1.Neuroprotective effect and mechanism of eleutheroside B on Parkinson’s disease model mice by regulating the IKKβ/NF-κB signaling pathway
Xiaoli WANG ; Hua RONG ; Siwen PAN ; Chunlei YU ; Tianjiao XU ; Yu SUN ; Huan CONG ; Yu PANG ; Gang CHEN ; Xiaoming LI
China Pharmacy 2026;37(8):998-1002
OBJECTIVE To investigate the neuroprotective effect and mechanism of eleutheroside B (ELB) on Parkinson’s disease (PD) model mice by regulating the IκB kinase β (IKKβ)/nuclear factor-κB (NF-κB) signaling pathway. METHODS Fifty mice were randomly divided into normal control group, model group, positive control group (selegiline hydrochloride, 10 mg/kg), and ELB low-dose and high-dose groups (80, 160 mg/kg), with 10 mice in each group. Each group was given relevant medicine or normal saline intragastrically for 14 consecutive days. Starting from the 10th day of administration, the model group and all administration groups were intraperitoneally injected with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) 30 mg/kg, for five consecutive days to establish the chronic PD model. After the last administration for 24 h, six mice were randomly selected from each group to test their behavioral abilities; detect the levels of interleukin-1β (IL-1β), IL-10, tumor necrosis factor-α (TNF-α) in brain tissue and their mRNA expressions were measured, and positive expression of tyrosine hydroxylase (TH), protein expressions of TH, α -synuclein ( α -syn), ionized calcium-binding adaptor molecule 1 (Iba-1), as well as phosphorylation levels of IKKβ and NF-κB p65 proteins in the brain tissue were detected. The ultrastructure of neurons in substantia nigra was observed. RESULTS Compared with the model group, rotarod endurance time and climbing score of each administration group (except for the ELB low-dose group) were increased significantly ( P <0.05), while the levels and mRNA expressions of IL-1β, TNF-α, α -syn, and Iba-1, as well as phosphorylation levels of IKKβ and NF-κB p65 proteins in brain tissue were decreased significantly (except for TNF-α in the ELB low-dose group). Conversely, the level and mRNA expression of IL-10 (except for the ELB low-dose group), TH positive expression and protein expressions were significantly increased ( P <0.05). Typical neurodegenerative pathological changes, such as neuronal karyopyknosis, mitochondrial swelling and vacuolization, and endoplasmic reticulum dilation, all showed varying degrees of improvement. CONCLUSIONS ELB may exert neuroprotective effects by inhibiting the activation of the IKKβ/NF-κB signaling pathway, alleviating inflammatory responses, reducing abnormal α -syn aggregation and neuronal loss, and further improving motor dysfunction in PD mice.
2.Traditional Chinese Medicine Prevention and Treatment of Ischemic Stroke by Intervening in Brain Microvascular Endothelial Cells: A Review
Wenxiu QIN ; Gang WEI ; Qingjie KONG ; Huiying SUN ; Junfeng XU ; Ying GAO ; Jian YANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):336-346
The blood-brain barrier (BBB) is a physical and biochemical barrier that precisely regulates brain homeostasis and plays a central role in controlling the transport of endogenous and exogenous drugs and related metabolites across the blood-brain interface. These functions of the BBB are mediated by its major components, including brain microvascular endothelial cells (BMECs), tight junction protein complexes, and influx and efflux transporter proteins. One of the pathological features of ischemic stroke (IS) is BBB disruption, which plays an important role in the development of post-stroke brain injury and subsequent neurological dysfunction. Therefore, given the increasing incidence of IS, there is an urgent need to develop new therapeutic strategies to prevent BBB dysfunction and thereby protect injured brain tissue after IS. This study describes the pathological mechanisms by which BMEC injury after IS leads to BBB dysfunction and elucidates the association between BMECs and IS, including the regulation of apoptosis, autophagy, inflammatory responses, oxidative stress, neurotoxic effects, and cerebral edema. In addition, this article summarizes Chinese herbal medicines that may prevent and treat IS by targeting BMECs. These include monomeric compounds and single herbs such as flavonoids, glycosides, phenols, phthalides, terpenoids, and Styrax. Traditional Chinese medicine (TCM) compound formulas and preparations include oral formulations such as Buyang Huanwu decoction, Sailuotong, Naoxintong capsules, Dandeng Tongnao capsules, and Shexiang Tongxin dropping pills, as well as injectable preparations such as Tongluo Jiunao injection, Xingnaojing injection, Danshen polyphenolic acid for injection, Yiqi Fumai injection, and Shuxuetong injection. This study aims to explore the protective effects of TCM against IS through targeted regulation of BMEC function, providing new insights into the mechanisms of IS and endovascular therapeutic strategies.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
9.Multidisciplinary expert consensus on weight management for overweight and obese children and adolescents based on healthy lifestyle
HONG Ping, MA Yuguo, TAO Fangbiao, XU Yajun, ZHANG Qian, HU Liang, WEI Gaoxia, YANG Yuexin, QIAN Junwei, HOU Xiao, ZHANG Yimin, SUN Tingting, XI Bo, DONG Xiaosheng, MA Jun, SONG Yi, WANG Haijun, HE Gang, CHEN Runsen, LIU Jingmin, HUANG Zhijian, HU Guopeng, QIAN Jinghua, BAO Ke, LI Xuemei, ZHU Dan, FENG Junpeng, SHA Mo, Chinese Association for Student Nutrition & ; Health Promotion, Key Laboratory of Sports and Physical Fitness of the Ministry of Education,〖JZ〗 Engineering Research Center of Ministry of Education for Key Core Technical Integration System and Equipment,〖JZ〗 Key Laboratory of Exercise Rehabilitation Science of the Ministry of Education
Chinese Journal of School Health 2025;46(12):1673-1680
Abstract
In recent years, the prevalence of overweight and obesity among children and adolescents has risen rapidly, posing a serious threat to their physical and mental health. To provide scientific, systematic, and standardized weight management guidance for overweight and obese children and adolescents, the study focuses on the core concept of healthy lifestyle intervention, integrates multidisciplinary expert opinions and research findings,and proposes a comprehensive multidisciplinary intervention framework covering scientific exercise intervention, precise nutrition and diet, optimized sleep management, and standardized psychological support. It calls for the establishment of a multi agent collaborative management mechanism led by the government, implemented by families, fostered by schools, initiated by individuals, optimized by communities, reinforced by healthcare, and coordinated by multiple stakeholders. Emphasizing a child and adolescent centered approach, the consensus advocates for comprehensive, multi level, and personalized guidance strategies to promote the internalization and maintenance of a healthy lifestyle. It serves as a reference and provides recommendations for the effective prevention and control of overweight and obesity, and enhancing the health level of children and adolescents.
10.Evaluation of clinical effectiveness of retrograde recanalization of occluded radial artery via distal transradial approach
Xiao-fei XIE ; Sheng-xin ZUO ; Jin-peng XU ; Xiao-liang HAN ; Gang-cheng SUN ; Liang LI
Chinese Journal of Interventional Cardiology 2025;33(3):135-140
Objective Radial artery occlusion(RAO)is one of the common complications following coronary intervention via the traditional radial artery approach.This study aims to evaluate the clinical effectiveness of retrograde recanalization of occluded radial arteries through the distal transradial approach(dTRA)approach.Methods A total of 35 patients with RAO admitted to the cardiovascular department of the Anhui Chest hospital between December 2022 and April 2024,who were scheduled to undergo coronary intervention and had attempted recanalization of RAO via dTRA approach were selected.The primary result was the success rate of recanalizing RAO via dTRA.The secondary results included factors influencing the failure of recanalization via dTRA,postoperative puncture complications,and the patency rate at the 3-month follow-up.Results This study divided the patients into a successful group(29 cases,82.9%)and a failed group(6 cases,17.1%)based on whether the distal radial artery was successfully opened and occluded.The proportion of smoking(100.00%vs.17.24%,P=0.040),history of diabetes(100.00%vs.10.34%,P=0.025),and chronic total occlusion of coronary artery(83.33%vs.17.24%,P=0.030)in the failure group were higher than those in the success group,and the difference was statistically significant.The application rate of balloon tracking assisted technology in the failed group(16.67%vs.58.62%,P=0.045),and the diameter of the radial artery at 3 days after surgery[(1.63±0.13)mm vs.(2.13±0.32)mm,P=0.021]and the peak radial artery blood flow velocity at 3 days postoperatively[(0.10±0.78)m/s vs.(0.50±0.13)m/s,P<0.001]were all lower in the successful group,and the differences were statistically significant.Logistic regression analysis 3 days after surgery showed that chronic complete occlusion of the coronary artery was an independent risk factor for surgical opening failure(OR 0.042,95%CI 0.004-0.438,P=0.008).After 3 months of follow-up,the patency rate of the successful group was 55.2%.Conclusions Retrograde recanalization of RAO via dTRA is safe and feasible,but its long-term patency rate is not high.


Result Analysis
Print
Save
E-mail