1.Safety and accuracy of robotic-assisted screw placement in the treatment of adolescent idiopathic scoliosis
Xinuo ZHANG ; Qingjun SU ; Dongyue LI ; Luming TAO ; Yong HAI
Chinese Journal of Postgraduates of Medicine 2025;48(1):17-23
Objective:To compare the safety and accuracy between robotic-assisted screw placement and free-hand screw placement in adolescent idiopathic scoliosis (AIS) surgery.Methods:The clinical data of 69 AIS patients underwent posterior spinal scoliosis orthomorphia from December 2021 to October 2023 in Beijing Chaoyang Hospital, Capital Medical University were retrospectively analyzed. Among them, 37 patients underwent robot-assisted screw placement (robot group), and 32 patients underwent fluoroscopy-assisted free-hand screw placement (free-hand group). The basic information of surgery (operation time, intraoperative blood loss, intraoperative radiation exposure time, postoperative hospital stay and postoperative complications), screw placement indexes (single screw placement time and accuracy of screw placement) and imaging indexes (main curve correction rate, kyphotic change and lumbar lordosis change) were compared between two groups. The ln curve regression analysis method was used to evaluate the learning curve of robot-assisted screw placement therapy for AIS.Results:A total of 716 screws were placed in 32 patients of free-hand group, and 766 screws in 37 patients of robot group. The operation time, intraoperative radiation exposure time, single screw placement time and accuracy of screw placement in robot group were significantly higher than those in free-hand group: (272.30 ± 67.98) min vs. (221.66 ± 67.32) min, (149.81 ± 57.21) s vs. (116.03 ± 63.10) s, (497.97 ± 51.74) s vs. (381.47 ± 46.58) s and 97.91% (750/766) vs. 91.48% (655/716), and there were statistical differences ( P<0.01 or <0.05); there were no statistical differences in intraoperative blood loss, postoperative hospital stay, incidence of neurological complications, incidence of incision infection and number of screw between two groups ( P>0.05). There were no statistical differences in the main curve correction rate, kyphotic change and lumbar lordosis change between two groups ( P>0.05). When the fitting degree was the highest ( R2 = 0.729, P<0.01), the fitting equation was y = - 50.93ln x + 634.7 ( x was the number of operation, and y was the single screw placement time), and the number of vertices was 12 cases. The robot group was divided into three subgroups according to the order of surgery, subgroup A consisted of 12 patients who underwent the surgery from first to twelfth, subgroup B consisted of 12 patients who underwent the surgery from thirteenth to twenty-fourth, and subgroup C consisted of 13 patients who underwent the surgery from twenty-fifth to thirty-seventh. Among them, the single screw placement time in subgroup A was significantly longer than that in subgroup B and subgroup C: (560.92 ± 35.03) s vs. (465.75 ± 21.20) and (469.62 ± 24.94) s, and there was statistical difference ( P<0.05); there was no statistical difference between subgroup B and subgroup C ( P>0.05). Conclusions:Robot-assisted screw placement for AIS can effectively improve the accuracy of screw placement without affecting deformity correction, but it can increase screw placement time, operation time and radiation exposure time. A smooth learning curve is obtained after performing 12 procedures.
2.Prognostic value of neutrophil-to-lymphocyte ratio combined with CURB-65 score for elderly patients with community-acquired pneumonia admitted to department of emergency
Jia-yi ZHENG ; Fu-peng WU ; Hai-su LU ; Yu-qi TAO ; Ke-yu SUN
Fudan University Journal of Medical Sciences 2025;52(3):416-423
Objective To develop an objective and precise prognostic model for assessing severity and prognosis in elderly patients with community-acquired pneumonia(CAP)admitted to the emergency department.Methods A retrospective analysis was conducted on elderly patients with CAP admitted to Department of Emergency,Minhang Hospital,Fudan University between Jun 2018 and Dec 2020.With the primary outcome being the 30-day in-hospital mortality rate of elderly CAP patients,four systemic inflammatory response markers,including the neutrophil-to-lymphocyte ratio(NLR),monocyte-to-lymphocyte ratio(MLR),platelet-to-lymphocyte ratio(PLR),and systemic immune-inflammation index(SII)were evaluated using univariate and multivariate Logistic regression analyses.The predictive performance of different scoring systems was compared.Results A total of 421 elderly CAP cases were enrolled.The results of the multivariate Logistic regression analysis demonstrated that NLR was an independent risk factor for elderly inpatients with CAP.We combined NLR with the existing CURB-65 score for joint optimization to construct a scoring system or a clinical prognosis model,by quantifying and assigning optimal cut-off value of 11.4 for NLR,and established the NLR+CURB-65 score.The ROC curve was constructed to compare the areas under the curve of the three different scoring systems(NLR,CURB-65,and NLR+CURB-65).The area under the curve of the NLR+CURB-65 score was significantly higher than that of the CURB-65 score.Based on the optimal cut-off value of 3 for NLR+CURB-65 score,the patients were stratified into high-risk group(n=188)and low-risk group(n=233).The K-M survival curve was utilized and indicated that compared with high-risk group,low-risk group had a lower mortality rate and a higher discharge rate.Conclusion For elderly emergency hospitalized patients with CAP,the combination of NLR and CURB-65 score showed high predictive value for assessing disease severity and prognosis.
3.Comparative analysis of computer-programmed versus artificial right arm blood pressure measurement in detecting hypertension among elderly individuals
Zhao YUAN ; Linglin XIA ; Tao WANG ; Huihui BAO ; Hai SU
Chinese Journal of Cardiology 2025;53(1):37-41
Objective:To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals.Method:This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled. Manual blood pressure measurements were performed on the right arm using an electronic sphygmomanometer, while standardized dual-arm synchronized blood pressure assessments were conducted using the CCBPM. Blood pressure data were recorded from three sources: manual measurement on the right arm; the first CCBPM measurement on the arm with higher systolic blood pressure (CCBPM single); and the mean blood pressure of the arm with higher systolic blood pressure from two (if the difference between the first two measurements was less than 5 mmHg, 1 mmHg=0.133 kPa) or three (if the difference exceeded 5 mmHg) CCBPM measurements (CCBPM mean). Hypertension detection rates from these three datasets were compared. Subgroup analysis was performed according to age (60-74 years old as the elderly group,≥75 years old as the senior group) and gender. Intra-group correlation coefficient ( ICC) was analyzed to evaluate the consistency of blood pressure data of different blood pressure measurement methods, and Kappa value was analyzed to evaluate the consistency of hypertension classification determined by different blood pressure measurement methods. Results:A total of 1 498 participants were enrolled, aged (71.30±6.83) years old, including 678 males (45.26%). The blood pressure and heart rate measured by the artificial right arm blood pressure measurement were higher than those measured by CCBPM single (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (135.31±18.98)/(81.23±10.51) mmHg; heart rate: (75.76±11.72) beats/min vs.(72.94±11.21) beats/min) and CCBPM mean (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (134.64±18.39)/(80.28±9.78) mmHg; heart rate: (75.76±11.72) beats/min vs. (72.87±10.70) beats/min, all P<0.05). The detection rate of hypertension determined by CCBPM mean was significantly lower than that of artificial right arm (40.25% (603/1 498) vs.54.34% (814/1 498)) and CCBPM single (40.25% (603/1 498) vs. 44.79% (671/1 498), all P<0.05). Subgroup analysis showed that that the detection rate of hypertension determined by CCBPM mean was lower than that measured by artificial right arm regardless of gender and age (all P<0.05). The consistency of blood pressure data between artificial right arm and the CCBPM mean was moderate (systolic blood pressure: ICC=0.70; diastolic blood pressure: ICC=0.62), with less consistent classification ( Kappa=0.37). The consistency of blood pressure data between CCBPM single and CCBPM mean is extremely high (systolic blood pressure: ICC=0.94; diastolic blood pressure: ICC=0.91), with highly consistent classification ( Kappa=0.74). Conclusions:Artificial right arm blood pressure measurement in physical examinations may overestimate the hypertension detection rate, and the standardized dual-arm synchronized blood pressure measurement using CCBPM can reduce irregular blood pressure measurement.
4.Prognostic value of neutrophil-to-lymphocyte ratio combined with CURB-65 score for elderly patients with community-acquired pneumonia admitted to department of emergency
Jia-yi ZHENG ; Fu-peng WU ; Hai-su LU ; Yu-qi TAO ; Ke-yu SUN
Fudan University Journal of Medical Sciences 2025;52(3):416-423
Objective To develop an objective and precise prognostic model for assessing severity and prognosis in elderly patients with community-acquired pneumonia(CAP)admitted to the emergency department.Methods A retrospective analysis was conducted on elderly patients with CAP admitted to Department of Emergency,Minhang Hospital,Fudan University between Jun 2018 and Dec 2020.With the primary outcome being the 30-day in-hospital mortality rate of elderly CAP patients,four systemic inflammatory response markers,including the neutrophil-to-lymphocyte ratio(NLR),monocyte-to-lymphocyte ratio(MLR),platelet-to-lymphocyte ratio(PLR),and systemic immune-inflammation index(SII)were evaluated using univariate and multivariate Logistic regression analyses.The predictive performance of different scoring systems was compared.Results A total of 421 elderly CAP cases were enrolled.The results of the multivariate Logistic regression analysis demonstrated that NLR was an independent risk factor for elderly inpatients with CAP.We combined NLR with the existing CURB-65 score for joint optimization to construct a scoring system or a clinical prognosis model,by quantifying and assigning optimal cut-off value of 11.4 for NLR,and established the NLR+CURB-65 score.The ROC curve was constructed to compare the areas under the curve of the three different scoring systems(NLR,CURB-65,and NLR+CURB-65).The area under the curve of the NLR+CURB-65 score was significantly higher than that of the CURB-65 score.Based on the optimal cut-off value of 3 for NLR+CURB-65 score,the patients were stratified into high-risk group(n=188)and low-risk group(n=233).The K-M survival curve was utilized and indicated that compared with high-risk group,low-risk group had a lower mortality rate and a higher discharge rate.Conclusion For elderly emergency hospitalized patients with CAP,the combination of NLR and CURB-65 score showed high predictive value for assessing disease severity and prognosis.
5.Research advances of CXCL12/CXCR4 in the rheumatoid arthritis pathogenesis
Hong-mei YANG ; Hao-lin LI ; Juan-juan YANG ; Xiao-jun SU ; Hai-tao LEI ; Dong-sheng LU ; Li-li KAN ; Peng-fei TAO ; Hai-dong WANG
Chinese Pharmacological Bulletin 2025;41(2):230-234
Rheumatoid arthritis(RA)is a chronic autoimmune disease of unknown etiology that can cause joint destruction and deformity.As a small molecule cytokine,the chemokine C-X-C motif chemokine ligand 12(CXCL12)regulates the pathogenesis of rheumatoid arthritis by binding to the specific receptor CXC chemokine receptor 4(CXCR4).Therefore,based on the bio-logical characteristics of CXCL12 and CXCR4,this paper intro-duces the pathogenesis of CXCL12/CXCR4 in RA and summari-zes the progress in RA-related research,with the aim of providing clinical value for understanding the pathogenesis of RA and de-veloping novel therapeutic targets.
6.Research advances of CXCL12/CXCR4 in the rheumatoid arthritis pathogenesis
Hong-mei YANG ; Hao-lin LI ; Juan-juan YANG ; Xiao-jun SU ; Hai-tao LEI ; Dong-sheng LU ; Li-li KAN ; Peng-fei TAO ; Hai-dong WANG
Chinese Pharmacological Bulletin 2025;41(2):230-234
Rheumatoid arthritis(RA)is a chronic autoimmune disease of unknown etiology that can cause joint destruction and deformity.As a small molecule cytokine,the chemokine C-X-C motif chemokine ligand 12(CXCL12)regulates the pathogenesis of rheumatoid arthritis by binding to the specific receptor CXC chemokine receptor 4(CXCR4).Therefore,based on the bio-logical characteristics of CXCL12 and CXCR4,this paper intro-duces the pathogenesis of CXCL12/CXCR4 in RA and summari-zes the progress in RA-related research,with the aim of providing clinical value for understanding the pathogenesis of RA and de-veloping novel therapeutic targets.
7.Safety and accuracy of robotic-assisted screw placement in the treatment of adolescent idiopathic scoliosis
Xinuo ZHANG ; Qingjun SU ; Dongyue LI ; Luming TAO ; Yong HAI
Chinese Journal of Postgraduates of Medicine 2025;48(1):17-23
Objective:To compare the safety and accuracy between robotic-assisted screw placement and free-hand screw placement in adolescent idiopathic scoliosis (AIS) surgery.Methods:The clinical data of 69 AIS patients underwent posterior spinal scoliosis orthomorphia from December 2021 to October 2023 in Beijing Chaoyang Hospital, Capital Medical University were retrospectively analyzed. Among them, 37 patients underwent robot-assisted screw placement (robot group), and 32 patients underwent fluoroscopy-assisted free-hand screw placement (free-hand group). The basic information of surgery (operation time, intraoperative blood loss, intraoperative radiation exposure time, postoperative hospital stay and postoperative complications), screw placement indexes (single screw placement time and accuracy of screw placement) and imaging indexes (main curve correction rate, kyphotic change and lumbar lordosis change) were compared between two groups. The ln curve regression analysis method was used to evaluate the learning curve of robot-assisted screw placement therapy for AIS.Results:A total of 716 screws were placed in 32 patients of free-hand group, and 766 screws in 37 patients of robot group. The operation time, intraoperative radiation exposure time, single screw placement time and accuracy of screw placement in robot group were significantly higher than those in free-hand group: (272.30 ± 67.98) min vs. (221.66 ± 67.32) min, (149.81 ± 57.21) s vs. (116.03 ± 63.10) s, (497.97 ± 51.74) s vs. (381.47 ± 46.58) s and 97.91% (750/766) vs. 91.48% (655/716), and there were statistical differences ( P<0.01 or <0.05); there were no statistical differences in intraoperative blood loss, postoperative hospital stay, incidence of neurological complications, incidence of incision infection and number of screw between two groups ( P>0.05). There were no statistical differences in the main curve correction rate, kyphotic change and lumbar lordosis change between two groups ( P>0.05). When the fitting degree was the highest ( R2 = 0.729, P<0.01), the fitting equation was y = - 50.93ln x + 634.7 ( x was the number of operation, and y was the single screw placement time), and the number of vertices was 12 cases. The robot group was divided into three subgroups according to the order of surgery, subgroup A consisted of 12 patients who underwent the surgery from first to twelfth, subgroup B consisted of 12 patients who underwent the surgery from thirteenth to twenty-fourth, and subgroup C consisted of 13 patients who underwent the surgery from twenty-fifth to thirty-seventh. Among them, the single screw placement time in subgroup A was significantly longer than that in subgroup B and subgroup C: (560.92 ± 35.03) s vs. (465.75 ± 21.20) and (469.62 ± 24.94) s, and there was statistical difference ( P<0.05); there was no statistical difference between subgroup B and subgroup C ( P>0.05). Conclusions:Robot-assisted screw placement for AIS can effectively improve the accuracy of screw placement without affecting deformity correction, but it can increase screw placement time, operation time and radiation exposure time. A smooth learning curve is obtained after performing 12 procedures.
8.Comparative analysis of computer-programmed versus artificial right arm blood pressure measurement in detecting hypertension among elderly individuals
Zhao YUAN ; Linglin XIA ; Tao WANG ; Huihui BAO ; Hai SU
Chinese Journal of Cardiology 2025;53(1):37-41
Objective:To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals.Method:This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled. Manual blood pressure measurements were performed on the right arm using an electronic sphygmomanometer, while standardized dual-arm synchronized blood pressure assessments were conducted using the CCBPM. Blood pressure data were recorded from three sources: manual measurement on the right arm; the first CCBPM measurement on the arm with higher systolic blood pressure (CCBPM single); and the mean blood pressure of the arm with higher systolic blood pressure from two (if the difference between the first two measurements was less than 5 mmHg, 1 mmHg=0.133 kPa) or three (if the difference exceeded 5 mmHg) CCBPM measurements (CCBPM mean). Hypertension detection rates from these three datasets were compared. Subgroup analysis was performed according to age (60-74 years old as the elderly group,≥75 years old as the senior group) and gender. Intra-group correlation coefficient ( ICC) was analyzed to evaluate the consistency of blood pressure data of different blood pressure measurement methods, and Kappa value was analyzed to evaluate the consistency of hypertension classification determined by different blood pressure measurement methods. Results:A total of 1 498 participants were enrolled, aged (71.30±6.83) years old, including 678 males (45.26%). The blood pressure and heart rate measured by the artificial right arm blood pressure measurement were higher than those measured by CCBPM single (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (135.31±18.98)/(81.23±10.51) mmHg; heart rate: (75.76±11.72) beats/min vs.(72.94±11.21) beats/min) and CCBPM mean (blood pressure: (140.09±17.19)/(82.40±10.93) mmHg vs. (134.64±18.39)/(80.28±9.78) mmHg; heart rate: (75.76±11.72) beats/min vs. (72.87±10.70) beats/min, all P<0.05). The detection rate of hypertension determined by CCBPM mean was significantly lower than that of artificial right arm (40.25% (603/1 498) vs.54.34% (814/1 498)) and CCBPM single (40.25% (603/1 498) vs. 44.79% (671/1 498), all P<0.05). Subgroup analysis showed that that the detection rate of hypertension determined by CCBPM mean was lower than that measured by artificial right arm regardless of gender and age (all P<0.05). The consistency of blood pressure data between artificial right arm and the CCBPM mean was moderate (systolic blood pressure: ICC=0.70; diastolic blood pressure: ICC=0.62), with less consistent classification ( Kappa=0.37). The consistency of blood pressure data between CCBPM single and CCBPM mean is extremely high (systolic blood pressure: ICC=0.94; diastolic blood pressure: ICC=0.91), with highly consistent classification ( Kappa=0.74). Conclusions:Artificial right arm blood pressure measurement in physical examinations may overestimate the hypertension detection rate, and the standardized dual-arm synchronized blood pressure measurement using CCBPM can reduce irregular blood pressure measurement.
9.A multi-center epidemiological study on pneumococcal meningitis in children from 2019 to 2020
Cai-Yun WANG ; Hong-Mei XU ; Gang LIU ; Jing LIU ; Hui YU ; Bi-Quan CHEN ; Guo ZHENG ; Min SHU ; Li-Jun DU ; Zhi-Wei XU ; Li-Su HUANG ; Hai-Bo LI ; Dong WANG ; Song-Ting BAI ; Qing-Wen SHAN ; Chun-Hui ZHU ; Jian-Mei TIAN ; Jian-Hua HAO ; Ai-Wei LIN ; Dao-Jiong LIN ; Jin-Zhun WU ; Xin-Hua ZHANG ; Qing CAO ; Zhong-Bin TAO ; Yuan CHEN ; Guo-Long ZHU ; Ping XUE ; Zheng-Zhen TANG ; Xue-Wen SU ; Zheng-Hai QU ; Shi-Yong ZHAO ; Lin PANG ; Hui-Ling DENG ; Sai-Nan SHU ; Ying-Hu CHEN
Chinese Journal of Contemporary Pediatrics 2024;26(2):131-138
Objective To investigate the clinical characteristics and prognosis of pneumococcal meningitis(PM),and drug sensitivity of Streptococcus pneumoniae(SP)isolates in Chinese children.Methods A retrospective analysis was conducted on clinical information,laboratory data,and microbiological data of 160 hospitalized children under 15 years old with PM from January 2019 to December 2020 in 33 tertiary hospitals across the country.Results Among the 160 children with PM,there were 103 males and 57 females.The age ranged from 15 days to 15 years,with 109 cases(68.1% )aged 3 months to under 3 years.SP strains were isolated from 95 cases(59.4% )in cerebrospinal fluid cultures and from 57 cases(35.6% )in blood cultures.The positive rates of SP detection by cerebrospinal fluid metagenomic next-generation sequencing and cerebrospinal fluid SP antigen testing were 40% (35/87)and 27% (21/78),respectively.Fifty-five cases(34.4% )had one or more risk factors for purulent meningitis,113 cases(70.6% )had one or more extra-cranial infectious foci,and 18 cases(11.3% )had underlying diseases.The most common clinical symptoms were fever(147 cases,91.9% ),followed by lethargy(98 cases,61.3% )and vomiting(61 cases,38.1% ).Sixty-nine cases(43.1% )experienced intracranial complications during hospitalization,with subdural effusion and/or empyema being the most common complication[43 cases(26.9% )],followed by hydrocephalus in 24 cases(15.0% ),brain abscess in 23 cases(14.4% ),and cerebral hemorrhage in 8 cases(5.0% ).Subdural effusion and/or empyema and hydrocephalus mainly occurred in children under 1 year old,with rates of 91% (39/43)and 83% (20/24),respectively.SP strains exhibited complete sensitivity to vancomycin(100% ,75/75),linezolid(100% ,56/56),and meropenem(100% ,6/6).High sensitivity rates were also observed for levofloxacin(81% ,22/27),moxifloxacin(82% ,14/17),rifampicin(96% ,25/26),and chloramphenicol(91% ,21/23).However,low sensitivity rates were found for penicillin(16% ,11/68)and clindamycin(6% ,1/17),and SP strains were completely resistant to erythromycin(100% ,31/31).The rates of discharge with cure and improvement were 22.5% (36/160)and 66.2% (106/160),respectively,while 18 cases(11.3% )had adverse outcomes.Conclusions Pediatric PM is more common in children aged 3 months to under 3 years.Intracranial complications are more frequently observed in children under 1 year old.Fever is the most common clinical manifestation of PM,and subdural effusion/emphysema and hydrocephalus are the most frequent complications.Non-culture detection methods for cerebrospinal fluid can improve pathogen detection rates.Adverse outcomes can be noted in more than 10% of PM cases.SP strains are high sensitivity to vancomycin,linezolid,meropenem,levofloxacin,moxifloxacin,rifampicin,and chloramphenicol.[Chinese Journal of Contemporary Pediatrics,2024,26(2):131-138]
10.Clinical study of lumbar stability after unilateral biportal endoscopy in the treatment of degenerative lumbar diseases
Dongyue LI ; Qingjun SU ; Xinuo ZHANG ; Luming TAO ; Yong HAI
Chinese Journal of Surgery 2024;62(3):187-193
Objectives:To investigate the clinical efficacy of unilateral biportal endoscopy (UBE) in the treatment of degenerative lumbar disease (DLD) and its impact on postoperative lumbar stability.Methods:This is a retrospective case series study. A total of 109 cases of DLD treated with UBE in the Department of Orthopaedic, Beijing Chaoyang Hospital Affiliated to Capital Medical University from July 2020 to June 2022 were analyzed retrospectively. There were 47 males and 62 females, aged (53.3±8.2) years (range: 21 to 80 years). The surgical segments were single segment in 80 cases, two segments in 25 cases, and three segments in 4 cases. The low back pain and leg pain of visual analogue scale (VAS), Japanese Orthopaedic Association (JOA) score and Oswestry disability index (ODI) were evaluated before and after operation. The modified MacNab criteria were used for evaluation of the clinical consequences. Postoperative three-dimensional lumbar CT was performed to observe the preservation of the facet joints and the angle of the medial surface of the facetectomy(β angle). At 12 months after surgery, X ray of the flexion and extension lumbar spine were reviewed. The comparison and analysis of the data were conducted using paired sample t tests or generalized estimation equations. Results:All 109 patients underwent operative procedures successfully. The operation time was (94.5±37.1) minutes (range:56 to 245 minutes), the times of X ray was 6.8±4.0 (range:4 to 16 times), and the days of hospitalization was (5.3±3.7) days (range:4 to 14 days). Complications included dural tears in 4 cases, transient lower limb numbness in 4 cases, epidural hematoma in 2 case. The follow-up time was (19.6±7.2) months (range:12 to 36 months). The postoperative low back pain VAS, leg pain VAS, JOA score and ODI were significantly improved(all P<0.05). According to the modified MacNab criteria, the excellent and good rate was 88.99%(97/109) at 12 months after surgery. One case underwent revision surgery because of recurrent lumbar disc herniation. In term of radiographic evaluation, the area of the surgical side facet joints after UBE surgery was reserved more than 60%. The β angle was less than 90° in all patients. After 12 months of surgery, there was no surgical segment instability or spondylolisthesis by the X-ray of the flexion and extension lumbar spine. Conclusion:UBE can achieve satisfactory clinical efficacy in the treatment of DLD, and maintain the stability of the lumbar spine.

Result Analysis
Print
Save
E-mail