Xiaoming LI
1
;
Xiuqun DUAN
1
;
Wei ZHANG
1
Author Information
1. Ezhou Central Hospital, Ezhou 436000, China
- Publication Type:Journal Article
- Keywords:
thrombelastogram(TEG);
clinical blood use;
severe trauma
- From:
Chinese Journal of Blood Transfusion
2023;36(12):1136-1139
- CountryChina
- Language:Chinese
-
Abstract:
【Objective】 To explore the value of thrombelastogram(TEG) on monitoring the coagulation function and guiding blood transfusion in admitted patients in early stage of severe trauma. 【Methods】 A total of 96 patients in early stage of severe trauma were selected from Ezhou Central Hospital, and were divided into two groups using a random number table method, with 48 patients in each group. The control group was guided by four routine coagulation tests for blood transfusion, while the observation group was guided by TEG.The detection rate of trauma-induced coagulopathy, detection duration, blood infusion volume within 24 hours of admission, coagulation index levels at different time points after blood transfusion, length of hospital stay, ICU stay, and mortality rate between the two groups were compared. 【Results】 The detection rate of trauma-induced coagulopathy was 72.9% in the control group and 93.8% in the observation group(P<0.05). The transfusion volume of fresh frozen plasma (U) and red blood cell (U) in the observation group within 24 hours of admission were significantly lower than those in the control group, which were (35.13±4.75) vs (45.17±6.54), (5.19±1.41) vs (7.08±1.32) (P<0.05); the tranfusion volume of cryoprecipitate (U) and the rate of platelet transfusion in the observation group were significantly higher than those in the control group, which were (36.78±2.49) vs (24.84±3.92), 79.2% vs 22.9%(P<0.05). The APTT(s), PT(s), TT(s), R(min), and K(min) in the observation group 8 hours after blood transfusion were significantly lower than those in the control group, which were (58.16±10.39) vs (70.83±14.99), (15.44±3.22) vs (17.32±2.89), (21.39±4.51) vs (25.18±4.73), (13.03±3.29) vs (14.95±4.57), and (8.07±3.65) vs (10.54±5.14) (P<0.05), while FIB(g/L), MA(mm), α(°), and Plt (×109/L) were higher than those in the control group, which were (2.02±0.46) vs (1.09±0.27), (35.56±11.88) vs (29.57±9.25), (40.07±13.34) vs (27.23±10.87), and (135.87±59.13) vs (108.17±52.08) (P<0.05). 【Conclusion】 TEG can help monitoring the coagulation function in patients in early stage of severe trauma and guide the blood transfusion.