1.Coronary Computed Tomographic Angiography-Derived Radiomics Combing CT-Fractional Flow Reserve for Detecting Hemodynamically Significant Coronary Artery Disease.
Yan YI ; Cheng XU ; Wei WU ; Ying-Qian GE ; Ke-Ting XU ; Xian-Bo YU ; Yi-Ning WANG
Acta Academiae Medicinae Sinicae 2025;47(4):542-549
Objective To develop a diagnostic model combining the CT angiography(CCTA)-derived myocardial radiomics signatures with the CT-derived fractional flow reserve(CT-FFR)based on coronary CCTA and investigate the diagnostic accuracy of the hybrid model for hemodynamically significant coronary artery disease(CAD).Methods The patients presenting stable angina pectoris,diagnosed with CAD,and clinically referred for CCTA examination and invasive coronary angiography were prospectively recruited.Radiomics features of the left ventricular myocardium were extracted from the three main perfusion territories demarcated according to the coronary blood supply.The extracted features were first selected by the minimum redundancy maximum relevance feature ranking method.A least absolute shrinkage and selection operator Logistic regression algorithm with leave-one-out cross-validation was then employed to construct a radiomics model.The CT-FFR value was generated for each blood vessel.The area under the receiver operating characteristics curve(AUC_ROC),sensitivity,and specificity were adopted to evaluate the performance of each model against the reference standard invasive coronary angiography/FFR.Results A total of 70 patients[42 men and 28 women;(61±10) years old] were included in this study and complemented CCTA examination,with 175 vessels and the corresponding myocardial territories undergoing invasive coronary angiography/FFR.A total of 1 656 specific radiomics parameters were extracted,from which 14 features were selected to establish the radiomics model.The AUC_ROC,sensitivity,and specificity were 0.797(95%CI=0.732-0.861),77.1%,and 73.7%for the radiomics model,0.892(95%CI=0.841-0.943),81.4%,and 88.8%for the CT-FFR model,and 0.928(95%CI=0.890-0.965),83.3%,and 88.4%for the hybrid model,respectively.The hybrid model outperformed the radiomics model and CT-FFR alone(P=0.040).Conclusions The radiomics signatures of the vessel-related myocardium from CCTA could provide incremental value to the diagnostic performance of CT-FFR and improve vessel-specific ischemia detection.The hybrid model combining CT-FFR with radiomics signatures is potentially feasible for improving the diagnostic accuracy for hemodynamically significant CAD.
Coronary Angiography/methods*
;
Tomography, X-Ray Computed
;
Humans
;
Hemodynamics
;
Coronary Artery Disease/diagnostic imaging*
;
Male
;
Female
;
Middle Aged
;
Aged
;
Radiomics
;
Angina Pectoris/diagnostic imaging*
;
China
;
Image Processing, Computer-Assisted
;
Coronary Vessels/diagnostic imaging*
2.A novel arterial coupler with non-return snap-fit connection approach optimized arterial end-to-end anastomotic technique: An experimental study.
Hong-Bo GUO ; Mo-Fei WANG ; Ren-Qi YIN ; Kang-Kang ZHI
Chinese Journal of Traumatology 2025;28(1):13-21
PURPOSE:
Hand-sewn anastomosis as the gold standard of vascular anastomosis cannot fully meet the requirements of vascular anastomosis in speed and quality. Various vascular couplers have been developed to ameliorate this situation. Most of them are mainly used for venous anastomosis rather than arterial anastomosis. Although it is generally acknowledged that in almost all operations involving vascular reconstruction, it is the arteries that need to be anastomosed faster and more accurately and not the veins. A dedicated device is needed for creating arterial anastomosis in an easy, timesaving, less damaging but reliable procedure. Therefore, we plan to develop a novel arterial coupler device and test pre-clinical safety and effectiveness.
METHODS:
In this cohort study, the rationality of this novel arterial coupler was preliminarily tested by finite element analysis before it was manufactured. Several factors restrict the use of vascular couplers in arterial anastomosis, such as arterial eversion, fixation, etc. The manufactured arterial couplers underwent in vitro and in vivo experiments. In vitro, isolated arteries of beagles were anastomosed with the assistance of an arterial coupler, and the anastomosed arteries were evaluated through anti-traction tests. In animal experiments, the bilateral femoral arteries of 5 beagles served as a control group. After dissection, the femoral artery on one side was randomly selected to be anastomosed with a quick arterial coupler (QAC) (QAC group), and the femoral artery on the other side was anastomosed by the same person using an end-to-end suture technique with a 6-0 Prolene suture (suture group). The bilateral femoral arteries of 5 beagles were used for coupler-assisted anastomosis and hand-sewn anastomosis in vivo, respectively. Success rate, blood loss, anastomotic time, clamp time, total operation time, and patency rate were recorded. The patency of anastomosed arteries was assessed using vascular Doppler ultrasound, electromagnetic flowmeter, and pathological examination (6 weeks after surgery).
RESULTS:
As a novel arterial coupler, QAC was successfully designed and manufactured by using poly lactic-co-glycolic acid raw materials and 3-dimensions printing technology. Its rationality was preliminarily tested through finite element analysis and related mechanical analysis methods. The isolated arteries were successfully anastomosed with the assistance of QAC in vitro testing, which showed good anti-traction properties. In animal studies, QAC-assisted arterial anastomosis has superior profiles compared to hand-sewn anastomosis in anastomotic time (7.80 ± 1.41 vs. 16.38 ± 1.04 min), clamp time (8.80 ± 1.41 vs. 14.14 ± 1.57 min), and total operation time (46.64 ± 2.38 vs. 51.96 ± 3.65 min). The results of electromagnetic flowmeter, vascular Doppler ultrasound, and pathological examination showed that QAC-assisted anastomotic arteries were superior to hand-sewn arteries in terms of postoperative blood flow (16.86 ± 3.93 vs. 10.36 ± 0.92 mL/min) and vascular patency in 6 weeks after surgery.
CONCLUSION
QAC is a well-designed and easily maneuverable device specialized for end-to-end arterial anastomosis. Application of this device may decrease thermal ischemia time and improve the patency of anastomotic arteries, thus, improving outcomes.
Animals
;
Anastomosis, Surgical/instrumentation*
;
Dogs
;
Femoral Artery/surgery*
;
Vascular Surgical Procedures/instrumentation*
;
Finite Element Analysis
3.Berberine ameliorates coronary artery endothelial cell injury in Kawasaki disease through complement and coagulation cascades.
Jin-Wen LIAO ; Xin GUO ; Bo LIANG ; Xu-Xia LI ; Ming-Guo XU
Chinese Journal of Contemporary Pediatrics 2025;27(1):101-108
OBJECTIVES:
To explore the role of berberine (BBR) in ameliorating coronary endothelial cell injury in Kawasaki disease (KD) by regulating the complement and coagulation cascade.
METHODS:
Human coronary artery endothelial cells (HCAEC) were divided into a healthy control group, a KD group, and a BBR treatment group (n=3 for each group). The healthy control group and KD group were supplemented with 15% serum from healthy children and KD patients, respectively, while the BBR treatment group received 15% serum from KD patients followed by the addition of 20 mmol/L BBR. Differential protein expression was analyzed and identified using isobaric tags for relative and absolute quantitation technology and liquid chromatography-tandem mass spectrometry, followed by GO functional enrichment analysis and KEGG signaling pathway enrichment analysis of the differential proteins. Western blot was used to detect differential protein expression.
RESULTS:
A total of 518 differential proteins were identified between the KD group and the healthy control group (300 upregulated proteins and 218 downregulated proteins). A total of 422 differential proteins were identified between the BBR treatment group and the KD group (221 upregulated proteins and 201 downregulated proteins). Bioinformatics analysis showed that compared to the healthy control group, the differential proteins in the KD group were enriched in the complement and coagulation cascade and ribosome biogenesis in eukaryotes. Compared to the KD group, the differential proteins in the BBR treatment group were also enriched in the complement and coagulation cascade and ribosome biogenesis in eukaryotes. Western blot results indicated that compared to the healthy control group, the expression of complement C1q subcomponent subunit C (C1QC), kininogen-1 (KNG1), complement C1s subcomponent (C1S), and C4b-binding protein alpha chain (C4BPA) was increased in the KD group (P<0.05). Compared to the KD group, the expression of KNG1, C1S, C1QC, and C4BPA was decreased in the BBR treatment group (P<0.05).
CONCLUSIONS
The complement and coagulation cascade may be involved in the regulation of BBR treatment for coronary injury in KD, and C1QC, KNG1, C1S, and C4BPA may serve as biomarkers for this treatment.
Mucocutaneous Lymph Node Syndrome/blood*
;
Humans
;
Endothelial Cells/pathology*
;
Complement System Proteins/physiology*
;
Coronary Vessels/drug effects*
;
Male
;
Blood Coagulation/drug effects*
;
Berberine/therapeutic use*
;
Female
;
Child, Preschool
;
Infant
4.Diagnosis of coronary artery lesions in children based on Z-score regression model.
Yong WANG ; Jia-Ying JIANG ; Yan DENG ; Bo LI ; Ping SHUAI ; Xiao-Ping HU ; Yin-Yan ZHANG ; Han WU ; Lu-Wei YE ; Qian PENG
Chinese Journal of Contemporary Pediatrics 2025;27(2):176-183
OBJECTIVES:
To construct a Z-score regression model for coronary artery diameter based on echocardiographic data from children in Sichuan Province and to establish a Z-score calculation formula.
METHODS:
A total of 744 healthy children who underwent physical examinations at Sichuan Provincial People's Hospital from January 2020 to December 2022 were selected as the modeling group, while 251 children diagnosed with Kawasaki disease at the same hospital from January 2018 to December 2022 were selected as the validation group. Pearson correlation analysis was conducted to analyze the relationships between coronary artery diameter values and age, height, weight, and body surface area. A regression model was constructed using function transformation to identify the optimal regression model and establish the Z-score calculation formula, which was then validated.
RESULTS:
The Pearson correlation analysis showed that the correlation coefficients for the diameters of the left main coronary artery, left anterior descending artery, left circumflex artery, and right coronary artery with body surface area were 0.815, 0.793, 0.704, and 0.802, respectively (P<0.05). Among the constructed regression models, the power function regression model demonstrated the best performance and was therefore chosen as the optimal model for establishing the Z-score calculation formula. Based on this Z-score calculation formula, the detection rate of coronary artery lesions was found to be 21.5% (54/251), which was higher than the detection rate based on absolute values of coronary artery diameter. Notably, in the left anterior descending and left circumflex arteries, the detection rate of coronary artery lesions using this Z-score calculation formula was higher than that of previous classic Z-score calculation formulas.
CONCLUSIONS
The Z-score calculation formula established based on the power function regression model has a higher detection rate for coronary artery lesions, providing a strong reference for clinicians, particularly in assessing coronary artery lesions in children with Kawasaki disease.
Humans
;
Male
;
Female
;
Child, Preschool
;
Child
;
Coronary Artery Disease/diagnostic imaging*
;
Infant
;
Mucocutaneous Lymph Node Syndrome
;
Regression Analysis
;
Coronary Vessels/diagnostic imaging*
;
Echocardiography
;
Adolescent
5.Efficacy of volume-guaranteed high-frequency oscillatory ventilation in preterm infants with respiratory distress syndrome and its impact on cerebral blood flow in the middle cerebral artery.
Yue-Yi WANG ; Xue-Xu WEI ; Hai-Wei YIN ; Hong-Bin ZHU
Chinese Journal of Contemporary Pediatrics 2025;27(3):286-292
OBJECTIVES:
To investigate the efficacy of volume-guaranteed high-frequency oscillatory ventilation (HFOV-VG) in preterm infants with respiratory distress syndrome (RDS) and its impact on blood flow in the middle cerebral artery (MCA).
METHODS:
A prospective study was conducted on 120 preterm infants with RDS who were admitted to the Department of Neonatology at Qinhuangdao Maternal and Child Health Hospital from March 2020 to December 2023. According to the mode of ventilation, the infants were divided into two groups: a conventional mechanical ventilation (CMV) group (60 infants) and an HFOV-VG group (60 infants). The two groups were compared in terms of baseline data, MCA hemodynamic parameters, complications, and outcomes.
RESULTS:
Compared with the CMV group, the HFOV-VG group had significantly shorter durations of mechanical ventilation and hospital stay and a significantly higher overall response rate (P<0.05). The HFOV-VG group demonstrated significantly better peak systolic velocity, end-diastolic velocity, and mean flow velocity (P<0.05). The HFOV-VG group also exhibited significantly lower 28-day mortality rates and lower incidence rates of bronchopulmonary dysplasia and intraventricular hemorrhage than the CMV group (P<0.05).
CONCLUSIONS
HFOV-VG can effectively improve cerebral blood perfusion, reduce cerebrovascular resistance, shorten the durations of mechanical ventilation and hospital stay, and enhance overall treatment efficacy. It has significant advantages in reducing the risk of 28-day mortality, bronchopulmonary dysplasia, and intraventricular hemorrhage in preterm infants with RDS.
Humans
;
High-Frequency Ventilation/adverse effects*
;
Infant, Newborn
;
Respiratory Distress Syndrome, Newborn/physiopathology*
;
Female
;
Middle Cerebral Artery/physiology*
;
Male
;
Prospective Studies
;
Cerebrovascular Circulation
;
Infant, Premature
6.Efficacy and safety of concomitant left atrial appendage clipping during heart valve surgery: a report of 58 cases.
Zheng XU ; Haiyan XIANG ; Jiwei WANG ; Chen LIU ; Yanhua TANG ; Juesheng YANG
Journal of Zhejiang University. Medical sciences 2025;54(2):250-256
OBJECTIVES:
To analyze the efficacy and safety of concomitant left atrial appendage clipping during heart valve surgery for valvular heart disease patients with atrial fibrillation.
METHODS:
Fifty-eight patients who underwent concomitant left atrial appendage clipping during cardiac valve surgery in the Second Affiliated Hospital of Nanchang University from January 2017 to June 2023 were included in the analysis, including 1 case who underwent aortic valve replacement, 49 cases who underwent mitral valve replace-ment (or valvuloplasty)+tricuspid valvuloplasty, and 8 cases who underwent double valve replacement+tricuspid valvuloplasty (3 cases combined with coronary artery bypass grafting). The patients were followed up for 3-36 months [(16.69±6.61) months] after operation, and the changes of cardiac function and the occurrence of serious adverse complications were evaluated.
RESULTS:
The cardiopulmonary bypass time ranged from 75 to 145 min [(102.50±21.03) min], and the aortic cross-clamp time ranged from 35 to 80 min [(58.02±14.63) min]. The length of postoperative intensive care unit stay was 1 to 5 days [(2.47±0.82) d], and the length of postoperative hospital stay was 7 to 22 days [(10.84±2.69) d]. Cardiac ultrasound indicated complete closure of the left atrial appendage in all cases. During the follow-up, New York Heart Association (NYHA) functional classifications were improved in 54 patients. No left atrial appendage-related bleeding events or other perioperative complications were observed; and no cerebral infarction, limb embolism events, or mortality cases occurred during the follow-up.
CONCLUSIONS
For valvular heart disease patients with atrial fibrillation, concomitant left atrial appendage clipping during cardiac valve surgery demonstrates efficacy and safety, with no severe adverse events during a medium-term follow-up.
Humans
;
Atrial Appendage/surgery*
;
Atrial Fibrillation/complications*
;
Male
;
Female
;
Heart Valve Diseases/complications*
;
Aged
;
Middle Aged
;
Heart Valve Prosthesis Implantation/methods*
;
Treatment Outcome
;
Cardiac Surgical Procedures/methods*
;
Mitral Valve/surgery*
7.A case of coronary artery protection in transcatheter aortic valve replacement of quadricuspid aortic valve.
Zhipeng CHEN ; Dong YANG ; Han ZHANG
Journal of Zhejiang University. Medical sciences 2025;54(2):161-166
A 72-year-old patient with quadricuspid aortic valve underwent transcatheter aortic valve replacement due to severe valve stenosis accompanied by moderate insufficiency. As initially planned, the right coronary artery was protected during the procedure. However, after the artificial valve was released, the left coronary artery was found to be blocked, so a coronary protection stent was implanted in the left coronary artery ostium under the guidance of intravascular ultrasonography. This case indicates that for patients with a quadricuspid aortic valve undergoing transcatheter aortic valve replacement, in addition to preoperative measurement of the aortic root, attention should also be paid to the coronary artery obstruction caused by the displacement of the artificial valve frame during the procedure.
Aged
;
Humans
;
Aortic Valve/surgery*
;
Aortic Valve Stenosis/surgery*
;
Coronary Vessels
;
Stents
;
Transcatheter Aortic Valve Replacement/methods*
8.The first intraoperative EEG monitoring during a common carotid artery endoaneurysmorrhaphy in a Philippine Tertiary Government Hospital: A case report
Athena Kate D. Antonio ; Maxine Lourraine T. Ty ; Katerina Tanya Perez-gosiengfiao
Acta Medica Philippina 2025;59(13):95-100
The surgical treatment of the rare extracranial carotid artery aneurysm can lead to significant thromboembolic events in 4.4% of cases. Intraoperative monitoring has helped detect hypoperfusion and probable ischemic events, but this is not widely available in resource-limited hospitals in the Philippines. This case highlights the use of a portable standard 21-channel EEG machine for intraoperative monitoring in a tertiary government hospital. In addition, it highlights a conception of a protocol for the intraoperative electroencephalogram monitoring of carotid endoaneurysmorrhaphy procedures in a resource-limited setting. During the aneurysmorrhaphy procedure, the authors collaborated with the surgeons and the anesthesiologists to provide feedback about EEG changes during the operation. After a pre-induction baseline was recorded, continuous EEG monitoring was performed until the patient emerged from anesthesia. Mild EEG changes, attributed to relative hypotension, were observed during the procedure. These episodes were responsive to BP augmentation. There were no EEG changes observed during carotid cross-clamping. Shunting was not recommended to the surgical team. No new neurologic deficits were documented postoperatively and on follow-up after six months. This paper illustrates how an intraoperative team was formed, and intraoperative EEG was utilized for a complex carotid endoaneurysmorrhaphy for a patient with ECAA in a tertiary government hospital in the Philippines.
Human ; Resource-limited Settings ; Carotid Arteries ; Philippines
9.Research progress of the interaction between RAAS and clock genes in cardiovascular diseases.
Rui-Ling MA ; Yi-Yuan WANG ; Yu-Shun KOU ; Lu-Fan SHEN ; Hong WANG ; Ling-Na ZHANG ; Jiao TIAN ; Lin YI
Acta Physiologica Sinica 2025;77(4):669-677
The renin-angiotensin-aldosterone system (RAAS) is crucial for regulating blood pressure and maintaining fluid balance, while clock genes are essential for sustaining biological rhythms and regulating metabolism. There exists a complex interplay between RAAS and clock genes that may significantly contribute to the development of various cardiovascular and metabolic diseases. Although current literature has identified correlations between these two systems, the specific mechanisms of their interaction remain unclear. Moreover, the interaction patterns under different physiological and pathological conditions need further investigation. This review summarizes the synergistic roles of the RAAS and clock genes in cardiovascular diseases, explores their molecular mechanisms and pathophysiological connections, discusses the application of chronotherapy, and highlights potential future research directions, aiming to provide novel insights for the prevention and treatment of related diseases.
Humans
;
Renin-Angiotensin System/genetics*
;
Cardiovascular Diseases/genetics*
;
CLOCK Proteins/physiology*
;
Animals
10.Research progress on cardiovascular protective mechanism of resveratrol.
Qian WU ; Hui-Min LI ; Chun-Kun YANG ; Ying-Tian YANG ; Shi-Han WANG
China Journal of Chinese Materia Medica 2025;50(12):3244-3251
Resveratrol(Res) is a kind of polyphenolic compound, possessing multiple biological activities such as antioxidant, anti-inflammatory, cardioprotective, and anticancer effects. In recent years, the cardiovascular protective mechanism of Res has become a research hotspot. Studies have shown that Res has a protective effect on the cardiovascular system through various pathways, such as inhibiting oxidative stress, regulating ferroptosis of cells, improving ischemia-reperfusion(I/R) injury, regulating lipid metabolism, suppressing inflammatory responses, and enhancing endothelial function. It can also alleviate cardiotoxicity caused by drugs and chemicals. In terms of oxidative stress, Res reduces the level of intracellular reactive oxygen species(ROS) by enhancing the expression of proteins such as silent information regulator 1(SIRT1) and regulating mitochondrial function, thereby alleviating myocardial cell damage. Regarding ferroptosis, Res inhibits the occurrence of ferroptosis by regulating the expression of proteins related to iron metabolism. Res can also improve I/R injury through mechanisms such as activating autophagy and the mitochondrial quality control network. In regard to improving endothelial function, Res protects the function of endothelial cells by regulating multiple signaling pathways, such as downregulating the PREP1-mediated pathway. Res can also regulate lipid metabolism and inhibit the progression of atherosclerosis. In terms of inflammatory responses, Res exerts anti-inflammatory effects through mechanisms such as inhibiting the nuclear factor-kappa B(NF-κB) signaling pathway. In addition, Res has an improving effect on cardiotoxicity caused by different drugs or environmental factors. However, the clinical application of Res still faces limitations such as poor pharmacokinetic properties. In the future, in-depth exploration is needed at multiple levels from basic research to clinical application to clarify the dose-response relationship and standardize the standards of medication regimens with the expectation of providing more effective strategies for the prevention and treatment of cardiovascular diseases.
Humans
;
Resveratrol/pharmacology*
;
Animals
;
Cardiotonic Agents/pharmacology*
;
Oxidative Stress/drug effects*
;
Cardiovascular Diseases/genetics*
;
Cardiovascular System/metabolism*
;
Signal Transduction/drug effects*


Result Analysis
Print
Save
E-mail