1.Epidemiological characteristics and trends of other infectious diarrhea among children during 2014-2020
Chinese Journal of School Health 2025;46(7):922-925
Objective:
To analyze the epidemiological characteristics and trends of other infectious diarrhea among children under 18 years old in Guangzhou City from 2014 to 2020, and to explore the correlation between climatic factors and the incidence of the disease, so as to provide reference for the early prevention of infectious diseases.
Methods:
The data of cases of other infectious diarrhea and meteorological data of children under 18 years old in Guangzhou City from 2014 to 2020 were collected through the Chinese Infectious Disease Reporting System and the Guangzhou Meteorological Bureau. The correlation between meteorological factors and the incidence of other infectious diarrhea was analyzed using negative binomial regression.
Results:
A total of 104 566 cases of other infectious diarrhea among children under 18 years old were reported in Guangzhou City from 2014 to 2020, with a male to female ratio of 1.48∶1. The incidence rate was the highest in 2017 (980.83 per 100 000) and the lowest in 2020 (388.22 per 100 000). The peak of incidence occurred from October to March of the following year. Children under 5 years old accounted for 87.95% of all cases. The number of cases of other infectious diarrhea was negatively correlated with the temperature of the previous 6 days ( IRR = -0.07 ), and positively correlated with the temperature difference on the day of onset ( IRR =0.02) (both P <0.05). It was also positively correlated with the wind speed of the previous 7 days ( IRR=0.07, P <0.05), but there was no statistically significant correlation with the relative humidity on the day of onset ( IRR=-0.00, P >0.05).
Conclusions
Low temperature, large temperature difference, and high wind speed can increase the risk of other infectious diarrhea. It is necessary to strengthen the prediction and early warning in conjunction with meteorological changes, and warn kindergartens and schools to enhance preventive measures against the clustering of other infectious diarrhea cases.
2.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
3.A strategy to reduce unnecessary prostate biopsies in patients with tPSA >10 ng ml -1 and PI-RADS 1-3.
Qi-Fei DONG ; Yi-Xun LIU ; Yu-Han CHEN ; Yi-Fan MA ; Tao ZHOU ; Xue-Feng FAN ; Xiang YU ; Chang-Ming WANG ; Jun XIAO
Asian Journal of Andrology 2025;27(4):531-536
We propose a strategy to reduce unnecessary prostate biopsies in Chinese patients with total prostate-specific antigen (tPSA) >10 ng ml -1 and Prostate Imaging Reporting and Data System (PI-RADS) scores between 1 and 3. Clinical data derived from 517 patients of The First Affiliated Hospital of USTC (Hefei, China) from January 2020 to December 2023 who met the screening criteria for the study were retrospectively collected. Independent predictors were identified via univariate and multivariate logistic regression analysis. The diagnostic capacity of clinical variables was evaluated using the receiver operating characteristic (ROC) curves and area under the curve (AUC). A prostate biopsy strategy was developed via risk stratification. Of the 517 patients, 17/348 (4.9%) with PI-RADS 1-2 were diagnosed with clinically significant prostate cancer (csPCa), and 27/169 (16.0%) patients with PI-RADS 3 were diagnosed with csPCa. The appropriate prostate-specific antigen density (PSAD) cut-off values were 0.45 ng ml -2 for PI-RADS 1-2 patients and 0.3 ng ml -2 for PI-RADS 3 patients. The appropriate prostate volume (PV) cut-off values were 40 ml for PI-RADS 1-2 patients and 50 ml for PI-RADS 3 patients. The prostate biopsy strategy based on PSAD and PV developed in this study can reduce unnecessary prostate biopsies in patients with tPSA >10 ng ml -1 and PI-RADS 1-3. In the study, 66.5% (344/517) patients did not need to undergo prostate biopsy, at the expense of missing only 1.7% (6/344) patients with csPCa.
Humans
;
Male
;
Prostatic Neoplasms/diagnostic imaging*
;
Prostate-Specific Antigen/blood*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Prostate/diagnostic imaging*
;
Unnecessary Procedures/statistics & numerical data*
;
Biopsy/statistics & numerical data*
;
China
;
ROC Curve
4.Functional and oncologic outcomes of partial nephrectomy for cystic renal cell carci-noma:A single-center retrospective study
Fan SHU ; Yichang HAO ; Zhanyi ZHANG ; Shaohui DENG ; Hongxian ZHANG ; Lei LIU ; Guoliang WANG ; Xiao-Jun TIAN ; Lei ZHAO ; Lulin MA ; Shudong ZHANG
Journal of Peking University(Health Sciences) 2024;56(4):667-672
Objective:To investigate the postoperative renal function and oncologic outcomes of cystic renal cell carcinoma with partial nephrectomy,and to compared the single-center data on surgical out-comes with the Surveillance,Epidemiology,and End Results(SEER)database.Methods:This was a retrospective study that included the patients with cystic renal cell carcinoma who underwent partial ne-phrectomy in the Department of Urology,Peking University Third Hospital(PUTH)from 2010 to 2023.The clinical data and depicting baseline characteristics were collected.Renal dynamic imaging and the Chinese Coefficients for Chronic Kidney Disease Epidemiology Collaboration(C-CKD-EPI)formulae were used to calculate the estimated glomerular filtration rate(eGFR).The renal function curves over time were then plotted,and the patients were followed-up to record their survival status.Cases of cystic renal cell carcinoma in the SEER database between 2000 and 2020 were included,propensity score matching(PSM)was performed to balance the differences between SEER cohort and PUTH cohort,and the cancer-specific survival(CSS)curves for both groups were plotted and statistical differences were calcu-lated by the Kaplan-Meier method.Results:A total of 38 and 385 patients were included in the PUTH cohort and SEER cohort,respectively,and 31 and 72 patients were screened in each cohort after PSM.Of the baseline characteristics,only tumor size(P=0.042)was found to differ statistically between the two groups.There was no statistically significant difference between the two cohorts in terms of CSS after PSM(P=0.556).The median follow-up time in the SEER cohort was 112.5(65,152)months and a 10-year survival rate of 97.2%,while the PUTH cohort had a median follow-up of 57.0(20,1 172)months and a 10-year survival rate of 100.0%.There was no statistically significant difference between eGFR determined by preoperative renal dynamic imaging and the results of the C-CKD-EPI formulae based on creatinine estimation(P=0.073).There was a statistically significant difference in eGFR among the preoperative,short-term postoperative,and long-term postoperative(P<0.001),which was characterized by the presence of a decline in renal function in the short-term postoperative period and the recovery of renal function in the long-term period.Conclusion:Partial nephrectomy for cystic renal cell carcinoma is safe and feasible with favorable renal function and oncologic outcomes.
5.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.
6.PET/MR attenuation correction method based on transmission scan
Shengnan FAN ; Xingzhao GUO ; Weidong MA ; Jun DENG ; Lei DENG ; Xiaoping LIU
Chinese Journal of Radiological Health 2024;33(5):499-504
Objective To propose a method for correcting the attenuation of positron emission tomography (PET) data in PET/magnetic resonance (MR) based on transmission scan, and to improve image quality, diagnostic accuracy, and lesion location accuracy. Methods In this study, the head phantom in the national standard GB/T 18988.1—2013 was used as the experimental model. The head phantom contained three 50 mm diameter cylindrical inserts filled with air, water, and solid teflon. The attenuation correction coefficients were calculated and analyzed based on transmission scan. Results With slice = 33 and theta = 0, the attenuation correction coefficient was the largest (about 7.5) when the coincidence line passed through the axis of the phantom. The spatial distribution of the attenuation correction coefficients clearly showed the positions of air insert and teflon insert, indicating that the attenuation correction coefficients calculated from transmission scan data were accurate. In the clinical verification experiment, the attenuation correction method based on transmission scan significantly improved the image quality and showed efficient attenuation correction. Conclusion This paper studied the attenuation correction method for PET data in PET/MR based on transmission scan. This method can improve the image quality. In the future work, the attenuation correction method of PET/MR will be further studied and optimized to facilitate clinical applications.
7.PET/MR attenuation correction method based on transmission scan
Shengnan FAN ; Xingzhao GUO ; Weidong MA ; Jun DENG ; Lei DENG ; Xiaoping LIU
Chinese Journal of Radiological Health 2024;33(5):499-504
Objective To propose a method for correcting the attenuation of positron emission tomography (PET) data in PET/magnetic resonance (MR) based on transmission scan, and to improve image quality, diagnostic accuracy, and lesion location accuracy. Methods In this study, the head phantom in the national standard GB/T 18988.1—2013 was used as the experimental model. The head phantom contained three 50 mm diameter cylindrical inserts filled with air, water, and solid teflon. The attenuation correction coefficients were calculated and analyzed based on transmission scan. Results With slice = 33 and theta = 0, the attenuation correction coefficient was the largest (about 7.5) when the coincidence line passed through the axis of the phantom. The spatial distribution of the attenuation correction coefficients clearly showed the positions of air insert and teflon insert, indicating that the attenuation correction coefficients calculated from transmission scan data were accurate. In the clinical verification experiment, the attenuation correction method based on transmission scan significantly improved the image quality and showed efficient attenuation correction. Conclusion This paper studied the attenuation correction method for PET data in PET/MR based on transmission scan. This method can improve the image quality. In the future work, the attenuation correction method of PET/MR will be further studied and optimized to facilitate clinical applications.
8.Atrial septal puncture in swine guided by X-ray fluoroscopy
Gai-Gai MA ; Feng-Xu FAN ; Jun CHEN ; Bao-Kun WANG ; Ming-Yang QIAO ; Kang-An CHENG
Chinese Journal of Interventional Cardiology 2024;32(5):257-260
Objective To explore the standardized process and method of atrial septum puncture(ASP)in swine guided by X-ray fluoroscopy and make ASP more safe and effective.Methods ASP was performed in 48 Pudong swines guided by X-ray fluoroscopy.Three protocols for precise location of atrial septal puncture points were recommended.(1)Site of atrial septal puncture point in cranial-caudal direction was determined under posterior-anterior projection,which was confined to the cranial side of the coronary sinus(CS)orifice at a distance of 1 cone body height along the midline of spine.(2)With 10° intervals,the fluoroscopy of the CS catheter was completed according to the right anterior oblique 10°~60° and the left anterior oblique 10°~60°,and the connection line of the CS 5-6 and 7-8 electrodes was perpendicular to the oval fossa,so as to confirm the perspective angle of the CS 5-6 and 7-8 electrodes in the same straight line.(3)The arch feature of puncture needle and distal part of sheath turned into a straight line under the perspective angle,of which the CS 5-6 and 7-8 electrodes were in the same straight line.Results ASP was successfully performed in 48 Pudong swines without any complications.Echocardiography showed left to right shunt through atrial septum after ASP.The average time of ASP was(25.7±11.5)minutes,the average X-ray exposure time is(14.0±3.4)min and the average radiation dose was(47.6±20.2)Gmy.Conclusions Using the coronal sinus electrode as a reference,atrial septal puncture in swine guided by X-ray fluoroscopy was safe and reliable.
9.Investigation on prevalence of Klebsiella pneumoniae in calves with pneumonia and analysis of some of its biological characteristics in some areas of Xinjiang
Yilin WANG ; Yan WANG ; Wanpeng MA ; Ling ZHANG ; Mingqiang GUO ; Xiaohui FAN ; Jun XIA ; Zhanqiang SU
Chinese Journal of Veterinary Science 2024;44(9):1906-1913
Klebsiella pneumoniae(KPn),as a conditioned pathogen that causes calf pneumonia,has caused serious harm to cattle industry,but the harm of Klebsiella pneumoniae to calves in Xin-jiang region is still unclear.In this study,to investigate the prevalence of KPn,its harm and some biological characteristics of pneumonia calves in Xinjiang,nasal swabs of pneumonia calves in some areas were collected aseptically,KPn isolation and identification were performed by routine meth-od,and 16S rDNA sequence evolutionary tree analysis was performed.The drug resistance was de-tected by K-B method,and a strain carrying multiple virulence was selected for mice median lethal dose test.The serotype,virulence gene and drug resistance gene of the strain were detected by PCR.The results showed that the detection rate of Klebsiella pneumoniae in nasal swabs of 218 pneumonia calves from Aksu,Changji and Yili regions of Xinjiang was as follows:14.68%(32/218),including 28.33%(17/60)in Aksu Prefecture,24.00%(6/25)in Changji Prefecture and 6.77%(9/133)in Yili Prefecture,they were divided into two serotypes,namely K1(7/32)and K5(5/32).A total of 13 KPn virulence genes were detected,mainly mrkD,ureA,wabG,uge and en-tB.LD50 was 2.38X 107cfu/mL.Drug susceptibility test and drug resistance gene detection showed that the isolated strain showed multiple drug resistance,and the resistance genes mainly carried blasHv and floR.16S rDNA sequence evolutionary tree results showed that the isolated strain had high homology with the isolates from Italy,Beijing and Shanghai of China.The detection rate of KPn in nasal swabs of pneumonia calves in Xinjiang region is high.The dominant serotypes are K1 and K5.The isolates carry a variety of virulence genes and have strong virulence.All of them are KPn strains producing ESBLs,suggesting that Klebsiella pneumoniae in Xinjiang region of China have a certain potential harm to calves.
10.Development of portable medical oxygen purity analyzer
Lin-Xia LI ; Jun-Bo GAO ; Rong FAN ; Ting WU ; Ya-Jiao XU ; Yan-Qi LIU ; Jin MA ; Yun-Ying WANG
Chinese Medical Equipment Journal 2024;45(3):36-40
Objective To develop a portable medical oxygen purity analyzer capable of real-time detection of multi-compo-nent gases in medical oxygen or aviation oxygen to ensure the safety of oxygen consumption.Methods The portable medical oxygen purity analyzer with STM3F103RC as the main controller involved in a management module,an oxygen detection module,a carbon monoxide/chlorine detection module,a flow/carbon dioxide detection module and a dew point detection module as its hardware components,which had its human-machine interface programmed with DGUS supervision,control and data acquisition(SCADA)software and system program developed with C language under Keil MDK environment.The performance verification of the analyzer developed was carried out in terms of oxygen detection error and stability and errors for measuring carbon monoxide,chlorine and carbon dioxide.Results The analyzer showed high precision when used to detect oxygen with high volume fraction,with long-term stability and the absolute error restrained within±0.1%;the erros for measuring carbon monoxide,chlorine and carbon dioxide were all limited within±5%FS to meet the desired requirements.Condusion The portable medical oxygen purity analyzer developed with high precision,stability and portability can be used for detection of medical oxygen and aviation oxygen.[Chinese Medical Equipment Journal,2024,45(3):36-40]


Result Analysis
Print
Save
E-mail