1.Quality Evaluation and Analysis of Key Problems in Rukuaixiao Preparations
Rong CHEN ; Chao ZHANG ; Shuisheng ZHONG ; Wei CHEN ; Enyun TU ; Yaqiong WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):146-155
ObjectiveBased on multi-index and multi-method detection, the quality of Rukuaixiao preparations was systematically evaluated from the perspective of characteristic components, and the existing problems were analyzed. MethodsLiquid chromatography-mass spectrometry(LC-MS) for the determination of 16 characteristic components was established to evaluate the quality of 129 batches of Rukuaixiao preparations. High performance liquid chromatography(HPLC) was established to determine the contents of salvianolic acids and tanshinones, investigate the rationality of quality control index of Salviae Miltiorrhizae Radix et Rhizoma in the standard for Rukuaixiao preparations in the 2020 edition of Pharmacopoeia of the People's Republic of China(hereinafter referred to as Chinese Pharmacopoeia) (volume Ⅰ), and trace the causes of significant difference among different batches. The processing and different extraction methods of Vaccariae Semen were tested, analyzing the impact of formulation changes across different editions of Chinese Pharmacopoeia. The LC-MS was established for determining the changes in the ratio of toosendanin and isotoosendanin after water extraction of Toosendan Fructus. The contents of active components in different parts of Gleditsiae Spina were determined to identify the reason of the low contents of characteristic components in some enterprises. ResultsBased on the comprehensive analysis of the samples from different dosage forms, the contents of characteristic components of Vaccariae Semen and Gleditsiae Spina in tablets from manufacturer B and granules from manufacturer D were significantly higher than those in tablets from manufacturer A, and tablets and capsules from manufacturer C. The contents of tanshinones in some batches of products from manufacturer A were abnormally high, potentially linked to the use of 70% ethanol reflux during extraction of Salviae Miltiorrhizae Radix et Rhizoma. All samples from manufacturer C exhibited abnormally high proportions of salvianic acid A and 3,4-dihydroxybenzaldehyde(salvianolic acid degradation products) to the total seven phenolic acids, indicating a risk of blindly pursuing tanshinol content and neglecting more effective components. The extraction rate of the characteristic components from Vaccariae Semen by decocting with water was obviously higher than that by reflux extraction with 70% ethanol. However, using the stir-fried Vaccariae Semen could reduce the loss of ingredients. The content ratio of toosendanin and isotoosendanin decreased from the crude herb to the prepared medicine when Toosendan Fructus was prepared by water decoction. The reason for the low component content of Gleditsiae Spina may be attributed to manufacturers using excessive non-medicinal parts in their formulations. ConclusionIt is suggested that enterprises should ensure the quality of raw material inputs, especially those without quality-control items in the standard, reduce the use of non-medicinal parts, and prohibit arbitrary alterations to manufacturing methods or processes. It is also recommended that Vaccariae Semen in Rukuaixiao capsules and granules should be changed to the stir-fried processed products. Isotoosendanin should be taken into consideration in the drug supervision when Toosendan Fructus is prepared into medicine by water decoction. Salvianolic acid B should be set as a quality control index for Salviae Miltiorrhizae Radix et Rhizoma when revising the pharmacopoeia standard of Rukuaixiao preparations.
2.Quality Evaluation and Analysis of Key Problems in Rukuaixiao Preparations
Rong CHEN ; Chao ZHANG ; Shuisheng ZHONG ; Wei CHEN ; Enyun TU ; Yaqiong WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(21):146-155
ObjectiveBased on multi-index and multi-method detection, the quality of Rukuaixiao preparations was systematically evaluated from the perspective of characteristic components, and the existing problems were analyzed. MethodsLiquid chromatography-mass spectrometry(LC-MS) for the determination of 16 characteristic components was established to evaluate the quality of 129 batches of Rukuaixiao preparations. High performance liquid chromatography(HPLC) was established to determine the contents of salvianolic acids and tanshinones, investigate the rationality of quality control index of Salviae Miltiorrhizae Radix et Rhizoma in the standard for Rukuaixiao preparations in the 2020 edition of Pharmacopoeia of the People's Republic of China(hereinafter referred to as Chinese Pharmacopoeia) (volume Ⅰ), and trace the causes of significant difference among different batches. The processing and different extraction methods of Vaccariae Semen were tested, analyzing the impact of formulation changes across different editions of Chinese Pharmacopoeia. The LC-MS was established for determining the changes in the ratio of toosendanin and isotoosendanin after water extraction of Toosendan Fructus. The contents of active components in different parts of Gleditsiae Spina were determined to identify the reason of the low contents of characteristic components in some enterprises. ResultsBased on the comprehensive analysis of the samples from different dosage forms, the contents of characteristic components of Vaccariae Semen and Gleditsiae Spina in tablets from manufacturer B and granules from manufacturer D were significantly higher than those in tablets from manufacturer A, and tablets and capsules from manufacturer C. The contents of tanshinones in some batches of products from manufacturer A were abnormally high, potentially linked to the use of 70% ethanol reflux during extraction of Salviae Miltiorrhizae Radix et Rhizoma. All samples from manufacturer C exhibited abnormally high proportions of salvianic acid A and 3,4-dihydroxybenzaldehyde(salvianolic acid degradation products) to the total seven phenolic acids, indicating a risk of blindly pursuing tanshinol content and neglecting more effective components. The extraction rate of the characteristic components from Vaccariae Semen by decocting with water was obviously higher than that by reflux extraction with 70% ethanol. However, using the stir-fried Vaccariae Semen could reduce the loss of ingredients. The content ratio of toosendanin and isotoosendanin decreased from the crude herb to the prepared medicine when Toosendan Fructus was prepared by water decoction. The reason for the low component content of Gleditsiae Spina may be attributed to manufacturers using excessive non-medicinal parts in their formulations. ConclusionIt is suggested that enterprises should ensure the quality of raw material inputs, especially those without quality-control items in the standard, reduce the use of non-medicinal parts, and prohibit arbitrary alterations to manufacturing methods or processes. It is also recommended that Vaccariae Semen in Rukuaixiao capsules and granules should be changed to the stir-fried processed products. Isotoosendanin should be taken into consideration in the drug supervision when Toosendan Fructus is prepared into medicine by water decoction. Salvianolic acid B should be set as a quality control index for Salviae Miltiorrhizae Radix et Rhizoma when revising the pharmacopoeia standard of Rukuaixiao preparations.
3.Safety and effectiveness of lecanemab in Chinese patients with early Alzheimer's disease: Evidence from a multidimensional real-world study.
Wenyan KANG ; Chao GAO ; Xiaoyan LI ; Xiaoxue WANG ; Huizhu ZHONG ; Qiao WEI ; Yonghua TANG ; Peijian HUANG ; Ruinan SHEN ; Lingyun CHEN ; Jing ZHANG ; Rong FANG ; Wei WEI ; Fengjuan ZHANG ; Gaiyan ZHOU ; Weihong YUAN ; Xi CHEN ; Zhao YANG ; Ying WU ; Wenli XU ; Shuo ZHU ; Liwen ZHANG ; Naying HE ; Weihuan FANG ; Miao ZHANG ; Yu ZHANG ; Huijun JU ; Yaya BAI ; Jun LIU
Chinese Medical Journal 2025;138(22):2907-2916
INTRODUCTION:
Lecanemab has shown promise in treating early Alzheimer's disease (AD), but its safety and efficacy in Chinese populations remain unexplored. This study aimed to evaluate the safety and 6-month clinical outcomes of lecanemab in Chinese patients with mild cognitive impairment (MCI) or mild AD.
METHODS:
In this single-arm, real-world study, participants with MCI due to AD or mild AD received biweekly intravenous lecanemab (10 mg/kg). The study was conducted at Hainan Branch, Ruijin Hospital Shanghai Jiao Tong University School of Medicine. Patient enrollment and baseline assessments commenced in November 2023. Safety assessments included monitoring for amyloid-related imaging abnormalities (ARIA) and other adverse events. Clinical and biomarker changes from baseline to 6 months were evaluated using cognitive scales (mini-mental state examination [MMSE], montreal cognitive assessment [MoCA], clinical dementia rating-sum of boxes [CDR-SB]), plasma biomarker analysis, and advanced neuroimaging.
RESULTS:
A total of 64 patients were enrolled in this ongoing real-world study. Safety analysis revealed predominantly mild adverse events, with infusion-related reactions (20.3%, 13/64) being the most common. Of these, 69.2% (9/13) occurred during the initial infusion and 84.6% (11/13) did not recur. ARIA-H (microhemorrhages/superficial siderosis) and ARIA-E (edema/effusion) were observed in 9.4% (6/64) and 3.1% (2/64) of participants, respectively, with only two symptomatic cases (one ARIA-E presenting with headache and one ARIA-H with visual disturbances). After 6 months of treatment, cognitive scores remained stable compared to baseline (MMSE: 22.33 ± 5.58 vs . 21.27 ± 4.30, P = 0.733; MoCA: 16.38 ± 6.67 vs . 15.90 ± 4.78, P = 0.785; CDR-SB: 2.30 ± 1.65 vs . 3.16 ± 1.72, P = 0.357), while significantly increasing plasma amyloid-β 42 (Aβ42) (+21.42%) and Aβ40 (+23.53%) levels compared to baseline.
CONCLUSIONS:
Lecanemab demonstrated a favorable safety profile in Chinese patients with early AD. Cognitive stability and biomarker changes over 6 months suggest potential efficacy, though high dropout rates and absence of a control group warrant cautious interpretation. These findings provide preliminary real-world evidence for lecanemab's use in China, supporting further investigation in larger controlled studies.
REGISTRATION
ClinicalTrials.gov , NCT07034222.
Humans
;
Alzheimer Disease/drug therapy*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Cognitive Dysfunction/drug therapy*
;
Aged, 80 and over
;
Amyloid beta-Peptides/metabolism*
;
Biomarkers
;
East Asian People
4.Risk prediction of Reduning Injection batches by near-infrared spectroscopy combined with multiple machine learning algorithms.
Wen-Yu JIA ; Feng TONG ; Heng-Xu LIU ; Shu-Qin JIN ; Yong-Chao ZHANG ; Chen-Feng ZHANG ; Zhen-Zhong WANG ; Xin ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2025;50(2):430-438
In this paper, near-infrared spectroscopy(NIRS) was employed to analyze 129 batches of commercial products of Reduning Injection. The batch reporting rate was estimated according to the report of Reduning Injection in the direct adverse drug reaction(ADR) reporting system of the drug marketing authorization holder of the Center for Drug Reevaluation of the National Medical Products Administration(National Center for ADR Monitoring) from August 2021 to August 2022. According to the batch reporting rate, the samples of Reduning Injection were classified into those with potential risks and those being safe. No processing, random oversampling(ROS), random undersampling(RUS), and synthetic minority over-sampling technique(SMOTE) were then employed to balance the unbalanced data. After the samples were classified according to appropriate sampling methods, competitive adaptive reweighted sampling(CARS), successive projections algorithm(SPA), uninformative variables elimination(UVE), and genetic algorithm(GA) were respectively adopted to screen the features of spectral data. Then, support vector machine(SVM), logistic regression(LR), k-nearest neighbors(KNN), naive bayes(NB), random forest(RF), and artificial neural network(ANN) were adopted to establish the risk prediction models. The effects of the four feature extraction methods on the accuracy of the models were compared. The optimal method was selected, and bayesian optimization was performned to optimize the model parameters to improve the accuracy and robustness of model prediction. To explore the correlations between potential risks of clinical use and quality test data, TreeNet was employed to identify potential quality parameters affecting the clinical safety of Reduning Injection. The results showed that the models established with the SVM, LR, KNN, NB, RF, and ANN algorithms had the F1 scores of 0.85, 0.85, 0.86, 0.80, 0.88, and 0.85 and the accuracy of 88%, 88%, 88%, 85%, 91%, and 88%, respectively, and the prediction time was less than 5 s. The results indicated that the established models were accurate and efficient. Therefore, near infrared spectroscopy combined with machine learning algorithms can quickly predict the potential risks of clinical use of Reduning Injection in batches. Three key quality parameters that may affect clinical safety were identified by TreeNet, which provided a scientific basis for improving the safety standards of Reduning Injection.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/administration & dosage*
;
Machine Learning
;
Algorithms
;
Humans
;
Quality Control
5.Clinical research and characteristic analysis of patients with advanced colorectal cancer treated with Yinyang Gongji Pills and capecitabine.
Lei WANG ; Chao-Yue YAO ; Jie-Ru ZHAN ; Xiao-Xia SUN ; Zhong-Xin YU ; Xiao-Ya LIANG ; Jian WANG ; Xue GONG ; Da-Rong WEI
China Journal of Chinese Materia Medica 2025;50(5):1404-1411
Yinyang Gongji Pills have the effects of strengthening the body resistance to eliminate pathogenic factors, removing stasis, and reducing swelling, which is a commonly used traditional Chinese medicine(TCM) formula for treating intestinal accumulation. A real-world, registered, and single-arm clinical trial was conducted to observe the clinical efficacy and safety of Yinyang Gongji Pills combined with capecitabine in the treatment of advanced colorectal cancer and analyze the clinical characteristics of the patients. A total of 60 patients with advanced colorectal cancer who refused or could not tolerate standard treatment of western medicine were included in the study. They were treated with Yinyang Gongji Pills combined with capecitabine until disease progression or intolerable adverse events occurred. The main observation indicators were progression-free survival(PFS) and safety. The treatment effects of the patients under different baseline characteristics were analyzed. The clinical trial has found that the median PFS of all enrolled patients was 7.3 months, with 30.1% of patients having a PFS exceeding 12.0 months. Layered analysis showed that the median PFS of patients with the onset site being the colon and rectum were respectively 8.4 and 4.7 months. The median PFS of patients with high, medium, and low tumor burden were respectively 7.0, 4.7, and 10.8 months. The median PFS of patients with wild-type and mutant-type RAS/BRAF were respectively 7.9 and 6.9 months. The median PFS of patients with KPS scores ≥80 and ≤70 were respectively 7.9 and 6.5 months. The median PFS of patients treated with Yinyang Gongji Pills for ≥6, 3-6, and ≤3 months were respectively 8.0, 5.2, and 4.2 months. The median PFS of patients with spleen, kidney, liver, and lung syndrome differentiation in TCM were respectively 8.3, 6.7, 7.3, and 5.6 months. The median PFS of patients with TCM pathological factors including phlegm, dampness, and blood stasis were respectively 7.0, 7.3, and 6.5 months. Common adverse reactions include anemia, decreased white blood cells, decreased appetite, fatigue, and hand foot syndrome, with incidence rates being respectively 44.2%, 34.6%, 42.3%, 32.7%, and 17.3%. The results showed that the combination of Yinyang Gongji Pills and capecitabine demonstrated potential clinical efficacy and good safety in this study. The patients have clinical characteristics such as low tumor burden, onset site at the colon, KPS scores ≥ 80, long duration of oral TCM, and TCM syndrome differentiation including spleen or liver.
Humans
;
Capecitabine/adverse effects*
;
Colorectal Neoplasms/mortality*
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Middle Aged
;
Female
;
Aged
;
Adult
;
Treatment Outcome
6.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
7.Erratum: Author correction to "Generation of αGal-enhanced bifunctional tumor vaccine" Acta Pharm Sin B 12 (2022) 3177-3186.
Jian HE ; Yu HUO ; Zhikun ZHANG ; Yiqun LUO ; Xiuli LIU ; Qiaoying CHEN ; Pan WU ; Wei SHI ; Tao WU ; Chao TANG ; Huixue WANG ; Lan LI ; Xiyu LIU ; Yong HUANG ; Yongxiang ZHAO ; Lu GAN ; Bing WANG ; Liping ZHONG
Acta Pharmaceutica Sinica B 2025;15(2):1207-1207
[This corrects the article DOI: 10.1016/j.apsb.2022.03.002.].
8.Gadopiclenol,a new radiological diagnostic drug used in magnetic resonance imaging
Lu ZHENG ; Ting YANG ; Chao-Yang CHEN ; Ran WEI ; Xuan-Ling ZHANG ; Jing-Zhong DENG ; Ying ZHOU
The Chinese Journal of Clinical Pharmacology 2024;40(11):1661-1664
Gadopiclenol was used in adults and pediatric patients 2 years of age and older during magnetic resonance imaging(MRI)to detect and view lesions of the central nervous system(brain,spine,and associated tissues)and body(head and neck,chest,abdomen,pelvis,and musculoskeletal system)with abnormal vascular properties.Gadopiclenol is a new type of macrocyclic gadolinium-based contrast agent(GBCA).In this article,the molecular structure,principle of action,pharmacodynamics,pharmacokinetics,clinical studies,safety and other aspects of Gadopiclenol were reviewed,in order to introduce the current research status and existing achievements of Gadopiclenol.
9.MRI texture features combined with apparent diffusion coefficient for differentiating uterine sarcoma and cellular uterine leiomyoma
Zhong YANG ; Baoyue FU ; Yulan CHEN ; Naiyu LI ; Mengshi FANG ; Mingjie SUN ; Chao WEI
Chinese Journal of Medical Imaging Technology 2024;40(7):1052-1057
Objective To observe the value of MRI texture features combined with apparent diffusion coefficient(ADC)for differentiating uterine sarcoma(US)and cellular uterine leiomyoma(CUL).Methods Pelvic MRI data of 27 US patients(US group)and 34 CUL patients(CUL group)were retrospectively analyzed.The texture features of lesions were extracted from T2WI and diffusion weighted imaging(DWI),the ADC value were measured,and the average ADC value(ADCmean),the minimum ADC value(ADCmin)and standard ADC value(ADCst)were recorded.Then logistic regression(LR)models were constructed based on ADC value,optimal texture features alone and their combination,respectively,including LRADC,LRtexture and LRADC+texture models.Receiver operating characteristic curves were drawn,and the area under the curves(AUC)were calculated to evaluate the efficacy of each model for differentiating US and CUL.Results The ADCmean,ADCmin and ADCst in US group were all lower than those in CUL group(all P<0.05).A total of 3 750 texture features were extracted from pelvic T2WI and DWI,5 optimal features were finally obtained,and the constructed LRADC+texture model and LRtexture model had similar efficacy of differentiating US and CUL(AUC=0.921,0.887;P>0.05),which were both higher than that of LRADC model(AUC=0.696;both P<0.05).The calibration curve of LRADC+texture model was basically consistent with the ideal curve,which had better clinical benefits than LRADC and LRtexture models.Conclusion MRI texture features combined with ADC value could improve efficacy for differentiating US and CUL.
10.Biomechanical study of load-bearing stability of Pilon fracture fixed with external fixator.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Yang CHEN ; Chao-Lu WANG ; Guang-Wei LIU ; Chang-Long SHI ; Xiao-Yu HUANG ; Yi-Li CHEN ; Hong-Ying CHEN ; Xiong-Wei WANG ; Ji-Yang ZHAO
China Journal of Orthopaedics and Traumatology 2024;37(12):1196-1201
OBJECTIVE:
To explore weight-bearing stability of Pilon fracture fixed by external fixator.
METHODS:
Six ankle bone models (right side) and 4 pairs (8 ankle cadaver specimens) were selected. Pilon fracture model was prepared by using the preset osteotomy line based on Ruedi Allgower Pilon fracture type. Pilon fracture model was built by using a minimally invasive osteotomy. After ankle bone model and cadaver specimen model were fixed with external fixator, axial load was carried out on mechanical loading machine. After ankle bone model and cadaver specimen model were fixed with external fixator, axial load was carried out on mechanical loading machine. Axial loads of 150, 300 and 450 N were applied to ankle bone model, and displacements of fibula fracture blocks, lateral tibia fracture blocks and medial tibia fracture blocks in three-dimensional space (X, Y and Z axes) were recorded by dynamic capture instrument. Axial loads of 300, 600 and 900 N were applied to ankle cadaver model fixed by external fixator. X-ray films of Pilon fracture cadaver model fixed by external fixator under different loading conditions were taken. The anterior tibial angle, tibial malleolar point angle, talus shift value, talus tilt angle, lateral malleolar shift value, lateral malleolar shift value, medial malleolar separation shift value and articular surface step displacement value were measured under different loads by digimizer software.
RESULTS:
After 150, 300 and 450 N axial loads were applied to Pilon fracture models fixed by external fixator, no loosening or fracture of external fixator was observed, and no loosening, fracture or irreversible plastic deformation of Kirschner needle were observed. The displacement values of fibular fracture pieces on X-axis(around) were 0.032 (-0.022, 0.269), 0.061 (-0.002, 0.427), 0.212(-0.016, 1.223) mm, and the displacement values on Y-axis(above and below) were 0.002(-0.031, 0.103), 0.051(-1.133, 0.376), 0.128 (-1.394, 0.516) mm, and displacement values on Z-axis (front and rear) were -0.003 (-0.130, 0.171), 0.137 (-0.076, 0.433), 0.030(-0.487, 0.478) mm;the displacement values of lateral tibial fractures on X-axis were 0.000(-0.108, 0.027), 0.083(-0.364, 0.050), -0.121(-0.289, 0.165) mm, and displacement values on Y-axis were -0.009(-0.200, 0.025), -0.179(-0.710, 0.084), -0.257(-0.799, 0.027) mm, and displacement values on Z-axis were 0.112(-0.024, 0.256), 0.157(-0.068, 0.293), -0.210(-0.035, 0.430) mm;the displacement values of medial tibial fracture block on X-axis were -0.010(-0.060, 0.013), -0.165(-0.289, 0.056), -0.181(-0.395, 0.013) mm, and the displacement values on Y-axis were -0.036(-0.156, 0.007), -0.104(-0.269, 0.178), -0.245(-0.380, -0.011) mm, and displacement values on Z-axis were -0.005(-0.372, 0.189), -0.012 (-1.774, 0.380), 0.200 (-1.963, -0.540) mm. After 300, 600 and 900 N axial loads were applied to Pilon fracture cadaverous models fixed with external fixators, there were no significant difference in anterior tibial angles, angles of malleolar points of tibia, oblique angles of talus, fracture steps, shift values of talus, lateral shift values of lateral malleolus, lateral shift values of medial malleolus, lateral shift values of medial malleolus between under different loading conditions and those without loading (P>0.05). No loosening or fracture of external fixator as a whole, loosening, fracture or irreversible deformation of Kirschner needle at the local fixed fracture end occurred.
CONCLUSION
The early weight-bearing external fixator could maintain stability of fracture end and ankle joint, and the maximum weight is not more than 300 N. In clinical practical application, material characteristics of the implant and type of fracture should be selected.
Humans
;
Weight-Bearing
;
Biomechanical Phenomena
;
External Fixators
;
Tibial Fractures/physiopathology*
;
Fracture Fixation/instrumentation*
;
Male

Result Analysis
Print
Save
E-mail