1.Efficacy and Safety of Yangxue Qingnao Pills Combined with Amlodipine in Treatment of Hypertensive Patients with Blood Deficiency and Gan-Yang Hyperactivity: A Multicenter, Randomized Controlled Trial.
Fan WANG ; Hai-Qing GAO ; Zhe LYU ; Xiao-Ming WANG ; Hui HAN ; Yong-Xia WANG ; Feng LU ; Bo DONG ; Jun PU ; Feng LIU ; Xiu-Guang ZU ; Hong-Bin LIU ; Li YANG ; Shao-Ying ZHANG ; Yong-Mei YAN ; Xiao-Li WANG ; Jin-Han CHEN ; Min LIU ; Yun-Mei YANG ; Xiao-Ying LI
Chinese journal of integrative medicine 2025;31(3):195-205
OBJECTIVE:
To evaluate the clinical efficacy and safety of Yangxue Qingnao Pills (YXQNP) combined with amlodipine in treating patients with grade 1 hypertension.
METHODS:
This is a multicenter, randomized, double-blind, and placebo-controlled study. Adult patients with grade 1 hypertension of blood deficiency and Gan (Liver)-yang hyperactivity syndrome were randomly divided into the treatment or the control groups at a 1:1 ratio. The treatment group received YXQNP and amlodipine besylate, while the control group received YXQNP's placebo and amlodipine besylate. The treatment duration lasted for 180 days. Outcomes assessed included changes in blood pressure, Chinese medicine (CM) syndrome scores, symptoms and target organ functions before and after treatment in both groups. Additionally, adverse events, such as nausea, vomiting, rash, itching, and diarrhea, were recorded in both groups.
RESULTS:
A total of 662 subjects were enrolled, of whom 608 (91.8%) completed the trial (306 in the treatment and 302 in the control groups). After 180 days of treatment, the standard deviations and coefficients of variation of systolic and diastolic blood pressure levels were lower in the treatment group compared with the control group. The improvement rates of dizziness, headache, insomnia, and waist soreness were significantly higher in the treatment group compared with the control group (P<0.05). After 30 days of treatment, the overall therapeutic effects on CM clinical syndromes were significantly increased in the treatment group as compared with the control group (P<0.05). After 180 days of treatment, brachial-ankle pulse wave velocity, ankle brachial index and albumin-to-creatinine ratio were improved in both groups, with no statistically significant differences (P>0.05). No serious treatment-related adverse events occurred during the study period.
CONCLUSIONS
Combination therapy of YXQNP with amlodipine significantly improved symptoms such as dizziness and headache, reduced blood pressure variability, and showed a trend toward lowering urinary microalbumin in hypertensive patients. These findings suggest that this regimen has good clinical efficacy and safety. (Registration No. ChiCTR1900022470).
Humans
;
Amlodipine/adverse effects*
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Hypertension/complications*
;
Middle Aged
;
Treatment Outcome
;
Drug Therapy, Combination
;
Adult
;
Blood Pressure/drug effects*
;
Double-Blind Method
;
Aged
;
Antihypertensive Agents/adverse effects*
2.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional
3.Determination of Alkylamines and Alkylamides in Food Packaging Plastics by Liquid Chromatography High-Resolution Mass Spectrometry
Ling LIU ; Yi-Zhe ZHU ; Rui-Fen ZHENG ; Jun-Xian HE ; Cai-Ming TANG
Chinese Journal of Analytical Chemistry 2025;53(7):1186-1195,中插26-中插38
An efficient analytical method was developed for simultaneous detection of alkylamines and alkylamides in food packaging plastics using liquid chromatography-high resolution mass spectrometry(LC-HRMS).Based on the physicochemical properties of alkylamines and alkylamides,as well as the complexity of plastic samples,sample pretreatment and chromatographic-mass spectrometric parameters were optimized.The samples were extracted by vortex-ultrasonic extraction with a methanol-acetonitrile mixture for 15 min,followed by nitrogen evaporation to concentrate the extract,reconstitution,and analysis.The chromatographic mobile phase consisted of 0.1%formic acid aqueous solution and acetonitrile,and a gradient elution was used.The electrospray ionization(ESI)source was operated in positive ion mode,and mass spectrometry data were collected in full scan and data-dependent acquisition modes.Quantification was performed using an isotope-labeled internal standard method.The results showed that within the quantification range of 1-1000 ng/mL,the calibration curves exhibited good linearity(R2>0.99).Some compounds interfered with the validation experiments at higher concentrations,so only 10 kinds of target analytes were validated.Using a mixed food packaging plastic matrix,the recoveries at spiking levels of 40,400,and 4000 ng/g were mostly between 66.0%and 117.1%,with relative standard deviations ranging from 0.6%to 10.6%.The method was applied to detect 14 food packaging plastic samples,and the results showed that the concentrations of alkylamines and alkylamides ranged from not detected to 8924 ng/g.This method offered high sensitivity and accuracy,and was suitable for the screening and quantitative determination of alkylamines and alkylamides in plastics.
4.Analysis of the association between patent foramen ovale and migraine:advances in biomarker and imaging research
Kai-yuan LIU ; Ji-zhe XU ; Ming BAI ; Qiang WANG ; Li-he YAO
Chinese Journal of Interventional Cardiology 2025;33(9):516-522
Patent foramen ovale(PFO)demonstrates significant comorbidity with migraine,but its causal relationship and the efficacy of transcatheter closure remain controversial.This systematic review examines potential biomarkers and relevant imaging assessments for PFO-associated migraine,aiming to provide a theoretical foundation for clinical diagnosis and treatment.Key biomarkers include platelet activation markers,calcitonin gene-related peptide,homocysteine,and platelet-to-lymphocyte ratio.Imaging evaluations encompass right-to-left shunt grading(transthoracic echocardiography,transcranial Doppler ultrasound),cerebrovascular breath-holding index,characteristics of white matter hyperintensities,alterations in resting-state functional magnetic resonance imaging(rs-f-MRI)brain networks,in-situ thrombi detected by optical coherence tomography,and electroencephalogram(EEG)power spectral features.Research indicates that integrating biomarkers with imaging technologies enhances diagnostic discrimination and treatment outcome prediction.Current challenges include unclear causal relationships and insufficient standardization of detection methods.Future efforts require multidisciplinary collaboration to establish personalized diagnostic and therapeutic frameworks through multimodal indicators,thereby advancing precise prevention and treatment strategies for PFO-related migraine.
5.Deep learning-based segmentation method of neck skeletal muscle in radiotherapy patients with head and neck tumors
Zhi MING ; Ke LIU ; Bin ZENG ; Zhe WU ; Mu-jun LIU
Chinese Medical Equipment Journal 2025;46(8):11-17
Objective To propose a lightweight deep learning network-based segmentation method for automatic segmenta-tion of the skeletal muscle at the third cervical spine(C3)level.Methods Firstly,121 patients with head and neck tumors admitted to the Department of Oncology of Zigong First People's Hospital from January 2019 to December 2022 were selected and randomly divided into a training set,a validation set and a test set in the ratio of 7∶1∶2.Secondly,a lightweight Mamba architecture was introduced into the UNet network and an attention gate(AG)mechanism was added to the skip connection path to construct a MB-UNet network model.Finally,the trained network models were evaluated for segmentation performance on the test set,the MB-UNet network model was compared with manual segmentation over the results of determination of skeletal muscle area(SMA),and with classical network models in terms of parameter scale and computation effort including UNet,Deeplab V3+,U2Net,VMUNet and UltraLight-VMUNet models.The time required by the MB-UNet network model for predicting SMA and that by the physician with the assistance of the model was summarized.Results When used for segmenting the skeletal muscle at C3 level the constructued MB-UNet network model gained advantages over the classical models,with a Dice similarity coefficient of 88.23%,an intersection over union(IoU)ratio of 78.94%,a sensitivity of 91.27%and a 95%Hausdorff distance of 7.13 mm;the SMA determined by manual segementation was basically close to that by the MB-UNet network model;the MB-UNet network model behaved generally better than the classical network models,with the computation effort being 1.88 GFLOPS and the parameter scale being 0.77M;it took the MB-UNet network model 1.93 s for the prediction on the test set,and only 2 min for the physician to obtain satisfactory results with the assistance of the MB-UNet network model,which was significantly shorter than that by munual segmentation(20 min).Conclusion The proposed method contributes to segmenting the skeletal muscle at C3 level precisely and rapidly and calculating SMA accurately,which helps clinicians to quickly diagnose sarcopenia in patients with head and neck tumors and improves the diagnostic efficiency.[Chinese Medical Equipment Journal,2025,46(8):11-17]
6.Effects of Different Fixation Methods on Stability for Distal Tibial Epiphyseal Injuries in Children
Xiaoming WANG ; Zhe TUO ; Xing TONG ; Ming YANG ; Hailiang MENG ; Chenxin LIU ; Bing WANG
Journal of Medical Biomechanics 2025;40(3):713-718,748
Objective To investigate the the effects of fracture fragment size and fixation method on biomechanical stability of distal tibial epiphyseal injuries in children.Methods A three-dimensional(3D)finite element model of a Salter-Harris Ⅱ(SH-Ⅱ)epiphyseal injury with fracture fragments of varying sizes(Small,Middle,Big)was constructed using computed tomography(CT)data from the lower limb of a 10-year-old volunteer.and bone-internal fixation assemblies were created with 1-3 screws(1 S group,2 S group,3 S group)and Kirschner wire(K group).The model was subjected to gravitational forces,posterior drawer forces,and external rotation.Displacement and stress distributions on fracture fragments and fixation devices were analyzed.Results The maximum displacement for the four groups of models was concentrated at the distal end of the fracture fragment.Under gravity conditions,the maximum displacement of the distal end of the fracture fragment in the 1 S,2 S,3 S and K models in Small group was 5.69,5.57,5.56,0.11 mm,respectively,and the bone stress was 16.95,12.26,8.57 and 5.00 MPa,respectively.A high stress area at the epiphyseal plate and the fracture line was easily formed under screw fixation,while a high stress area at the edge of the epiphyseal plate was formed under Kirschner wire fixation.Conclusions When distal tibial epiphyseal injuries in children are treated by using screws,increasing the number of screws can improve the fixation stability and share local bone stress,but the connection area between the fracture fragment and the epiphyseal plate cannot be too small.Kirschner wire fixation can provide better biomechanical effects than screw fixation.
7.Bone Age Estimation of Chinese Han Adolescents's and Children's Elbow Joint X-rays Based on Multiple Deep Convolutional Neural Network Models
Dan-Yang LI ; Hui-Ming ZHOU ; Lei WAN ; Tai-Ang LIU ; Yuan-Zhe LI ; Mao-Wen WANG ; Ya-Hui WANG
Journal of Forensic Medicine 2025;41(1):48-58
Objective To explore a deep learning-based automatic bone age estimation model for elbow joint X-ray images of Chinese Han adolescents and children and evaluate its performance.Methods A total of 943(517 males and 426 females)elbow joint frontal view X-ray images of Chinese Han ado-lescents and children aged 6.00 to<16.00 years were collected from East,South,Central and North-west China.Three experimental schemes were adopted for bone age estimation.Scheme 1:Directly in-put preprocessed images into the regression model;Scheme 2:Train a segmentation network using"key elbow joint bone annotations"as labels,then input segmented images into the regression model;Scheme 3:Train a segmentation network using"full elbow joint bone annotations"as labels,then in-put segmented images into the regression model.For segmentation,the optimal model was selected from U-Net,UNet++and TransUNet.For regression,VGG16,VGG19,InceptionV2,InceptionV3,ResNet34,ResNet50,ResNet101 and DenseNet121 models were selected for bone age estimation.The dataset was randomly split into 80%(754 samples)for training and validation for model fitting and hyperparameter tuning,and 20%(189 samples)as an internal test set to test the performance of the trained model.An additional 104 elbow joint X-ray images from the same demographic and age group were col-lected and used as an external test set.Model performance was evaluated by comparing the mean ab-solute error(MAE),root mean square error(RMSE),accuracies within±0.7 years(P±0.7 years)and±1.0 years(P±1.0 years)between the estimated age and the actual age,and by drawing radar charts,scat-ter plots,and heatmaps.Results When segmented with Scheme 3,the UNet++model achieved good segmentation performance with a segmentation loss of 0.000 4 and an accuracy of 93.8%at a learning rate of 0.000 1.In the internal test set,the DenseNet121 model with Scheme 3 yielded the best results with MAE,P±0.7 years and P±1.0 years being 0.83 years,70.03%,and 84.30%,respectively.In the external test set,the DenseNet121 model with Scheme 3 also performed best,with an average MAE of 0.89 years and an average RMSE of 1.00 years.Conclusion When performing automatic bone age estima-tion using elbow joint X-ray images in Chinese Han adolescents and children,it is recommended to use the UNet++model for segmentation.The DenseNet121 model with Scheme 3 achieves optimal per-formance.Using segmentation networks,especially that trained with annotation areas encompassing the full elbow joint including the distal humerus,proximal radius,and proximal ulna,can improve the ac-curacy of bone age estimation based on elbow joint X-ray images.
8.Dual-Channel Shoulder Joint X-ray Bone Age Estimation in Chinese Han Ado-lescents Based on the Fusion of Segmentation Labels and Original Images
Hui-Ming ZHOU ; Dan-Yang LI ; Lei WAN ; Tai-Ang LIU ; Yuan-Zhe LI ; Mao-Wen WANG ; Ya-Hui WANG
Journal of Forensic Medicine 2025;41(3):208-216
Objective To explore a deep learning network model suitable for bone age estimation using shoulder joint X-ray images in Chinese Han adolescents.Methods A retrospective collection of 1 286 shoulder joint X-ray images of Chinese Han adolescents aged 12.0 to<18.0 years(708 males and 578 females)was conducted.Using random sampling,approximately 80%of the samples(1 032 cases)were selected as the training and validation sets for model learning,selection and optimization,and the other 20%samples(254 cases)were used as the test set to evaluate the model's generalization ability.The original single-channel shoulder joint X-ray images and dual-channel inputs combining original images with segmentation labels(manually annotated shoulder joint regions multiplied pixel-by-pixel with original images,followed by segmentation via the U-Net++network to retain only key shoulder joint region information)were respectively input into four network models,namely VGG16,ResNet18,ResNet50 and DenseNet121 for bone age estimation.Additionally,manual bone age estimation was con-ducted on the test set data,and the results were compared with the four network models.The mean absolute error(MAE),root mean square error(RMSE),coefficient of determination(R2),and Pear-son correlation coefficient(PCC)were used as main evaluation indicators.Results In the test set,the bone age estimation results of the four models with dual-channel input of shoulder joint X-ray images outperformed those with single-channel input in all four evaluation indicators.Among them,DenseNet121 with dual-channel input achieved best results with MAE of 0.54 years,RMSE of 0.82 years,R2 of 0.76,and PCC(r)of 0.88.Manual estimation yielded an MAE of 0.82 years,ranking second only to dual-channel DenseNet121.Conclusion The DenseNet121 model with dual-channel input combined with original images and segmentation labels is superior to manual evaluation results,and can effectively estimate the bone age of Chinese Han adolescents.
9.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
10.Effects of Different Fixation Methods on Stability for Distal Tibial Epiphyseal Injuries in Children
Xiaoming WANG ; Zhe TUO ; Xing TONG ; Ming YANG ; Hailiang MENG ; Chenxin LIU ; Bing WANG
Journal of Medical Biomechanics 2025;40(3):713-718,748
Objective To investigate the the effects of fracture fragment size and fixation method on biomechanical stability of distal tibial epiphyseal injuries in children.Methods A three-dimensional(3D)finite element model of a Salter-Harris Ⅱ(SH-Ⅱ)epiphyseal injury with fracture fragments of varying sizes(Small,Middle,Big)was constructed using computed tomography(CT)data from the lower limb of a 10-year-old volunteer.and bone-internal fixation assemblies were created with 1-3 screws(1 S group,2 S group,3 S group)and Kirschner wire(K group).The model was subjected to gravitational forces,posterior drawer forces,and external rotation.Displacement and stress distributions on fracture fragments and fixation devices were analyzed.Results The maximum displacement for the four groups of models was concentrated at the distal end of the fracture fragment.Under gravity conditions,the maximum displacement of the distal end of the fracture fragment in the 1 S,2 S,3 S and K models in Small group was 5.69,5.57,5.56,0.11 mm,respectively,and the bone stress was 16.95,12.26,8.57 and 5.00 MPa,respectively.A high stress area at the epiphyseal plate and the fracture line was easily formed under screw fixation,while a high stress area at the edge of the epiphyseal plate was formed under Kirschner wire fixation.Conclusions When distal tibial epiphyseal injuries in children are treated by using screws,increasing the number of screws can improve the fixation stability and share local bone stress,but the connection area between the fracture fragment and the epiphyseal plate cannot be too small.Kirschner wire fixation can provide better biomechanical effects than screw fixation.

Result Analysis
Print
Save
E-mail