1.Concept, design and clinical application of minimally invasive liver transplantation through laparoscopic combined upper midline incision
Shuhong YI ; Hui TANG ; Kaining ZENG ; Xiao FENG ; Binsheng FU ; Qing YANG ; Jia YAO ; Yang YANG ; Guihua CHEN
Organ Transplantation 2025;16(1):67-73
Objective To explore the technical process and clinical application of laparoscopic combined upper midline incision minimally invasive liver transplantation. Methods A retrospective analysis was conducted on 30 cases of laparoscopic combined upper midline incision minimally invasive liver transplantation. The cases were divided into cirrhosis group (15 cases) and liver failure group (15 cases) based on the primary disease. The surgical and postoperative conditions of the two groups were compared. Results All patients successfully underwent laparoscopic "clockwise" liver resection, with no cases of passive conversion to open surgery or intolerance to pneumoperitoneum. In 6 cases, the right lobe was relatively large, and the right hepatic ligaments could not be completely mobilized. One case required an additional reverse "L" incision during open surgery. All patients successfully completed the liver transplantation, with no major intraoperative bleeding, cardiovascular events, or other occurrences in the 30 patients. The model for end-stage liver disease (MELD) score in the cirrhosis group was lower than that in the liver failure group (P<0.001). There were no statistically significant differences between the two groups in terms of age, surgical time, blood loss, anhepatic phase, or cold ischemia time (all P>0.05). During the perioperative period, there was 1 case of hepatic artery embolism, 1 case of portal vein anastomotic stenosis, no complications of hepatic vein and inferior vena cava, and 3 cases of biliary anastomotic stenosis, all of which occurred in the liver failure group. Conclusions In strictly selected cases, the minimally invasive liver transplantation technique combining laparoscopic hepatectomy with upper midline incision for graft implantation has the advantages of smaller incisions, less bleeding, relatively easier operation, and faster postoperative recovery, which is worthy of clinical promotion and application.
2.Application of middle hepatic vein splitting and reconstruction technique in split liver transplantation from low-age donor livers
Hui TANG ; Binsheng FU ; Qing YANG ; Jia YAO ; Kaining ZENG ; Xiao FENG ; Shuhong YI ; Yang YANG
Organ Transplantation 2025;16(3):453-459
Objective To explore the feasibility and clinical experience of the middle hepatic vein splitting-reconstruction technique in split liver transplantation from low-age donor livers. Methods A retrospective analysis was conducted on the cases of two low-age donor livers that underwent middle hepatic vein splitting-reconstruction, which were transplanted into four child recipients at the Liver Transplantation Center of the Third Affiliated Hospital of Sun Yat-sen University from January 2017 to July 2023. The surgical and postoperative conditions were summarized and analyzed. Results Donor 1 was a 6-year-old and 4-month-old girl with a body weight of 21 kg, and the obtained donor liver weighed 496 g. After splitting, the left and right liver weights were 201 g and 280 g, and transplanted into a 9-month-old boy weighing 6.5 kg and a 9-month-old boy weighing 7.5 kg, respectively. The graft to recipient weight ratio (GRWR) was 3.09% and 3.73%, respectively. Donor 2 was a 5-year-old and 8-month-old boy with a body weight of 19 kg, and the donor liver weighed 673 g. After splitting, the left and right liver weights were 230 g and 400 g, and transplanted into a 13-month-old girl weighing 9.5 kg and a 15-month-old boy weighing 12 kg. The GRWR was 2.42% and 3.33%, respectively. Both donor livers were split ex vivo, with the middle hepatic vein being completely split in the middle and reconstructed using allogeneic iliac vein and iliac artery vascular patches. According to GRWR, none of the 4 transplant livers were reduced in volume. Among the 4 recipients, one died due to postoperative portal vein thrombosis and non-function of the transplant liver, while the other three cases recovered smoothly without early or late complications. Regular follow-up was conducted until July 31, 2023, and liver function recovered well. Conclusions Under the premise of detailed assessment of the donor liver and meticulous intraoperative operation, as well as matching with suitable child recipients, low-age donor livers may be selected for splitting. The complete splitting and reconstruction of the middle hepatic vein in the middle may effectively ensure the adequate venous return of the left and right liver and provide sufficient functional liver volume.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Proportions of memory T cells and expression of their associated cytokines in lymph nodes of mice infected with Echinococcus multilocularis
Yinshi LI ; Duolikun ADILAI ; Bingqing DENG ; Ainiwaer ABIDAN ; Sheng SUN ; Wenying XIAO ; Conghui GE ; Na TANG ; Jing LI ; Hui WANG ; Tao JIANG ; Chuanshan ZHANG
Chinese Journal of Schistosomiasis Control 2025;37(2):136-143
Objective To investigate the effects of Echinococcus multilocularis infection on levels of memory T (Tm) cells and their subsets in lymph nodes of mice at different stages of infection, so as to provide new insights into immunotherapy for alveolarechinococcosis. MethodsTwenty-four C57BL/6J mice aged 6 to 9 weeks were randomly divided into the infection group and the control group, of 12 mice in each group. Mice in the infection group were administered with 3 000 E. multilocularis protoscoleces via portal venous injection, while animals in the control group were administered with an equal volume of physiological saline. Three mice from each group were sacrificed 4, 12 weeks and 24 weeks post-infection, and lymph nodes were sampled and stained with hematoxylin and eosin (HE) to investigate the histopathological changes of mouse lymph nodes in the infection group. The expression and localization of T lymphocyte surface markers CD3, CD4, and CD8 were observed in mouse lymph nodes using immunohistochemical staining. In addition, lymphocyte suspensions were prepared from mouse lymph nodes in both groups at different time points post-infection, and the levels of Tm cell subsets and their secreted cytokines were detected using flow cytometry. Results HE staining showed diffuse structural alterations in the subcapsular cortical and paracortical regions of mouse lymph nodes in the infection group 4 weeks post-infection with E. multilocularis. Immunohistochemical staining detected CD3, CD4 and CD8 expression in mouse lymph nodes in both groups. Flow cytometry revealed higher proportions of CD4+ Tm cells [(55.3 ± 4.8)% vs. (38.8 ± 6.1)%; t = -4.259, P < 0.05] and CD4+ tissue-resident Tm (Trm) cells [(57.7 ± 3.7)% vs. (34.1 ± 11.2)%; t = -3.990, P < 0.05] in mouse lymph nodes in the infection group than in the control group 4 weeks post-infection, and higher proportions of CD4+ Tm cells [(34.6 ± 3.2)% vs. (23.3 ± 7.5)%; t = -2.764, P < 0.05] and CD4+ Trm cells [(44.0 ± 1.9)% vs. (31.2 ± 1.5)%; t = -4.039, P < 0.05] in mouse lymph nodes in the infection group than in the control group 24 weeks post-infection. The proportions of CD8+ Tm cells were higher in the infection group than in the control group 4 weeks [(56.8 ± 2.7)% vs. (43.9 ± 5.2)%; t = -4.416, P < 0.01] and 12 weeks post-infection [(25.4 ± 2.7)% vs. (12.0 ± 2.6)%; t = -2.552, P < 0.05], while the proportions of tumor necrosis factor (TNF)-α+ CD4+ T cells [(15.7 ± 5.0)% vs. (49.4 ± 6.4)%; t = 7.150, P < 0.01], TNF-α+CD8+ T cells [(20.7 ± 5.5)% vs. (57.5 ± 8.4)%; t = -6.694, P < 0.01], and TNF-α+ CD8+ Tm cells [7.0% (1.0%) vs. 31.0% (11.0%); Z = -2.236, P < 0.05] were lower in the infection group than in the control group 24 weeks post-infection. Conclusions Tm cells levels are consistently increased in lymph nodes of mice at different stages of E. multilocularis infection, with Trm cells as the predominantly elevated subset. The impaired capacity of CD8+ Tm cells to secrete the effector molecule TNF-α in mouse lymph nodes at the late-stage infection may facilitate chronic parasitism of E. multilocularis.
8.Real-world efficacy and safety of azvudine in hospitalized older patients with COVID-19 during the omicron wave in China: A retrospective cohort study.
Yuanchao ZHU ; Fei ZHAO ; Yubing ZHU ; Xingang LI ; Deshi DONG ; Bolin ZHU ; Jianchun LI ; Xin HU ; Zinan ZHAO ; Wenfeng XU ; Yang JV ; Dandan WANG ; Yingming ZHENG ; Yiwen DONG ; Lu LI ; Shilei YANG ; Zhiyuan TENG ; Ling LU ; Jingwei ZHU ; Linzhe DU ; Yunxin LIU ; Lechuan JIA ; Qiujv ZHANG ; Hui MA ; Ana ZHAO ; Hongliu JIANG ; Xin XU ; Jinli WANG ; Xuping QIAN ; Wei ZHANG ; Tingting ZHENG ; Chunxia YANG ; Xuguang CHEN ; Kun LIU ; Huanhuan JIANG ; Dongxiang QU ; Jia SONG ; Hua CHENG ; Wenfang SUN ; Hanqiu ZHAN ; Xiao LI ; Yafeng WANG ; Aixia WANG ; Li LIU ; Lihua YANG ; Nan ZHANG ; Shumin CHEN ; Jingjing MA ; Wei LIU ; Xiaoxiang DU ; Meiqin ZHENG ; Liyan WAN ; Guangqing DU ; Hangmei LIU ; Pengfei JIN
Acta Pharmaceutica Sinica B 2025;15(1):123-132
Debates persist regarding the efficacy and safety of azvudine, particularly its real-world outcomes. This study involved patients aged ≥60 years who were admitted to 25 hospitals in mainland China with confirmed SARS-CoV-2 infection between December 1, 2022, and February 28, 2023. Efficacy outcomes were all-cause mortality during hospitalization, the proportion of patients discharged with recovery, time to nucleic acid-negative conversion (T NANC), time to symptom improvement (T SI), and time of hospital stay (T HS). Safety was also assessed. Among the 5884 participants identified, 1999 received azvudine, and 1999 matched controls were included after exclusion and propensity score matching. Azvudine recipients exhibited lower all-cause mortality compared with controls in the overall population (13.3% vs. 17.1%, RR, 0.78; 95% CI, 0.67-0.90; P = 0.001) and in the severe subgroup (25.7% vs. 33.7%; RR, 0.76; 95% CI, 0.66-0.88; P < 0.001). A higher proportion of patients discharged with recovery, and a shorter T NANC were associated with azvudine recipients, especially in the severe subgroup. The incidence of adverse events in azvudine recipients was comparable to that in the control group (2.3% vs. 1.7%, P = 0.170). In conclusion, azvudine showed efficacy and safety in older patients hospitalized with COVID-19 during the SARS-CoV-2 omicron wave in China.
9.A Novel Model of Traumatic Optic Neuropathy Under Direct Vision Through the Anterior Orbital Approach in Non-human Primates.
Zhi-Qiang XIAO ; Xiu HAN ; Xin REN ; Zeng-Qiang WANG ; Si-Qi CHEN ; Qiao-Feng ZHU ; Hai-Yang CHENG ; Yin-Tian LI ; Dan LIANG ; Xuan-Wei LIANG ; Ying XU ; Hui YANG
Neuroscience Bulletin 2025;41(5):911-916
10.Construction and validation of a prognostic prediction model for pediatric sepsis based on the Phoenix sepsis score.
Yongtian LUO ; Hui SUN ; Zhigui JIANG ; Zhen YANG ; Chengxi LU ; Lufei RAO ; Tingting PAN ; Yuxin RAO ; Xiao LI ; Honglan YANG
Chinese Critical Care Medicine 2025;37(9):856-860
OBJECTIVE:
To construct and validate a prognostic prediction model for children with sepsis using the Phoenix sepsis score (PSS).
METHODS:
A retrospective case series study was conducted to collect clinical data of children with sepsis admitted to the pediatric intensive care unit (PICU) of the Affiliated Hospital of Guizhou Medical University from January 2022 to April 2024. The data included general information, the worst values of laboratory indicators within the first 24 hours of PICU admission, PSS score, pediatric critical illness score (PCIS), and the survival status of the children within 30 days of admission. The statistically significant indicators in univariate Logistic regression analysis were included in multivariate Logistic regression analysis to screen the risk factors affecting the prognosis of children with sepsis and construct a nomogram model. The receiver operator characteristic curve (ROC curve) was drawn to evaluate the predictive performance of the model. The Bootstrap method was used to perform 1 000 repeated sampling internal verification and draw the calibration curve of the model.
RESULTS:
A total of 199 children with sepsis were included, of which 32 died and 167 survived 30 days after admission. In the univariate Logistic regression analysis, shock, white blood cell count (WBC), international normalized ratio (INR), lactic acid (Lac), PSS score, and PCIS score were identified as statistically significant predictors. These variables were then included in the multivariate Logistic regression analysis, which demonstrated that shock [odds ratio (OR) = 4.258, 95% confidence interval (95%CI) was 1.049-17.288], WBC (OR = 1.124, 95%CI was 1.052-1.210), and PSS score (OR = 1.977, 95%CI was 1.298-3.012) were independent risk factors for mortality in pediatric patients with sepsis (all P < 0.05). A nomogram model was constructed based on these three risk factors, with the model equation as follows: -4.809+1.449×shock+0.682×PSS score+0.117×WBC. The calibration curve results showed that the model's predictions were highly consistent with the actual observations. The ROC curve showed that when the Youden index of the prediction model was 0.792, the sensitivity and specificity were 90.6% and 88.6%, respectively, and the area under the curve (AUC) was 0.957 (95%CI was 0.930-0.984), which was higher than the AUC of shock, WBC, and PSS score alone (0.808, 0.667, 0.908, respectively).
CONCLUSIONS
Shock, WBC, and PSS score have demonstrated certain predictive value for mortality in children with sepsis. The nomogram model based on the above indicators has important clinical significance for evaluating the prognosis and guiding treatment of children with sepsis.
Humans
;
Sepsis/diagnosis*
;
Prognosis
;
Retrospective Studies
;
Logistic Models
;
Intensive Care Units, Pediatric
;
Nomograms
;
Child
;
ROC Curve
;
Risk Factors
;
Male
;
Female
;
Child, Preschool
;
Infant

Result Analysis
Print
Save
E-mail