1.Rapid characterization and identification of non-volatile components in Rhododendron tomentosum by UHPLC-Q-TOF-MS method.
Su-Ping XIAO ; Long-Mei LI ; Bin XIE ; Hong LIANG ; Qiong YIN ; Jian-Hui LI ; Jie DU ; Ji-Yong WANG ; Run-Huai ZHAO ; Yan-Qin XU ; Yun-Bo SUN ; Zong-Yuan LU ; Peng-Fei TU
China Journal of Chinese Materia Medica 2025;50(11):3054-3069
This study aimed to characterize and identify the non-volatile components in aqueous and ethanolic extracts of the stems and leaves of Rhododendron tomentosum by using sensitive and efficient ultra-performance liquid chromatography-quadrupole-time of flight mass spectrometry(UHPLC-Q-TOF-MS) combined with a self-built information database. By comparing with reference compounds, analyzing fragment ion information, searching relevant literature, and using a self-built information database, 118 compounds were identified from the aqueous and ethanolic extracts of R. tomentosum, including 35 flavonoid glycosides, 15 phenolic glycosides, 12 flavonoids, 7 phenolic acids, 7 phenylethanol glycosides, 6 tannins, 6 phospholipids, 5 coumarins, 5 monoterpene glycosides, 6 triterpenes, 3 fatty acids, and 11 other types of compounds. Among them, 102 compounds were reported in R. tomentosum for the first time, and 36 compounds were identified by comparing them with reference compounds. The chemical components in the ethanolic and aqueous extracts of R. tomentosum leaves and stems showed slight differences, with 84 common chemical components accounting for 71.2% of the total 118 compounds. This study systematically characterized and identified the non-volatile chemical components in the ethanolic and aqueous extracts of R. tomentosum for the first time. The findings provide a reference for active ingredient research, quality control, and product development of R. tomentosum.
Rhododendron/chemistry*
;
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Mass Spectrometry/methods*
;
Plant Leaves/chemistry*
2.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
3.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
4.Clinical trial of brexpiprazole in the treatment of adults with acute schizophrenia
Shu-Zhe ZHOU ; Liang LI ; Dong YANG ; Jin-Guo ZHAI ; Tao JIANG ; Yu-Zhong SHI ; Bin WU ; Xiang-Ping WU ; Ke-Qing LI ; Tie-Bang LIU ; Jie LI ; Shi-You TANG ; Li-Li WANG ; Xue-Yi WANG ; Yun-Long TAN ; Qi LIU ; Uki MOTOMICHI ; Ming-Ji XIAN ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(5):654-658
Objective To evaluate the efficacy and safety of brexpiprazole in treating acute schizophrenia.Methods Patients with schizophrenia were randomly divided into treatment group and control group.The treatment group was given brexpiprozole 2-4 mg·d-1 orally and the control group was given aripiprazole 10-20 mg·d-1orally,both were treated for 6 weeks.Clinical efficacy of the two groups,the response rate at endpoint,the changes from baseline to endpoint of Positive and Negative Syndrome Scale(PANSS),Clinical Global Impression-Improvement(CGI-S),Personal and Social Performance scale(PSP),PANSS Positive syndrome subscale,PANSS negative syndrome subscale were compared.The incidence of treatment-related adverse events in two groups were compared.Results There were 184 patients in treatment group and 186 patients in control group.After treatment,the response rates of treatment group and control group were 79.50%(140 cases/184 cases)and 82.40%(150 cases/186 cases),the scores of CGI-I of treatment group and control group were(2.00±1.20)and(1.90±1.01),with no significant difference(all P>0.05).From baseline to Week 6,the mean change of PANSS total score wese(-30.70±16.96)points in treatment group and(-32.20±17.00)points in control group,with no significant difference(P>0.05).The changes of CGI-S scores in treatment group and control group were(-2.00±1.27)and(-1.90±1.22)points,PSP scores were(18.80±14.77)and(19.20±14.55)points,PANSS positive syndrome scores were(-10.30±5.93)and(-10.80±5.81)points,PANSS negative syndrome scores were(-6.80±5.98)and(-7.30±5.15)points,with no significant difference(P>0.05).There was no significant difference in the incidence of treatment-related adverse events between the two group(69.00%vs.64.50%,P>0.05).Conclusion The non-inferiority of Brexpiprazole to aripiprazole was established,with comparable efficacy and acceptability.
5.Functionalized Cadmium-Metal Organic Framework Materials with Azo Bonds for Highly Sensitive Electrochemical Detection of 4-Aminophenol
Lu XU ; Tian-Tian MA ; Yi-Yan BAI ; Jing SU ; Yun-Long FU ; Hai-Ying YANG ; Wen-Juan JI
Chinese Journal of Analytical Chemistry 2024;52(4):587-596
The presence of 4-aminophenol(4-AP)in wastewater from the pharmaceutical industry is a common occurrence due to its role as a byproduct or intermediate during the hydrolysis process of paracetamol metabolism,resulting in significant water pollution.Therefore,it is crucial to employ a straightforward and reliable analytical approach for detecting 4-AP in the environment.In this study,a specific type of metal-organic framework(MOF)material called[Cd4(ABTC)2(H2O)12]n(SXNU-4-Cd,H4ABTC=3,3′,5,5′-azobenzene tetracarboxylic acid)was successfully synthesized,which exhibited a unique two-dimensional layered structure consisting of three intertwined spiral chains forming a distinctive″twist braid″.These layers underwent π-π stacking,creating three-dimensional channels with azo bonds decorating the channel walls.This p-π interaction significantly enhanced the adsorption capacity of SXNU-4-Cd towards 4-AP,thereby improving its recognition sensitivity.The fabricated SXNU-4-Cd/GCE sensor showed high sensitivity towards 4-AP in the linear concentration range of 0.1-130 μmol/L,with a detection limit of 8.6 nmol/L,and also exhibited good anti-interference capability,reproducibility and stability.The SXNU-4-Cd/GCE sensor was successfully used for detecting 4-AP in lake water sample,with spiked recoveries of 95.9%-102.8%.This study introduced a novel technique that utilized pure Cd-MOFs to develop electrochemical sensor capable of effectively detecting 4-AP in water samples.
6.Risk factors for bronchopulmonary dysplasia in twin preterm infants:a multicenter study
Yu-Wei FAN ; Yi-Jia ZHANG ; He-Mei WEN ; Hong YAN ; Wei SHEN ; Yue-Qin DING ; Yun-Feng LONG ; Zhi-Gang ZHANG ; Gui-Fang LI ; Hong JIANG ; Hong-Ping RAO ; Jian-Wu QIU ; Xian WEI ; Ya-Yu ZHANG ; Ji-Bin ZENG ; Chang-Liang ZHAO ; Wei-Peng XU ; Fan WANG ; Li YUAN ; Xiu-Fang YANG ; Wei LI ; Ni-Yang LIN ; Qian CHEN ; Chang-Shun XIA ; Xin-Qi ZHONG ; Qi-Liang CUI
Chinese Journal of Contemporary Pediatrics 2024;26(6):611-618
Objective To investigate the risk factors for bronchopulmonary dysplasia(BPD)in twin preterm infants with a gestational age of<34 weeks,and to provide a basis for early identification of BPD in twin preterm infants in clinical practice.Methods A retrospective analysis was performed for the twin preterm infants with a gestational age of<34 weeks who were admitted to 22 hospitals nationwide from January 2018 to December 2020.According to their conditions,they were divided into group A(both twins had BPD),group B(only one twin had BPD),and group C(neither twin had BPD).The risk factors for BPD in twin preterm infants were analyzed.Further analysis was conducted on group B to investigate the postnatal risk factors for BPD within twins.Results A total of 904 pairs of twins with a gestational age of<34 weeks were included in this study.The multivariate logistic regression analysis showed that compared with group C,birth weight discordance of>25%between the twins was an independent risk factor for BPD in one of the twins(OR=3.370,95%CI:1.500-7.568,P<0.05),and high gestational age at birth was a protective factor against BPD(P<0.05).The conditional logistic regression analysis of group B showed that small-for-gestational-age(SGA)birth was an independent risk factor for BPD in individual twins(OR=5.017,95%CI:1.040-24.190,P<0.05).Conclusions The development of BPD in twin preterm infants is associated with gestational age,birth weight discordance between the twins,and SGA birth.
7.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
8.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
9.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
10.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.

Result Analysis
Print
Save
E-mail