1.A dosimetric study of non-coplanar VMAT and non-coplanar IMRT in HA-WBRT+SIB for brain metastases
Huaqu ZENG ; Zongyou CHEN ; Shukui TANG ; Zunbei WEN ; Qibin WU
China Medical Equipment 2024;21(12):25-31
Objective:To investigate the dosimetric differences between non-coplanar volumetric modulated arc therapy (VMAT) and non-coplanar fixed-field intensity-modulated radiotherapy (IMRT) of Monaco treatment planning system (TPS) in hippocampus-avoidance whole-brain radiation therapy with simultaneous integrated boost(HA-WBRT+SIB) for brain metastases,so as to provide a practical and feasible treatment plan for clinical work. Methods:A total of 22 patients with brain metastases were retrospectively selected. Two radiotherapy plans,which included non-coplanar VMAT and non-coplanar fixed field IMRT of HA-WBRT+SIB,were designed for each patient. The dose distribution,the machine units (MU) of plan,and verification of pre-treatment plan in target area and organs at risk (OARs) between two plans were compared under meeting the prescribed dose requirements of target volume. Results:There were no significant differences in covered volumes (V50 and V55) of 50 and 55 Gy dose,maximum dose (Dmax),heterogeneity index(HI) and conformity index(CI) of planning gross tumor volume(PGTV) between the two plans (P>0.05). For whole-brain planning target volume (PTV-brain-SIB),there was no significant difference in the dose that was covered by 98% volume (D98%) between IMRT and VMAT (P<0.05). VMAT plan could significantly improve the covered volume of 30 Gy dose (V30) of PTV-brain-SIB,and decrease HI value and increase CI value,and the differences of them between VMAT and IMRT were significant (t=-6.366,3.289,-8.343,P<0.05),respectively. The Dmax values of left and right eyes of VMAT plan were significantly lower than those of IMRT plan,and the differences were significant (t=5.784,5.351,P<0.05),respectively. The Dmax value of right inner ear of VMAT plan was higher than that of IMRT plan,and the difference was significant (t=-2.848,P<0.05). VMAT could significantly increase D100% value of left and right hippocampus,which was higher than that of IMRT plan,and the differences of them between two plans were significant (t=-2.564,-6.578,P<0.05),respectively. The MU of IMRT plan was significantly lower than that of VMAT plan,and the difference was significant (t=-6.249,P<0.05). The treatment time of VMAT plan was (294.1±16.4) s,which was significantly less than that of IMRT plan,and the difference of that between two plans was significant (t=-7.400,P<0.001). Under the standards of 3%/2 mm and 2%/2 mm of γ analysis,the γ pass rates of IMRT plan were respectively (99.1±0.6)% and (97.6%±1.0)%,which were significantly higher than those of VMAT plan,and the differences of them were significant (t=-2.733,t=-5.780,P<0.001),respectively. Conclusion:The non-coplanar VMAT and non-coplanar fixed field IMRT based on the Monaco TPS can produce clinically acceptable results for HA-WBRT+SIB in patients with brain metastases. Compared with IMRT,VMAT has better advantage in dose distribution of target volume,and higher treatment efficiency,but IMRT can better protect the hippocampus and reduce the number of MU.
2.A dosimetric study of non-coplanar VMAT and non-coplanar IMRT in HA-WBRT+SIB for brain metastases
Huaqu ZENG ; Zongyou CHEN ; Shukui TANG ; Zunbei WEN ; Qibin WU
China Medical Equipment 2024;21(12):25-31
Objective:To investigate the dosimetric differences between non-coplanar volumetric modulated arc therapy (VMAT) and non-coplanar fixed-field intensity-modulated radiotherapy (IMRT) of Monaco treatment planning system (TPS) in hippocampus-avoidance whole-brain radiation therapy with simultaneous integrated boost(HA-WBRT+SIB) for brain metastases,so as to provide a practical and feasible treatment plan for clinical work. Methods:A total of 22 patients with brain metastases were retrospectively selected. Two radiotherapy plans,which included non-coplanar VMAT and non-coplanar fixed field IMRT of HA-WBRT+SIB,were designed for each patient. The dose distribution,the machine units (MU) of plan,and verification of pre-treatment plan in target area and organs at risk (OARs) between two plans were compared under meeting the prescribed dose requirements of target volume. Results:There were no significant differences in covered volumes (V50 and V55) of 50 and 55 Gy dose,maximum dose (Dmax),heterogeneity index(HI) and conformity index(CI) of planning gross tumor volume(PGTV) between the two plans (P>0.05). For whole-brain planning target volume (PTV-brain-SIB),there was no significant difference in the dose that was covered by 98% volume (D98%) between IMRT and VMAT (P<0.05). VMAT plan could significantly improve the covered volume of 30 Gy dose (V30) of PTV-brain-SIB,and decrease HI value and increase CI value,and the differences of them between VMAT and IMRT were significant (t=-6.366,3.289,-8.343,P<0.05),respectively. The Dmax values of left and right eyes of VMAT plan were significantly lower than those of IMRT plan,and the differences were significant (t=5.784,5.351,P<0.05),respectively. The Dmax value of right inner ear of VMAT plan was higher than that of IMRT plan,and the difference was significant (t=-2.848,P<0.05). VMAT could significantly increase D100% value of left and right hippocampus,which was higher than that of IMRT plan,and the differences of them between two plans were significant (t=-2.564,-6.578,P<0.05),respectively. The MU of IMRT plan was significantly lower than that of VMAT plan,and the difference was significant (t=-6.249,P<0.05). The treatment time of VMAT plan was (294.1±16.4) s,which was significantly less than that of IMRT plan,and the difference of that between two plans was significant (t=-7.400,P<0.001). Under the standards of 3%/2 mm and 2%/2 mm of γ analysis,the γ pass rates of IMRT plan were respectively (99.1±0.6)% and (97.6%±1.0)%,which were significantly higher than those of VMAT plan,and the differences of them were significant (t=-2.733,t=-5.780,P<0.001),respectively. Conclusion:The non-coplanar VMAT and non-coplanar fixed field IMRT based on the Monaco TPS can produce clinically acceptable results for HA-WBRT+SIB in patients with brain metastases. Compared with IMRT,VMAT has better advantage in dose distribution of target volume,and higher treatment efficiency,but IMRT can better protect the hippocampus and reduce the number of MU.
3.Comparison of short-term efficacy of neoadjuvant immunotherapy combined with chemotherapy and neoadjuvant chemoradiation for locally advanced resectable esophageal squamous cell carcinoma
Hai ZHANG ; Jingpei LI ; Zunbei WEN ; Maode CAI ; Kunqiang ZHANG ; Zhuoyi LI ; Jianxing HE ; Jun LIU ; Wanli LIN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(09):1261-1266
Objective To investigate the short-term therapeutic effect of neoadjuvant immunotherapy combined with chemotherapy in the locally advanced esophageal squamous cell carcinoma. Methods The clinical data of patients with esophageal squamous cell carcinoma treated with neoadjuvant treatment in Gaozhou People's Hospital from August 2019 to October 2020 were retrospectively analyzed. According to the different treatments, the patients were divided into two groups: a neoadjuvant immunotherapy combined with chemotherapy group (NIC group) and a neoadjuvant chemoradiotherapy group (NC group). The baseline data, incidence of adverse events during treatment, perioperative indicators, postoperative pathological remission rate and incidence of postoperative complications were compared between the two groups. Results Totally 33 patients were enrolled, including 15 males and 18 females, with an average age of 62.37±7.99 years. There were 17 patients in the NIC group and 16 patients in the NC group. In the NIC group, the carcinoma was mainly located in the middle and lower esophagus, with 5 paitents in stage Ⅱ, 9 patients in stage Ⅲ, and 3 patients in stage Ⅳa. In the NC group, the carcinoma was mainly located in the upper-middle esophagus, with 1 patient in stage Ⅱ and 15 patients in stage Ⅲ. During the neoadjuvant treatment, there was no significant difference in the occurrence of bone marrow suppression or gastrointestinal reactions between the two groups (P>0.05). There were 4 immune-related rashes in the NIC group and 1 esophageal perforation in the NC group. Fourteen (82.35%) patients in the NIC group and 12 (75.00%) patients in the NC group completed the operation on schedule. The postoperative ICU stay time and chest tube indwelling time in the NIC group were shorter than those in the NC group (P<0.05). There were 5 patients of complete remission in the NIC group, and 6 patients in the NC group. There was no significant difference in the pathological regression grade or residual tumor cells between the two groups (P>0.05). There was no significant difference in the incidence of anastomotic fistula, thoracic gastric fistula, bronchial mediastinal fistula, abdominal distension, pulmonary infection, stroke, or hoarseness during the perioperative period between the two groups of patients who completed the operation (P>0.05). In the NC group, 2 patients died during the perioperative period because of thoracic gastric fistula complicated by severe infection. Conclusion Neoadjuvant immunotherapy combined with chemotherapy dose not significantly increase the occurrence of adverse events and shows a good rate of pathological remission, which indicates that the neoadjuvant immunotherapy combined with chemotherapy is a safe, feasible and potential new treatment model.
4.Basic principle and practical application of Elektra linac control software item Part and value ( IPV)
Shukui TANG ; Zongyou CHENG ; Huaqu ZENG ; Zunbei WEN
Chinese Journal of Radiation Oncology 2019;28(8):638-640
Objective To illustrate the basic operational principle of the control software item Part and value ( IPV) of Elekta digital medical linac and specifically explain that the control software monitors and controls the subsystems in a real-time manner by using three types of items and Parts. Methods Firstly, the composition of the control system of Elekta digital medical linac was introduced. Then, the definition and category of the items and Parts of the control software and the basic principle of different types of items were illustrated. Finally, the application of control software items and Parts in real-time monitoring and controlling the operation of subsystems was evaluated by analyzing the motion control of high-power ( HP) phase shifter. Results By analyzing the principle and citing a classical example to specifically illustrate the operational principle and application of control software IPVs, the users, especially the maintenance personnel, could master relevant theoretical knowledge, rapidly and accurately find the operational parameters during daily use and maintenance, besides analyze and resolve the problems based on the control principle of relevant subsystem. Conclusion Users, especially the maintenance personnel who master the working principle of these subprojects and their project sub-items can quickly and accurately check, calibrate the operating parameters via the control software, resolve equipment failure and avoid accidents caused by inappropriate operation in the daily use or maintenance.

Result Analysis
Print
Save
E-mail