1.The application of porous polyethylene biological scaffolds combined with temporoparietal fascial flaps in auricular reconstruction.
Ken LIN ; Yulin DU ; Rui HUANG ; Xia LI ; Hangying ZHANG ; Yuhui HUA ; Dong SU ; Jing MA
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(2):147-157
Objective:To analyze the application efficacy of employing high-density porous polyethylene (Su-por) in combination with temporoparietal fascial flaps via a minimally invasive scalp incision in auricular reconstruction. Methods:This study carried out a retrospective analysis of 50 patients (50 ears in total) who underwentprimary auricular reconstruction with a Su-por scaffold in our hospital from June 2022 to January 2024. All patients underwent primary auricular reconstruction using a minimally invasive scalp incision with high-density porous polyethylene (Su-por) and temporoparietal fascial flaps. The postoperative treatment effects and complications were statistically analyzed. Results:The reconstructed ears of all patients survived. After 6 months of follow-up, the scar hyperplasia of the scalp minimally invasive incision was not obvious in any patient, and no significant hair loss was observed. The reconstructed auricle of 48 patients had a realistic shape and strong three-dimensional sense. With the extension of follow-up time, the three-dimensional structure of the auricle became clearer, and patient satisfaction increased. Among the remaining two patients, one case of flap necrosis survived after skin grafting and dressing changes. One patient had scar hyperplasia at the incision of the reconstructed ear due to a scar-prone constitution, and the shape of the auricle was not ideal, but the scar hyperplasia at the scalp incision was not obvious. Conclusion:One-stage ear reconstruction with high-density porous polyethylene (Su-por) combined with superficial temporal fascia flap through a minimally invasive scalp incision can better show the fine structure of the reconstructed ear. The minimally invasive scalp incision can effectively reduce the occurrence of scar hyperplasia and postoperative alopecia at the scalp incision.
Humans
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Surgical Flaps
;
Tissue Scaffolds
;
Polyethylene
;
Ear Auricle/surgery*
;
Male
;
Scalp/surgery*
;
Female
;
Skin Transplantation
;
Fascia/transplantation*
;
Porosity
;
Adult
;
Middle Aged
2.A study on the predictive model of porous hyperelastic properties of human alveolar bone based on computed tomography imaging.
Bin WU ; Mingna LI ; Fan YANG ; Le YUAN ; Yi LU ; Di JIANG ; Yang YI ; Bin YAN
Journal of Biomedical Engineering 2025;42(2):359-365
Alveolar bone reconstruction simulation is an effective means for quantifying orthodontics, but currently, it is not possible to directly obtain human alveolar bone material models for simulation. This study introduces a prediction method for the equivalent shear modulus of three-dimensional random porous materials, integrating the first-order Ogden hyperelastic model to construct a computed tomography (CT) based porous hyperelastic Ogden model (CT-PHO) for human alveolar bone. Model parameters are derived by combining results from micro-CT, nanoindentation experiments, and uniaxial compression tests. Compared to previous predictive models, the CT-PHO model shows a lower root mean square error (RMSE) under all bone density conditions. Simulation results using the CT-PHO model parameters in uniaxial compression experiments demonstrate more accurate prediction of the mechanical behavior of alveolar bone under compression. Further prediction and validation with different individual human alveolar bone samples yield accurate results, confirming the generality of the CT-PHO model. The study suggests that the CT-PHO model proposed in this paper can estimate the material properties of human alveolar bone and may eventually be used for bone reconstruction simulations to guide clinical treatment.
Humans
;
Tomography, X-Ray Computed/methods*
;
Porosity
;
Alveolar Process/physiology*
;
Bone Density
;
Computer Simulation
;
Elasticity
;
X-Ray Microtomography
;
Stress, Mechanical
;
Finite Element Analysis
;
Models, Biological
3.Simulation research on the influence of regular porous lattice scaffolds on bone growth.
Yutao MEN ; Lele WEI ; Baibing HU ; Pujun HAO ; Chunqiu ZHANG
Journal of Biomedical Engineering 2025;42(4):808-816
To assess the implantation effectiveness of porous scaffolds, it is essential to consider not only their mechanical properties but also their biological performance. Given the high cost, long duration and low reproducibility of biological experiments, simulation studies as a virtual alternative, have become a widely adopted and efficient evaluation method. In this study, based on the secondary development environment of finite element analysis software, the strain energy density growth criterion for bone tissue was introduced to simulate and analyze the cell proliferation-promoting effects of four different lattice porous scaffolds under cyclic compressive loading. The biological performance of these scaffolds was evaluated accordingly. The computational results indicated that in the early stages of bone growth, the differences in bone tissue formation among the scaffold groups were not significant. However, as bone growth progressed, the scaffold with a porosity of 70% and a pore size of 900 μm demonstrated markedly superior bone formation compared to other porosity groups and pore size groups. These results suggested that the scaffold with a porosity of 70% and a pore size of 900 μm was most conducive to bone tissue growth and could be regarded as the optimal structural parameter for bone repair scaffold. In conclusion, this study used a visualized simulation approach to pre-evaluate the osteogenic potential of porous scaffolds, aiming to provide reliable data support for the optimized design and clinical application of implantable scaffolds.
Tissue Scaffolds/chemistry*
;
Porosity
;
Finite Element Analysis
;
Tissue Engineering/methods*
;
Computer Simulation
;
Bone Development
;
Osteogenesis
;
Humans
;
Cell Proliferation
4.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
5.Clinical application of mineralized collagen scaffolds in surgical treatment of skull defects.
Tuoyu CHEN ; Shuo WANG ; Bo LI ; Kaiyuan YANG ; Weitao MAN ; Xiumei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(12):1427-1432
OBJECTIVE:
To explore the clinical application value of mineralized collagen (MC) bone scaffolds in repairing various types of skull defects, and to assess the suitability and repair effectiveness of porous MC (pMC) scaffolds, compact MC (cMC) scaffolds, and biphasic MC composite (bMC) scaffolds.
METHODS:
A retrospective analysis was conducted on the clinical data of 105 patients who underwent skull defect repair with pMC, cMC, or bMC between October 2014 and April 2022. The cohort included 63 males and 42 females, ranging in age from 3 months to 55 years, with a median age of 22.7 years. Causes of defects included craniectomy after traumatic surgery in 37 cases, craniotomy in 58 cases, tumor recurrence or intracranial hemorrhage surgery in 10 cases. Appropriate MC scaffolds were selected based on the patient's skull defect size and age: 58 patients with defects <3 cm² underwent skull repair with pMC (pMC group), 45 patients with defects ≥3 cm² and aged ≥5 years underwent skull repair with cMC (cMC group), and 2 patients with defects ≥3 cm² and aged <5 years underwent skull repair with bMC (bMC group). Postoperative clinical follow-up and imaging examinations were conducted to evaluate bone regeneration, the biocompatibility of the repair materials, and the occurrence of complications.
RESULTS:
All 105 patients were followed up 3-24 months, with an average of 13 months. No material-related complication occurred in any patient, including skin and subcutaneous tissue infection, excessive ossification, and rejection. CT scans at 6 months postoperatively showed bone growth in all patients, and CT scans at 12 months postoperatively showed complete or near-complete resolution of bone defects in all patients, with 58 cases repaired in the pMC group. The CT values of the defect site and the contralateral normal skull bone in the pMC group at 12 months postoperatively were (1 123.74±93.64) HU and (1 128.14±92.57) HU, respectively, with no significant difference ( t=0.261, P=0.795).
CONCLUSION
MC exhibits good biocompatibility and osteogenic induction ability in skull defect repair. pMC is suitable for repairing small defects, cMC is suitable for repairing large defects, and bMC is suitable for repairing pediatric skull defects.
Humans
;
Tissue Scaffolds
;
Male
;
Female
;
Collagen
;
Retrospective Studies
;
Adult
;
Child
;
Adolescent
;
Middle Aged
;
Child, Preschool
;
Skull/surgery*
;
Young Adult
;
Infant
;
Plastic Surgery Procedures/methods*
;
Tissue Engineering/methods*
;
Craniotomy/methods*
;
Bone Regeneration
;
Treatment Outcome
;
Porosity
;
Biocompatible Materials
6.Natural-derived porous nanocarriers for the delivery of essential oils.
Hongxin CHEN ; Xiaoyu SU ; Yijuan LUO ; Yan LIAO ; Fengxia WANG ; Lizhen HUANG ; Aiguo FAN ; Jing LI ; Pengfei YUE
Chinese Journal of Natural Medicines (English Ed.) 2024;22(12):1117-1133
Essential oils (EOs) are natural, volatile substances derived from aromatic plants. They exhibit multiple pharmacological effects, including antibacterial, anticancer, anti-inflammatory, and antioxidant properties, with broad application prospects in health care, food, and agriculture. However, the instability of volatile components, which are susceptible to deterioration under light, heat, and oxygen exposure, as well as limited water solubility, have significantly impeded the development and application of EOs. Porous nanoclays are natural clay minerals with a layered structure. They possess unique structural characteristics such as large pore size, regular distribution, and tunable particle size, which are extensively utilized in drug delivery, adsorption separation, reaction catalysis, and other fields. Natural-derived porous nanoclays have garnered considerable attention for the encapsulation and delivery of EOs. This review comprehensively summarizes the structure, types, and properties of natural-derived porous nanoclays, focusing on the structural characteristics of porous nanoclays such as montmorillonite, palygorskite, halloysite, kaolinite, vermiculite, and natural zeolite. It also examines research advances in their delivery of EOs and explores engineering strategies to enhance the delivery of EOs by natural-derived porous nanoclays. Finally, various applications of natural-derived porous nanoclays for EOs in antibacterial, food preservation, repellent, and insecticide aspects are presented, providing a reference for the development and application of EOs.
Humans
;
Nanoparticles/chemistry*
;
Oils, Volatile/administration & dosage*
;
Porosity
;
Nanoparticle Drug Delivery System/chemistry*
7.Advances in enzyme immobilization based on hierarchical porous metal-organic frameworks.
Yawei CHEN ; Huijie ZHENG ; Yiting CAO ; Jiajia YANG ; Huiyun ZHOU
Chinese Journal of Biotechnology 2023;39(3):930-941
As an excellent hosting matrices for enzyme immobilization, metal-organic framework (MOFs) provides superior physical and chemical protection for biocatalytic reactions. In recent years, the hierarchical porous metal-organic frameworks (HP-MOFs) have shown great potential in enzyme immobilization due to their flexible structural advantages. To date, a variety of HP-MOFs with intrinsic or defective porous have been developed for the immobilization of enzymes. The catalytic activity, stability and reusability of enzyme@HP-MOFs composites are significantly enhanced. This review systematically summarized the strategies for developing enzyme@HP-MOFs composites. In addition, the latest applications of enzyme@HP-MOFs composites in catalytic synthesis, biosensing and biomedicine were described. Moreover, the challenges and opportunities in this field were discussed and envisioned.
Metal-Organic Frameworks/chemistry*
;
Porosity
;
Enzymes, Immobilized/chemistry*
;
Biocatalysis
;
Catalysis
8.Effect of pH on the chelation between strontium ions and decellularized small intestinal submucosal sponge scaffolds.
Yu Ke LI ; Mei WANG ; Lin TANG ; Yu Hua LIU ; Xiao Ying CHEN
Journal of Peking University(Health Sciences) 2023;55(1):44-51
OBJECTIVE:
To investigate the preparation of decellularized small intestinal submucosa (dSIS) sponge scaffolds with chelated strontium (Sr) ions at different pH values, and to select the appropriate pH values for synthesizing Sr/dSIS scaffolds using the physicochemical properties and biocompatibility of the scaffolds as evaluation indexes.
METHODS:
(1) Sr/dSIS scaffolds preparation and grouping: After mixing dSIS solution and strontium chloride solution in equal volumes, adjusting pH of the solution to 3, 5, 7, and 9 respectively, porous scaffolds were prepared by freeze-drying method after full reaction at 37℃, which were named Sr/dSIS-3, -5, -7, and -9 respectively, and the dSIS scaffolds were used as the control group. (2) Physicochemical property evaluation: The bulk morphology of the scaffolds was observed in each group, the microscopic morphology analyzed by scanning electron microscopy, and the porosity and pore size determined, the surface elements analyzed by energy spectroscopy, the structure of functional groups analyzed by infrared spectroscopy, the chelation rate determined by atomic spectrophotometry, the water absorption rate detected by using specific gravity method, and the compression strength evaluated by universal mechanical testing machine.(3) Biocompatibility evaluation: The cytotoxicity and proliferative effect to bone mesenchymal stem cells (BMSCs) of each group were evaluated by Calcein-AM/PI double staining method.
RESULTS:
Scanning electron microscopy showed that the scaffolds of each group had an interconnected three-dimensional porous structure with no statistical difference in pore size and porosity. Energy spectrum analysis showed that strontium could be detected in Sr/dSIS-5, -7 and -9 groups, and strontium was uniformly distributed in the scaffolds. Functional group analysis further supported the formation of chelates in the Sr/dSIS-5, -7 and -9 groups. Chelation rate analysis showed that the Sr/dSIS-7 group had the highest strontium chelation rate, which was statistically different from the other groups (P < 0.05). The scaffolds in all the groups had good water absorption. The scaffolds in Sr/dSIS-5, -7 and -9 groups showed significantly improved mechanical properties compared with the control group (P < 0.05). The scaffolds in all the groups had good biocompatibility, and the Sr/dSIS-7 group showed the best proliferation of BMSCs.
CONCLUSION
When pH was 7, the Sr/dSIS scaffolds showed the highest strontium chelation rate and the best proliferation effect of BMSCs, which was the ideal pH value for the preparation of the Sr/dSIS scaffolds.
Tissue Scaffolds/chemistry*
;
Biocompatible Materials
;
Strontium/pharmacology*
;
Ions
;
Hydrogen-Ion Concentration
;
Tissue Engineering/methods*
;
Porosity
9.Preparation and properties of silica/hydroxyapatite whiskers porous ceramics scaffold.
Yuxi WAN ; Qiangguo CHEN ; Tingting YAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1142-1148
OBJECTIVE:
To investigate the preparation and properties of the novel silica (SiO 2)/hydroxyapatite (HAP) whiskers porous ceramics scaffold.
METHODS:
The HAP whiskers were modified by the SiO 2 microspheres using the Stöber method. Three types of SiO 2/HAP whiskers were fabricated under different factors (for the No.1 samples, the content of tetraethoxysilane, stirring time, calcination temperature, and soaking time were 10 mL, 12 hours, 560℃, and 0.5 hours, respectively; and in the No.2 samples, those were 15 mL, 24 hours, 650℃, and 2 hours, respectively; while those in the No.3 samples were 20 mL, 48 hours, 750℃, and 4 hours, respectively). The phase and morphology of the self-made HAP whisker and 3 types of SiO 2/HAP whiskers were detected by the X-ray diffraction analysis and scanning electron microscopy. Taken the self-made HAP whisker and 3 types of SiO 2/HAP whiskers as raw materials, various porous ceramic materials were prepared using the mechanical foaming method combined with extrusion molding method, and the low-temperature heat treatment. The pore structure of porous ceramics was observed by scanning electron microscopy. Its porosity and pore size distribution were measured. And further the axial compressive strength was measured, and the biodegradability was detected by simulated body fluid. Cell counting kit 8 method was used to conduct cytotoxicity experiments on the extract of porous ceramics.
RESULTS:
The SiO 2 microspheres modified HAP whiskers and its porous ceramic materials were prepared successfully, respectively. In the SiO 2/HAP whiskers, the amorphous SiO 2 microspheres with a diameter of 200 nm, uniform distribution and good adhesion were attached to the surface of the whiskers, and the number of microspheres was controllable. The apparent porosity of the porous ceramic scaffold was about 78%, and its pore structure was composed of neatly arranged longitudinal through-holes and a large number of micro/nano through-holes. Compared with HAP whisker porous ceramic, the axial compressive strength of the SiO 2/HAP whisker porous ceramics could reach 1.0 MPa, which increased the strength by nearly 4 times. Among them, the axial compressive strength of the No.2 SiO 2/HAP whisker porous ceramic was the highest. The SiO 2 microspheres attached to the surface of the whiskers could provide sites for the deposition of apatite. With the content of SiO 2 microspheres increased, the deposition rate of apatite accelerated. The cytotoxicity level of the prepared porous ceramics ranged from 0 to 1, without cytotoxicity.
CONCLUSION
SiO 2/HAP whisker porous ceramics have good biological activity, high porosity, three-dimensional complex pore structure, good axial compressive strength, and no cytotoxicity, which make it a promising scaffold material for bone tissue engineering.
Animals
;
Durapatite
;
Porosity
;
Vibrissae
;
Apatites
;
Ceramics
;
Silicon Dioxide
10.Research progress in influence of microstructure on performance of triply-periodic minimal surface bone scaffolds.
Yadi SUN ; Jianxiong MA ; Yan WANG ; Benchao DONG ; Peichuan YANG ; Yan LI ; Yiyang LI ; Liyun ZHOU ; Jiahui SHEN ; Xinlong MA
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1314-1318
OBJECTIVE:
To summarize the influence of microstructure on performance of triply-periodic minimal surface (TPMS) bone scaffolds.
METHODS:
The relevant literature on the microstructure of TPMS bone scaffolds both domestically and internationally in recent years was widely reviewed, and the research progress in the imfluence of microstructure on the performance of bone scaffolds was summarized.
RESULTS:
The microstructure characteristics of TPMS bone scaffolds, such as pore shape, porosity, pore size, curvature, specific surface area, and tortuosity, exert a profound influence on bone scaffold performance. By finely adjusting the above parameters, it becomes feasible to substantially optimize the structural mechanical characteristics of the scaffold, thereby effectively preempting the occurrence of stress shielding phenomena. Concurrently, the manipulation of these parameters can also optimize the scaffold's biological performance, facilitating cell adhesion, proliferation, and growth, while facilitating the ingrowth and permeation of bone tissue. Ultimately, the ideal bone fusion results will obtain.
CONCLUSION
The microstructure significantly and substantially influences the performance of TPMS bone scaffolds. By deeply exploring the characteristics of these microstructure effects on the performance of bone scaffolds, the design of bone scaffolds can be further optimized to better match specific implantation regions.
Tissue Scaffolds/chemistry*
;
Tissue Engineering/methods*
;
Bone and Bones
;
Porosity

Result Analysis
Print
Save
E-mail