1.Advances in lactic acid bacteria as recombinant protein drug delivery carrier
Xufang WANG ; Yanting WANG ; Chunmeng YAO ; Bin LU
Journal of Pharmaceutical Practice and Service 2026;44(1):7-11
Lactic acid bacteria (LAB) are promising candidates for live bacterial drug delivery systems owing to their safety, probiotic properties, and ability to colonize the intestinal tract. At present, most research focuses on engineering LAB as carriers for the delivery of therapeutic proteins. As model organisms equipped with a versatile set of genetic tools, LAB can be readily modified to target various diseases and yield significant therapeutic effects. LAB-based carriers offer multiple advantages, including non-invasive delivery, ease of genetic manipulation, and suitability for large-scale production. Consequently, the use of LAB as recombinant protein expression vectors has attracted extensive research interest worldwide. The foundational principles, strategies for enhancing bioavailability, genetic engineering approaches, and the current research and application status of LAB-based drug delivery systems were summarized in this paper.
2.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
3.High-sensitivity Ratio-type Surface-enhanced Raman Substrate for Rapid Quantitative Determination of 6-Thioguanine in Serum
Yan-Bin LIU ; Yi-Chao HAN ; Rong WANG ; Xiao-Mei WU ; Qin WANG ; Yuan-Yuan YAO ; Yue-Liang WANG ; Long-Hua GUO
Chinese Journal of Analytical Chemistry 2025;53(8):1300-1310
6-Thioguanine(6-TG)is an antineoplastic agent used in treatment of acute leukemia.However,significant interindividual variability in dosing regimens and frequent clinical manifestations of hepatotoxicity and myelosuppression as adverse effects have affected its therapeutic efficacy.Consequently,the development of rapid analytical methods for 6-TG in clinical samples,enabling continuous therapeutic drug monitoring of plasma concentrations,holds substantial significance in optimizing dosage regimens,mitigating adverse reactions,and investigating drug metabolism mechanisms.In this study,multi-tipped gold nanostars(AuNSs)were prepared.With bis-(p-sulfonylphenyl)phenylphosphine molecule as the protecting agent and internal standard molecule,the AuNSs were assembled onto a highly sensitive surface-enhanced Raman(SERS)substrate for developing a ratio-based SERS quantitative analysis method for 6-TG in serum.The AuNSs containing multiple tips and gaps exhibited strong local surface plasmon resonance effect and SERS activity,ensuring the sensitivity of the analytical method.Furthermore,the introduction of internal standard molecules could improve the reproducibility,which guaranteed this method suitable for rapid analysis of drug molecules in complex samples.Quantitative analysis of 6-TG was achieved with linear detetion range of 1.0×10?4-1.0 mmol/L.In the spiked recovery experiments of serum,the RSD was less than 5.32%,and the recoveries were 94%-104%,which proved that this method could be used for rapid quantitative determination of 6-TG in serum.This method provided a powerful tool for studying drug pharmacokinetics,which could promote the optimization of the usage methods of anti-cancer drugs,and it was expected to further enhance the clinical efficacy and safety of 6-TG,enabling it to achieve the best therapeutic effect.
4.Simultaneous Determination of 21 Kinds of Aconitum Alkaloids in Biological Specimens and Herbal Wines Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
Ju YANG ; Guo-Jun LI ; Xian-Mou FAN ; Rui-Bin ZHAO ; Shao-Ming SU ; Xu-Xian FU ; En-Jin ZHU ; Qi-Lin HUANG ; Yao QIN ; Li-Na LI
Chinese Journal of Analytical Chemistry 2025;53(8):1391-1401,后插1-后插6,封3
A method for simultaneous determination of 21 kinds of Aconitum alkaloids(ATS)in biological specimens and infused liquor using ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)was developed.The biological samples were pretreated with methanol-acetonitrile(1∶2,V/V)for protein precipitation,while infused liquors were diluted 100-fold with acetonitrile,followed by centrifugation,and filtration by a 0.22-μm membrane.Chromatographic separation was carried out on an EC-C18 column using gradient elution with the mixture of 10 mmol/L ammonium acetate and 0.2%formic acid as mobile phase A and acetonitrile as mobile phase B.With this method,all the analytes were separated within 9.5 min.The samples were detected in positive ESI mode with dynamic multiple reaction monitoring(MRM)and quantified via external standard calibration.The results showed that the concentrations of the analytes in the range of 2-1000 ng/mL had excellent linearity(R2>0.9992)with the peak area.The developed method was successfully used for detection of 21 kinds of aconitum alkaloids,with limits of detection of 0.5-2 ng/mL,quantification limits of 2-6 ng/mL,intra/inter-day precision≤6.0%,spiked recoveries of 89.4%-100.9%,extraction recoveries of 74.2%-104.4%,and matrix effects ranging from-11.1%to 9.2%in blood/urine.The method was applied to detection of 12 samples from 4 fatal aconite poisoning cases,and all 21 kinds of ATS with total alkaloid concentrations of 0.04-4.18 μg/mL in blood and 154.96-422.83 μg/mL in medicinal liquors were detected.Tissue distribution revealed that the order of concentrations from highest to lowest is as follows:urine(157.22 μg/mL)>gastric contents(51.37 μg/mL)>kidney(21.6 μg/g)>whole blood(4.18 μg/mL)>liver(0.03 μg/g).This method showed many advantages such as simple pretreatment,low detection limits,accurate quantification,broad analyte coverage,and superior anti-interference capability in complex matrices,proving ideal for forensic and toxicological analysis of aconitum alkaloids.
5.Mechanism of Zuogui Pills in regulating bone metabolism through OXT/OXTR feed-forward loop based on theory of "all marrows dominated by brain".
Yan-Chen FENG ; Ya-Li LIU ; Xue DANG ; Lu SUN ; Jin-Yao LI ; Jia-Bin SONG ; Shun-Zhi YANG ; Fei-Xiang LIU
China Journal of Chinese Materia Medica 2025;50(10):2761-2768
Grounded in the theory of "all marrows dominated by brain", this study explored the therapeutic mechanism of Zuogui Pills in modulating the oxytocin(OXT)/oxytocin receptor(OXTR) feed-forward loop in the treatment of postmenopausal osteoporosis(PMOP). A PMOP rat model was established using ovariectomy, and 70 Sprague-Dawley female rats were randomly divided into the following groups: sham operation group, model group, estradiol group(17β-estradiol, 0.05 mg·kg~(-1)·d~(-1)), Zuogui Pills low, medium, and high dose groups(0.2, 0.4, 0.8 g·kg~(-1)·d~(-1), respectively), and an antagonist group(atosiban 0.9 mg·kg~(-1)·d~(-1) + 17β-estradiol 0.05 mg·kg~(-1)·d~(-1) + Zuogui Pills 0.4 g·kg~(-1)·d~(-1)). After 12 weeks of model establishment, treatment was administered by gavage once daily for another 12 weeks, followed by sample collection. Enzyme-linked immunosorbent assay(ELISA) was used to measure serum levels of estrogen(E_2), OXT, tartrate-resistant acid phosphatase(TRACP-5b), and bone alkaline phosphatase(BALP). Histopathological changes in the left distal femur were observed through hematoxylin and eosin(HE) staining. Micro-computed tomography(micro-CT) was used to analyze the microstructure of the right distal femur. Western blot was employed to detect the expression levels of OXTR, small GTP-binding protein Ras, Raf1 proto-oncogene(Raf1), mitogen-activated protein kinase kinase 1/2(MEK1/2), and extracellular signal-regulated kinase 1/2(ERK1/2), and their phosphorylated forms in tibial tissues. Compared with the model group, the Zuogui Pills medium and high dose groups showed significantly increased levels of E_2, OXT, and BALP, with a notable decrease in TRACP-5b levels. Morphologically, the trabeculae in the left distal femur were more tightly arranged. The fibrous structure in the right distal femur was significantly improved in the Zuogui Pills high dose group. Additionally, the expression of OXTR, Ras, p-Raf1, p-MEK1/2, and p-ERK1/2 proteins in tibial tissues was significantly increased. The therapeutic effect of the Zuogui Pills high dose group was partially inhibited when an OXTR antagonist was administered. These findings suggest that Zuogui Pills can regulate the OXT/OXTR feed-forward loop, activate the phosphorylation of the downstream Ras/Raf1/MEK/ERK signaling pathway, and ultimately improve bone mineral density, thereby exerting therapeutic effects in PMOP.
Animals
;
Rats, Sprague-Dawley
;
Rats
;
Female
;
Drugs, Chinese Herbal/administration & dosage*
;
Oxytocin/genetics*
;
Receptors, Oxytocin/genetics*
;
Humans
;
Osteoporosis, Postmenopausal/genetics*
;
Bone and Bones/drug effects*
;
Brain/drug effects*
;
Bone Marrow/drug effects*
6.3D-EDiffMG: 3D equivariant diffusion-driven molecular generation to accelerate drug discovery.
Chao XU ; Runduo LIU ; Yufen YAO ; Wanyi HUANG ; Zhe LI ; Hai-Bin LUO
Journal of Pharmaceutical Analysis 2025;15(6):101257-101257
Structural optimization of lead compounds is a crucial step in drug discovery. One optimization strategy is to modify the molecular structure of a scaffold to improve both its biological activities and absorption, distribution, metabolism, excretion, and toxicity (ADMET) properties. One of the deep molecular generative model approaches preserves the scaffold while generating drug-like molecules, thereby accelerating the molecular optimization process. Deep molecular diffusion generative models simulate a gradual process that creates novel, chemically feasible molecules from noise. However, the existing models lack direct interatomic constraint features and struggle with capturing long-range dependencies in macromolecules, leading to challenges in modifying the scaffold-based molecular structures, and creates limitations in the stability and diversity of the generated molecules. To address these challenges, we propose a deep molecular diffusion generative model, the three-dimensional (3D) equivariant diffusion-driven molecular generation (3D-EDiffMG) model. The dual strong and weak atomic interaction force-based long-range dependency capturing equivariant encoder (dual-SWLEE) is introduced to encode both the bonding and non-bonding information based on strong and weak atomic interactions. Additionally, a gate multilayer perceptron (gMLP) block with tiny attention is incorporated to explicitly model complex long-sequence feature interactions and long-range dependencies. The experimental results show that 3D-EDiffMG effectively generates unique, novel, stable, and diverse drug-like molecules, highlighting its potential for lead optimization and accelerating drug discovery.
7.Design and application of an adjustable facial support pad for prone position ventilation.
Zhimin ZHANG ; Xiaojie CHEN ; Xinyu YAO ; Bin LI ; Yafang WANG ; Lin ZHANG
Chinese Critical Care Medicine 2025;37(1):70-72
In recent years, prone mechanical ventilation has been widely used to improve oxygenation dysfunction in critically ill patients. During prone mechanical ventilation, the patient's face is compressed for a long time, and due to the difficulty in changing, facial pressure injuries and ocular complications are common and severe. These complications increase patient discomfort, reduce their tolerance and compliance with prone ventilation, and even cause tracheal tube displacement or dislodgement, leading to significant clinical challenges. In order to change this situation, the medical staff of the department of critical care medicine of the Second People's Hospital of Hengshui and the department of critical care medicine of Harrison International Peace Hospital had developed an adjustable facial support pad for prone ventilation, and obtained a National Utility Model Patent of China (ZL 2022 2 3295294.4). The device is composed of a facial support platform, a supporting telescopic foot frame and so on. There are front, back, left and right adjustable tracks below the support cushion platform, which can be adjusted to the best state suitable for the patient's face shape, which can alleviate the facial pressure injuries and ocular complications caused by the different sizes of each patient's face, improve the patient's comfort, and reduce the incidence of facial pressure injury and the occurrence of ocular complications of the patient. The height of the platform is adjusted by the telescopic feet, and there is a hook assembly below, which can be fixed by the clamp of the ventilator tubing, so as to prevent the ventilator tubing from pulling the endotracheal intubation due to the gravity of condensation, resulting in the displacement or even prolapse of the tracheal intubation, and reducing the occurrence of adverse events of tracheal intubation. It is worth promoting in the clinic.
Humans
;
Respiration, Artificial/methods*
;
Prone Position
;
Equipment Design
;
Face
8.Association between adiponectin copy number variation region and gestational diabetes mellitus
Ziheng LI ; Haiyan LIU ; Yao DONG ; Kailin WANG ; Jin LIU ; Huilu CUI ; Qing LI ; Anqun HU ; Zongguang LI ; Bin WANG ; Yingjie ZHENG
Chinese Journal of Epidemiology 2025;46(5):867-873
Objective:To investigate the association between adiponectin-related copy number variation (CNV) region (CNVR) and gestational diabetes mellitus (GDM).Methods:Pregnant women who had prenatal screening in Anqing Municipal Hospital, Anhui Province, from February 2018 to December 2020 were surveyed for baseline information collection, and blood samples were collected. The outcome information was obtained by post pregnancy follow-up. Latex-enhanced immunoturbidimetry and ASA-CHIA chip were used to detect serum adiponectin levels and CNV of pregnant women, respectively. After genotyping, CNV data were processed with software PennCNV 1.0.5 following standard quality control procedure. CNVR were identified and integrated by using software R 4.3.3. Then the associations between CNVR and adiponectin was evaluated, and gene annotation and over-representation analysis were conducted. The log-binomial regression model was used to adjust relevant covariates and analyze the association between adiponectin-related CNVR and GDM.Results:The detection rate of GDM was 9.54% (176/1 845) in the pregnant women. The genotyping information of 1 840 people (99.73%) passed quality evaluation. A total of 33 878 CNVs were identified, and 1 449 CNVRs were obtained after integration. After the false discovery rate method correction, CNVR_132 (CHR2: 47611743-47635062), CNVR_254 (CHR3: 10182703-10183872), CNVR_691 (CHR7: 150637053-150834539) and CNVR_1101 (CHR14: 104248431-104830620) were correlated with adiponectin levels (all P<0.05). Over- representation analysis showed that the molecular function of ribonucleotide binding [Gene Ontology (GO): 0032553] was significantly enriched based on the GO database. The log-binomial regression model, adjusting age, pre-pregnancy BMI, history of miscarriage, smoking history, and family history of diabetes, indicated that CNVR_132 (CHR2: 47611743-47635062) and CNVR_1101 (CHR14: 104248431-104830620) were not statistically associated with the risk for GDM (both P>0.05). However, CNVR_254 (CHR3: 10182703-10183872, a RR=1.83, 95% CI: 1.15-2.91) and CNVR_691 (CHR7: 150637053-150834539, a RR=1.73, 95% CI: 1.23-2.43) might be associated with an increased risk for GDM (all P<0.05). Conclusion:Adiponectin-related CNVR_254 (CHR3: 10182703-10183872) and CNVR_691 (CHR7: 150637053-150834539) might be risk factors for the incidence of GDM.
9.The impact of different bolus application methods on chest wall skin dose after radical mastectomy for breast cancer
Zuohuai HU ; Jiandong FU ; Xiaofang LI ; Xinyue YAO ; Bin ZHAO ; Shu YAN ; Sisi HE
The Journal of Practical Medicine 2025;41(14):2138-2142
Objective To investigate the impact of different application methods of tissue compensators(bolus)on the skin dose delivered to the chest wall following radical mastectomy for breast cancer.Methods A retrospective analysis was conducted on 60 female patients who underwent radical mastectomy and required chest wall radiotherapy at the hospital between January 2023 and March 2025.The Pinnacle3 9.10 radiotherapy planning system(TPS)was utilized to design two VMAT dual semi-arc radiotherapy plans for each patient,with a prescribed target dose of 50 Gy delivered in 2 Gy fractions over 25 sessions.In Plan 1,a Bolus was applied and optimized during the first 15 fractions,and subsequently removed for the remaining 10 fractions without re-optimization.The sub-field configuration and dose weighting from the initial optimization were retained,and only dose recalculations were performed.The final treatment plan combined both the Bolus-included and Bolus-excluded phases.In contrast,Plan 2 involved the application and optimization of Bolus during the first 15 fractions,followed by its removal and re-optimization of the plan for the last 10 fractions.The two optimized plans were then combined for the overall treatment delivery.Data from the two plan groups were analyzed using a paired sample t-test with SPSS 29.0 software.Results There was a statistically significant difference(P<0.05)in skin Dmean,V52.5,and V55;heart Dmean,V5,V30,and V40;affected lung Dmean,V5,and V20;PRVcord Dmean and Dmax;healthy breast Dmean,V5,and V10;affected humeral head Dmean and V30;as well as PTV Dmean,V50,V55,D2%,D98%,CI,and MU.Moreover,the dose distribution on the target layer and the DVH curves showed marked differences.However,no statistically significant difference was observed in PTV HI(P=0.125).Conclusion The combination of the two optimized plans,consisting of 15 fractions with bolus and 10 fractions without bolus,more accurately reflects the dose distri-bution within the planned target area and organs at risk,thereby providing enhanced protection for the patient's chest wall skin.
10.Research progress on treatment of pleural effusion related to immune checkpoint inhibitors
Tianqi AN ; Jianhui TIAN ; Yiyang ZHOU ; Bin LUO ; Zujun QUE ; Yao LIU ; Pan YU ; Ruihua ZHAO ; Yun YANG
China Oncology 2025;35(3):333-338
Immunotherapy for cancer,as an emerging treatment modality,has made significant strides in recent years and has become a crucial therapeutic approach following surgery,radiotherapy,chemotherapy,and targeted therapy.In particular,the clinical utilization of immune checkpoint inhibitors(ICIs)has not only enhanced the survival rates of patients with refractory or recurrent tumors but has also significantly optimized the overall strategy for cancer treatment.However,as the population undergoing cancer immunotherapy continues to grow,this expansion not only yields clinical benefits but also precipitates a range of specific adverse reactions known as immune-related adverse events(irAEs).Pleural effusion is a common and severe complication in cancer patients,significantly affecting both their quality of life and treatment outcomes.Typically,tumor-related pleural effusion is often due to pleural metastasis,with malignant pleural effusion(MPE)characterized by rapid growth,being difficult to control,and tendency for recurrence.With the approval of new drugs and the expansion of indications for existing medications,the number of cancer patients receiving ICIs treatment is increasing,bringing ICIs-related pleural effusion into focus.While ICIs treatment-related pleural effusion is relatively rare in clinical practice,it is closely linked to treatment choices of patients and prognosis.Unlike MPE,the pathogenesis of ICIs treatment-related pleural effusion is more complex,not only involving non-specific immune activation leading to autoimmune inflammatory reactions but also potentially related to nodular pleural granulomatous reactions,eosinophilic chronic pleurisy,and tumor-infiltrating lymphocytes.In terms of diagnosis,ICIs treatment-related pleural effusion is typically diagnosed through exclusion,requiring the exclusion of other causes such as tumor progression,radiotherapy,and chemotherapy-induced pleural effusion,adding complexity and difficulty to the diagnostic process.Treatment for ICIs treatment-related pleural effusion often involves glucocorticoids,tocilizumab,or infliximab,aiming to alleviate symptoms and improve prognosis by suppressing excessive immune reactions.Preventing the occurrence of ICIs treatment-related pleural effusion is equally crucial,necessitating comprehensive patient assessment before ICIs administration and continuous monitoring during treatment to promptly detect and manage potential adverse reactions.Through this comprehensive management approach,the impact of ICIs treatment-related pleural effusion on patient quality of life and treatment outcomes can be minimized,optimizing overall treatment results.This review aimed to explore the pathogenesis,histological features,clinical manifestations,diagnostic methods and treatment strategies of ICIs treatment-related pleural effusion,and delve into the characteristics of ICIs treatment-related pleural effusion,in order to enhance understanding of this complication and provide a reference for clinical practice.

Result Analysis
Print
Save
E-mail