1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Clinical Advantages of Traditional Chinese Medicine in Treatment of Childhood Simple Obesity: Insights from Expert Consensus
Qi ZHANG ; Yingke LIU ; Xiaoxiao ZHANG ; Guichen NI ; Heyin XIAO ; Junhong WANG ; Liqun WU ; Zhanfeng YAN ; Kundi WANG ; Jiajia CHEN ; Hong ZHENG ; Xinying GAO ; Liya WEI ; Qiang HE ; Qian ZHAO ; Huimin SU ; Zhaolan LIU ; Dafeng LONG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):238-245
Childhood simple obesity has become a significant public health issue in China. Modern medicine primarily relies on lifestyle interventions and often suffers from poor long-term compliance, while pharmacological options are limited and associated with potential adverse effects. Traditional Chinese Medicine (TCM) has a long history in the prevention and management of this condition, demonstrating eight distinct advantages, including systematic theoretical foundation, diversified therapeutic approaches, definite therapeutic efficacy, high safety profile, good patient compliance, comprehensive intervention strategies, emphasis on prevention, and stepwise treatment protocols. Additionally, TCM is characterized by six distinctive features: the use of natural medicinal substances, non-invasive external therapies, integration of medicinal dietetics, simple exercise regimens, precise syndrome differentiation, and diverse dosage forms. By combining internal and external treatments, TCM facilitates individualized regimen adjustment and holistic regulation, demonstrating remarkable effects in improving obesity-related metabolic indicators, regulating constitutional imbalance, and promoting healthy behaviors. However, challenges remain, such as inconsistent operational standards, insufficient high-quality clinical evidence, and a gap between basic research and clinical application. Future efforts should focus on accelerating the standardization of TCM diagnosis and treatment, conducting multicenter randomized controlled trials, and fostering interdisciplinary integration, so as to enhance the scientific validity and international recognition of TCM in the prevention and treatment of childhood obesity.
4.Alleviating ulcerative colitis with Baitouweng decoction through Nrf2/HO-1 pathway activation and HMGB1 downregulation
Wei-na ZHU ; Chun-hua MA ; Jie RUAN ; Fu-qiong ZHOU ; Ya-jie ZHANG ; Hong-yan LONG
Chinese Pharmacological Bulletin 2025;41(1):186-192
Aim To explore the antioxidative effect of the Chinese medicine Baitouweng(BTW)on treating ulcerative colitis(UC).Methods Sixty male mice were randomly divided into six groups:control,dextran sulfate sodium(DSS)(3 g·105 L-1),BTW(20,10,and 5 g·kg-1),and 5-aminosalicylic acid(5-ASA)(800 mg·kg-1).UC model was constructed by 3%DSS for seven days,and the UC model was given by ga-vage once daily from the 5 th day of modeling for seven days.Results BTW effectively reduced the symptoms and histopathological scores of UC mice.Additionally,it downregulated the inflammatory factors,interleukin(IL)-6 and IL-1 β,the immunoglobulins vascular cell adhesion molecule 1 and intercellular adhesion mole-cule 1,and metalloprotease matrix metallopeptidase 9.Moreover,it downregulated high mobility group box 1 protein.Furthermore,it inhibited the nuclear factor er-ythroid 2-related factor 2(Nrf2)/heme oxygenase-1(HO-1)pathway.Conclusions BTW improves the general condition,inflammatory indexes and oxidative stress level,and its mechanism may be related to inhib-iting the level of HMGB1 to regulate the Nrf-2/HO-1 signaling pathway and rescue intestinal barrier-related protein expression.
5.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
6.Single position left transthoracic and esophageal hiatal approach for Siewert type Ⅱ adenocarcinoma of the esophagogastric junction:a retrospective cohort analysis
Hai-Tao WEI ; Meng-Yao WANG ; Yang-Yang LIU ; Feng ZHANG ; Bao-Li HU ; Hai-Feng ZHANG ; Xiao-Long WANG ; Dong-Hong ZHANG ; Li LI
Medical Journal of Chinese People's Liberation Army 2025;50(10):1270-1276
Objective To explore the validity and feasibility of the left transthoracic and esophageal hiatal approach for Siewert type Ⅱ adenocarcinoma of the esophagogastric junction under a single position.Methods The clinical data of 64 patients with Siewert type Ⅱ AEG(single position transthoracic approach group)treated with the left transthoracic and esophageal hiatal approach under a single position and 56 patients with the laparoscopic transesophageal slit approach(transabdominal approach group)in the Department of Thoracic Surgery,Huaihe Hospital of Henan University,from January 2017 to December 2018 were retrospectively analyzed.The clinical and pathological data,perioperative indicators(operation time,intraoperative blood loss,postoperative first ambulation time,postoperative first peristalsis time,postoperative drainage volume at 3 d,incidence of postoperative complications,postoperative hospital stay),postoperative complications(positive surgical margin,proximal esophageal resection margin,tumor diameter,total number of dissected lymph nodes,positive lymph node dissection rate,postoperative histopathology,and TNM staging of tumor pathology),and survival indicators(tumor recurrence and metastasis rate and survival at 1 month,3 months,6 months,1 year,3 years,5 years after surgery)were compared between the two groups.Kaplan-Meier method was used to analyze the postoperative survival rate of the two groups.Univariate analysis using χ2 test was employed to analyze factors influencing 5-year postoperative survival rate in Siewert type Ⅱ AEG patients.Results No significant difference was observed in clinical and pathological data,such as gender,age,American Society of Anesthesiologists(ASA)grade,tumor differentiation,pTNM stage,and tumor diameter between the two groups(P>0.05).No significant differences were noted in intraoperative blood loss,incidence of postoperative complications,and survival rates at 1 month,3 months,6 months,1 year,and 3 years after surgery between the two groups(P>0.05).The single position transthoracic approach group exhibited a higher postoperative drainage volume at 3 d compared to the transabdominal approach group(P<0.001),a shorter surgical time(P<0.001),a longer time to first mobilization,first intestinal peristalsis,and hospital stay after surgery(P<0.01),a longer proximal esophageal margin(P<0.001),a higher total number of lymph node dissections(P<0.001),and a higher positive lymph node dissection rate(P<0.05)than the transabdominal approach group.The 5-year recurrence-free survival rate of the single position transthoracic approach group was higher than that of the transabdominal approach group,with a statistically significant difference(P=0.013).The Kaplan-Meier survival curve showed no statistically significant difference in the 5-year overall survival rate between the two groups of patients after surgery(P=0.456).The results of univariate analysis indicated that there are significant relationships between tumor differentiation degree,pTNM stage,tumor diameter,and lymph node positivity rate with the 5-year postoperative survival rate in Siewert type Ⅱ AEG patients(P<0.05).Conclusion Siewert type Ⅱ AEG patients can be treated with the left transthoracic and esophageal hiatal approach under a single position,achieving the same effect as laparoscopic transesophageal slit approach,and it can be actively promoted as a complementary choice of operation in the clinic.
7.Engineering CHO Cell Lines to Stably Express B4GALT1,ST6GAL1,and GnTⅢ with Site-directed Integration
Xian-Hong LI ; Run-Qing JIA ; You-Liang WANG ; Wei-Ling MAN ; Tian-Hao ZHU ; Xin-Long YAN ; Yan-Li LIN
Chinese Journal of Biochemistry and Molecular Biology 2025;41(4):576-585
Glycoengineering was carried out in the mammalian cell line CHO for the production of pro-tein-based drugs.Firstly,the genome sequence of the Rosa26 locus of CHO cells was determined,the gRNA sequences were designed,and the landing pad was integrated into the Rosa26 locus of CHO cells by CRISPR/Cas9 technology.Three targeting vectors co-expressed by glycosyltransferases,which are β-1,4 galactosyltransferase(B4GALT1),α-2,6-sialyltransferase 1(ST6GAL1)and N-acetaminoglycosyl-transferase Ⅲ(GnT Ⅲ),were constructed by overlapping PCR and seamless ligation technology,and the three glycosyltransferase genes were integrated into the CHO Rosa26 locus by Cre enzyme-mediated cassette exchange technology.PCR confirmed that three glycosyltransferases had been successfully site-directed integrated into the Rosa26 site.The mRNA expression levels of the three glycosyltransferases were more than 50 000-fold by qRT-PCR,and the protein expression levels of the three glycosyltrans-ferases were more than 4-fold via western blotting(P<0.001).A CHO-engineered cell line with three glycosyltransferases integrated into Rosa26 site was successfully constructed.
8.Analysis of risk factors for noncontiguous spinal fractures in the elderly
Shi-lei TANG ; Hong-wen GU ; Yin HU ; Kang-en HAN ; Hai-long YU ; Zhi-hao ZHANG ; Hong-wei WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):130-133
Objective To explore the risk factors for noncontiguous spinal fractures(NSFs)in the elderly.Methods The clinical data of 614 elderly patients with spinal fracture from January 2013 to December 2019 were analyzed retrospectively.Patients were divided into the NSFs group and the Non-NSFs group according to whether NSFs occurred or not.Univariate analysis and multivariate Logistic regression analysis were used to screen the risk factors of NSFs.Results Univariate analysis showed that female(P=0.003),high-energy violent injury(P=0.032),osteoporosis(P=0.004),fracture in spring(P=0.020),and previous spinal fracture history(P<0.001)were associated with the occurrence of NSFs.Multivariate Logistic regression analysis showed that fracture in spring(P=0.024),previous spinal fracture history(P<0.001)and high-energy violent injury(P=0.038)were the independent risk factors for the occurrence of NSFs in the elderly.Conclusion High-energy violent injury,fracture in spring and previous spinal fracture history are the independent risk factors for the occurrence of NSFs in the elderly.Therefore,elderly patients with the above risk factors should be examined more carefully and comprehensively to avoid missed diagnosis and delayed diagnosis.In order to reduce the incidence of this disease,corresponding measures should be taken according to the preventable risk factors.
9.Establishment and validation of a predictive model for increased drainage volume after open transforaminal lumbar interbody fusion
Yin HU ; Hai-long YU ; Hong-wen GU ; Kang-en HAN ; Shi-lei TANG ; Yuan-hang ZHAO ; Zhi-hao ZHANG ; Jun-chao LI ; Le XING ; Hong-wei WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(11):981-986
Objective To analyze the risk factors for increased drainage volume after open transforaminal lumbar interbody fusion(TLIF),and to establish a predictive model and then validate it.Methods The clinical data of 680 patients who underwent open TLIF at the General Hospital of Northern Theater Command from January 2016 to December 2019 were collected and the patients were randomly divided into the training group(n=476)and the validation group(n=204).Taking the predictive factors screened out by LASSO regression analysis as independent variables,a multivariate Logistic regression predictive model was constructed.The model was internally validated through the receiver operating characteristic(ROC)curve,Hosmer-Lemeshow goodness-of-fit test,and calibration curve,and its clinical utility was assessed via decision curve analysis(DCA).Results LASSO regression analysis screened out four predictive variables:age,number of surgical segments,operative duration,and intraoperative blood loss.The multivariate Logistic regression predictive model demonstrated that age≥60 years,number of surgical segments≥4,operative duration≥2 hours,and intraoperative blood loss≥200 mL were independent influencing factors for the increased postoperative drainage volume in patients undergoing TLIF(P<0.05).ROC curve analysis revealed an area under the curve(AUC)of 0.816(95%CI:0.798 to 0.867)in the training group and 0.783(95%CI:0.685 to 0.823)in the validation group,indicating that the predictive model had good discriminatory ability.Additionally,the Hosmer-Lemeshow goodness-of-fit test and calibration curve indicated that the predictive model had a good degree of fit,and the predicted probability was basically consistent with the actual probability,demonstrating a good calibration.The DCA results confirmed that this predictive model could be applied in clinical practice.Conclusion The risk factors for increased drainage volume after open TLIF include age,number of surgical segments,operative duration,and intraoperative blood loss.The predictive model established based on these factors demonstrates good performance,and it can be applied in clinical guidance for the selection of drainage tube removal time after TLIF.
10.Establishment and validation of a predictive model for increased drainage volume after open transforaminal lumbar interbody fusion
Yin HU ; Hai-long YU ; Hong-wen GU ; Kang-en HAN ; Shi-lei TANG ; Yuan-hang ZHAO ; Zhi-hao ZHANG ; Jun-chao LI ; Le XING ; Hong-wei WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(11):981-986
Objective To analyze the risk factors for increased drainage volume after open transforaminal lumbar interbody fusion(TLIF),and to establish a predictive model and then validate it.Methods The clinical data of 680 patients who underwent open TLIF at the General Hospital of Northern Theater Command from January 2016 to December 2019 were collected and the patients were randomly divided into the training group(n=476)and the validation group(n=204).Taking the predictive factors screened out by LASSO regression analysis as independent variables,a multivariate Logistic regression predictive model was constructed.The model was internally validated through the receiver operating characteristic(ROC)curve,Hosmer-Lemeshow goodness-of-fit test,and calibration curve,and its clinical utility was assessed via decision curve analysis(DCA).Results LASSO regression analysis screened out four predictive variables:age,number of surgical segments,operative duration,and intraoperative blood loss.The multivariate Logistic regression predictive model demonstrated that age≥60 years,number of surgical segments≥4,operative duration≥2 hours,and intraoperative blood loss≥200 mL were independent influencing factors for the increased postoperative drainage volume in patients undergoing TLIF(P<0.05).ROC curve analysis revealed an area under the curve(AUC)of 0.816(95%CI:0.798 to 0.867)in the training group and 0.783(95%CI:0.685 to 0.823)in the validation group,indicating that the predictive model had good discriminatory ability.Additionally,the Hosmer-Lemeshow goodness-of-fit test and calibration curve indicated that the predictive model had a good degree of fit,and the predicted probability was basically consistent with the actual probability,demonstrating a good calibration.The DCA results confirmed that this predictive model could be applied in clinical practice.Conclusion The risk factors for increased drainage volume after open TLIF include age,number of surgical segments,operative duration,and intraoperative blood loss.The predictive model established based on these factors demonstrates good performance,and it can be applied in clinical guidance for the selection of drainage tube removal time after TLIF.

Result Analysis
Print
Save
E-mail