1.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
2.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
7.Correlation Between the Distance From Donors and Ischemic Time in Heart Transplantation of Korea and Its Clinical Impact
Jung Yeon JIN ; Chee-hoon LEE ; Mi Hee LIM ; Soo Yong LEE ; Min Ho JU ; Hyung Gon JE
Journal of Korean Medical Science 2025;40(11):e60-
Background:
The heart donor allocation system in South Korea is divided into three regions, with priority given to recipients within the same region over those in other regions of the same tier. It is commonly believed that heart transplantation (HT) within the same region can reduce ischemic time (IT), although its clinical impact remains unclear. The purpose of this study is to compare the characteristics and outcomes of intra-region HT and inter-region HT.
Methods:
From 2014 to 2022, a total of 115 adult patients underwent isolated HT at a tertiary hospital. Of these, 58 recipients (54.5 ± 10.3 years, female, 36.2%) underwent intra-region HT and 57 recipients (53.9 ± 14.1 years, female, 31.6%) underwent inter-region HT. Extracorporeal membrane oxygenation-bridged HTs accounted for 50.0% and 54.4% of cases, respectively (P = 0.638). There were no differences in preoperative characteristics between the two groups.
Results:
The median inter-hospital distance (38.0 [32.0–112.0] km vs. 351.0 [300.0–390.5] km, P < 0.001) and total IT (153 [123–170] minute vs. 265 [243–298] minute, P < 0.001) were longer in the inter-region group than intra-region group. Despite these differences, both groups showed similar clinical outcomes. The 30-day mortality rates were 5.2% and 5.3% (P < 0.99), respectively. There were no differences in postoperative cardiac index, early adverse outcomes, or long-term survival between the two groups. The inter-hospital distance and cold IT showed a strong positive correlation (time [minute] = 39.462 + 0.410 × distance [km]).
Conclusion
Despite the difference in IT, there was no difference in postoperative outcomes between the two groups. Based on these findings, the effect of donor location on the outcomes of HT in South Korea is not considered significant.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.The Clinical Outcomes of Marginal Donor Hearts: A Single Center Experience
Soo Yong LEE ; Seok Hyun KIM ; Min Ho JU ; Mi Hee LIM ; Chee-hoon LEE ; Hyung Gon JE ; Ji Hoon LIM ; Ga Yun KIM ; Ji Soo OH ; Jin Hee CHOI ; Min Ku CHON ; Sang Hyun LEE ; Ki Won HWANG ; Jeong Su KIM ; Yong Hyun PARK ; June Hong KIM ; Kook Jin CHUN
Korean Circulation Journal 2023;53(4):254-267
Background and Objectives:
Although the shortage of donor is a common problem worldwide, a significant portion of unutilized hearts are classified as marginal donor (MD) hearts. However, research on the correlation between the MD and the prognosis of heart transplantation (HTx) is lacking. This study was conducted to investigate the clinical impact of MD in HTx.
Methods:
Consecutive 73 HTxs during 2014 and 2021 in a tertiary hospital were analyzed.MD was defined as follows; a donor age >55 years, left ventricular ejection fraction <50%, cold ischemic time >240 minutes, or significant cardiac structural problems. Preoperative characteristics and postoperative hemodynamic data, primary graft dysfunction (PGD), and the survival rate were analyzed. Risk stratification by Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was performed to examine the outcomes according to the recipient state. Each group was sub-divided into 2 risk groups according to the IMPACT score (low <10 vs. high ≥10).
Results:
A total of 32 (43.8%) patients received an organ from MDs. Extracorporeal membrane oxygenation was more frequent in the non-MD group (34.4% vs. 70.7, p=0.007) There was no significant difference in PGD, 30-day mortality and long-term survival between groups. In the subgroup analysis, early outcomes did not differ between low- and high-risk groups. However, the long-term survival was better in the low-risk group (p=0.01).
Conclusions
The outcomes of MD group were not significantly different from non-MD group. Particularly, in low-risk recipient, the MD group showed excellent early and longterm outcomes. These results suggest the usability of selected MD hearts without increasing adverse events.

Result Analysis
Print
Save
E-mail