1.Expert consensus on prognostic evaluation of cochlear implantation in hereditary hearing loss.
Xinyu SHI ; Xianbao CAO ; Renjie CHAI ; Suijun CHEN ; Juan FENG ; Ningyu FENG ; Xia GAO ; Lulu GUO ; Yuhe LIU ; Ling LU ; Lingyun MEI ; Xiaoyun QIAN ; Dongdong REN ; Haibo SHI ; Duoduo TAO ; Qin WANG ; Zhaoyan WANG ; Shuo WANG ; Wei WANG ; Ming XIA ; Hao XIONG ; Baicheng XU ; Kai XU ; Lei XU ; Hua YANG ; Jun YANG ; Pingli YANG ; Wei YUAN ; Dingjun ZHA ; Chunming ZHANG ; Hongzheng ZHANG ; Juan ZHANG ; Tianhong ZHANG ; Wenqi ZUO ; Wenyan LI ; Yongyi YUAN ; Jie ZHANG ; Yu ZHAO ; Fang ZHENG ; Yu SUN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(9):798-808
Hearing loss is the most prevalent disabling disease. Cochlear implantation(CI) serves as the primary intervention for severe to profound hearing loss. This consensus systematically explores the value of genetic diagnosis in the pre-operative assessment and efficacy prognosis for CI. Drawing upon domestic and international research and clinical experience, it proposes an evidence-based medicine three-tiered prognostic classification system(Favorable, Marginal, Poor). The consensus focuses on common hereditary non-syndromic hearing loss(such as that caused by mutations in genes like GJB2, SLC26A4, OTOF, LOXHD1) and syndromic hereditary hearing loss(such as Jervell & Lange-Nielsen syndrome and Waardenburg syndrome), which are closely associated with congenital hearing loss, analyzing the impact of their pathological mechanisms on CI outcomes. The consensus provides recommendations based on multiple round of expert discussion and voting. It emphasizes that genetic diagnosis can optimize patient selection, predict prognosis, guide post-operative rehabilitation, offer stratified management strategies for patients with different genotypes, and advance the application of precision medicine in the field of CI.
Humans
;
Cochlear Implantation
;
Prognosis
;
Hearing Loss/surgery*
;
Consensus
;
Connexin 26
;
Mutation
;
Sulfate Transporters
;
Connexins/genetics*
2.Effects of long-term 2.65 GHz radiofrequency radiation on inflammatory response and intestinal microbiota in mice
Keqin LI ; Yanhui HAO ; Ying LIU ; Jun WANG ; Hongyan ZUO ; Hong YANG ; Yang LI ; Hua DENG
Journal of Army Medical University 2025;47(15):1815-1824
Objective To investigate the effects of long-term radiofrequency(RF)radiation at 2.65 GHz on behavior,inflammatory response,and intestinal microecology in mice in order to provide a basis for the safety assessment of long-term RF exposure.Methods One hundred and eight male C57BL/6N mice(17~21 g,6~8 weeks old)were randomly assigned to a control group(Con)and a RF exposure group.The mice of the RF exposure group were subjected to whole-body uniform exposure to 2.65 GHz RF radiation in an electromagnetic reverberation chamber for 3 h/day for 28 consecutive days.RF field distribution and changes in core body temperature were monitored using an electromagnetic radiation analyzer and a fiber-optic temperature probe,respectively.Cognitive function was assessed using the Y-maze and novel object recognition(NOR)test.Anxiety-like behaviors were evaluated through open field test(OFT)and elevated plus maze(EPM),while depressive-like behaviors were examined with sucrose preference test(SPT)and tail suspension test(TST).HE staining was used to observe the histopathological changes in mouse tissues.Radioimmunoassay(RIA)was employed to detect the expression of pro-inflammatory cytokines,TNF-α and IL-1 β,as well as anti-inflammatory cytokines,IL-4 and IL-10 in the serum,brain,jejunum,and spleen samples.Additionally,metagenomic sequencing was performed to assess alterations in the gut microbiota composition.Results Long-term RF radiation led to a maximal increase of 0.59℃in the core body temperature,but had no significant effects on cognitive function,anxiety-like behaviors,or depressive-like behaviors,or apparent damage of the hippocampal or jejunal tissues in the exposed mice.However,RF exposure significantly up-regulated the expression of the pro-inflammatory cytokine TNF-α in serum(P<0.05),and did not significantly alter the concentrations of other cytokines(IL-1β,IL-4,IL-10),caused significant decrease in α-diversity of the intestinal microbiota(P<0.01),with reduced relative abundances of Ligilactobacillus murinus and Acetatifactor muris(P<0.05),while elevated abundances of Lachnospiraceae bacterium(P<0.01).Conclusion Long-term exposure to 2.65 GHz RF radiation induces systemic inflammatory responses and disrupts gut microbiota homeostasis in mice.
3.Roles of oligodendrocytes in cognitive impairment induced by microwave radiation in mice
Jun WANG ; Yujie LIU ; Xuefeng YANG ; Keqin LI ; Ying LIU ; Zhe YANG ; Yumeng YE ; Zehang LIU ; Hongyan ZUO ; Yanhui HAO ; Yang LI
Military Medical Sciences 2025;49(10):738-746
Objective To investigate the functional changes of oligodendrocytes in a mouse model of cognitive impairment induced by microwave radiation and the mechanism.Methods C57BL/6N male mice were exposed to S-band microwave at 2.856 GHz and 8 mW/cm2 for 15 min.The rectal temperature of mice was monitored by an optical fiber thermometer during microwave radiation.The changes of autonomous exploration behavior and learning and memory ability of mice on the 1st and 7th days after microwave radiation were detected via the open field test and novel object recognition test.Immunofluorescence was used to detect the expression and distribution of neuroglia-2 proteoglycan(NG2)and myelin basic protein(MBP)in the hippocampus of mice on the 1st and 7th days after radiation.Clemastine fumarate,a drug that promoted the maturation of oligodendrocyte precursor cells was administered by gavage,and the expression levels of brain-derived neurotrophic factor(BDNF)and fibroblast growth factor 2(FGF2)in hippocampal tissues were detected by radioimmunoassay at 1 and 7 days after radiation.The changes of myelin sheath structure an 1 and 7 days after radiation were observed by transmission electron microscopy.The effects of clemastine fumarate on learning and memory impairment induced by microwave exposure in mice were assessed via open field and new object recognition experiments.Results Under the experimental conditions,the rectal temperature in mice caused by microwave radiation increased by less than 1 ℃,which was within the thermal safety range of the body.The open field test showed that compared with the control group,the microwave radiation group didn't change significant in terms of movement speedon the 1st and 7th days,but the time spent exploring in the central area was significantly reducedon the 1st day after radiation(P<0.05).In the novel object recognition test,the indexes of the mice on the 1st day were significantly reduced(P<0.05),indicating that the anxiety like behavior and cognitive function of the mice were impaired after microwave radiation.Compared with the control group,the proportion of NG2+area in the hippocampus was significantly decreased(P<0.05)in the microwave radiation group,while that of MBP+area hardly changed on the 1st day after microwave radiation(P>0.05).The expression level of oligodendrocyte related BDNF in the hippocampus was significantly decreased(P<0.05).The myelin of the corpus callosum was broken,and the myelin g ratio was significantly increased(P<0.05),suggesting that micro wave radiation could reduce the number of oligodendrocyte precursors and damage the secretion and myelin function of oligodendrocyte.Compared with the radiation group,the expression levels of BNDF and FGF2 in the radiation combined with clemastine fumarate group were up-regulated,the myelin g ratio was significantly decreased on the 1st day after radiation(P<0.05),and the novel object recognition index was significantly increased(P<0.05).Conclusion Pulsed microwave radiation below the body's fever threshold can cause cognitive dysfunction and other brain damage in mice.The impaired secretion and myelin function of oligodendrocytes and the decreased self-repair ability are the important mechanisms of cognitive dysfunction induced by microwave radiation.
4.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
5.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
6.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
7.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.

Result Analysis
Print