1.Evaluation of hemolysis quality of specimens by fully automated blood collection robot
Chong WANG ; Meixiu GU ; Jie ZHU ; Peiqi FANG ; Wenjia TANG ; Zizhong LIU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(8):1080-1084
Objective:To compare the differences in specimen results between the intelligent robotic phlebotomy group and the manual venipuncture group, and to evaluate the clinical applicability of the autonomous blood collection system.Methods:From January 20 to October 28, 2022, 154 volunteers at Zhongshan Hospital, Fudan University underwent paired blood collections (robotic and manual) within 5 minutes. The collected samples were analyzed for: hemolysis index (HI), alanine transaminase (ALT), aspartate transaminase (AST), L-γ-glutamyltransferase (γ-GT), lactate dehydrogenase (LDH), urea nitrogen (UREA), creatinine (CRE), uric acid (UA), glucose (GLU), total cholesterol (TC), triglyceride (TG), natrium (Na), kalium (K), chlorine (Cl), creatine kinase (CK), CK-MB, CK-MM, and neuron-specific enolase (NSE). Statistical analyses used t-tests and Wilcoxon signed-rank tests.Results:The results of two different blood collection methods revealed that the HI values of 154 specimens in the intelligent robot blood collection group were all less than 20SI, while 7 specimens (4.54%) in the manual blood collection group had HI values exceeding 20SI; In the comparison of 17 biochemical and immunological markers, there were statistically significant differences between groups in 8 items including γ-GT[20.00(15.00, 37.75)U/L vs. 19.00 (14.00, 36.25)U/L, Z=2.497, P<0.05], LDH[165.5 (147.0, 183.0)U/L vs. 173.0 (155.0, 193.0)U/L, Z=8.629, P<0.05], TC[(5.002±0.856)mmol/L vs.(5.031±0.870) mmol/L, t=-3.006, P<0.05], K[4.1 (4.0, 4.3)mmol/L vs. 4.3 (4.1, 4.4)mmol/L, Z=5.592, P<0.05], CK[97.00 (73.00, 133.00)U/L vs. 99.00 (74.75, 136.25)U/L, Z=3.490, P<0.05], CK-MB[13 (11, 15)U/L vs. 14 (12, 16)U/L, Z=6.581, P<0.05], CK-MM[84.00 (60.00, 119.00)U/L vs. 83.50 (58.75, 118.00)U/L, Z=3.790, P<0.05], and NSE[10.600 (9.500, 11.700)ng/ml vs. 11.950 (10.475, 13.725)ng/ml, Z=8.151, P<0.05]. Conclusions:In the collection of serum samples, intelligent blood collection robots can achieve standardization and normalization of specimen collection volume and mixing in the pre-analysis stage. The hemolysis related indicators of the collected specimens are lower than those of the manual collection group, and can be used for the collection of clinical serological specimens.
2.Evaluation of hemolysis quality of specimens by fully automated blood collection robot
Chong WANG ; Meixiu GU ; Jie ZHU ; Peiqi FANG ; Wenjia TANG ; Zizhong LIU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(8):1080-1084
Objective:To compare the differences in specimen results between the intelligent robotic phlebotomy group and the manual venipuncture group, and to evaluate the clinical applicability of the autonomous blood collection system.Methods:From January 20 to October 28, 2022, 154 volunteers at Zhongshan Hospital, Fudan University underwent paired blood collections (robotic and manual) within 5 minutes. The collected samples were analyzed for: hemolysis index (HI), alanine transaminase (ALT), aspartate transaminase (AST), L-γ-glutamyltransferase (γ-GT), lactate dehydrogenase (LDH), urea nitrogen (UREA), creatinine (CRE), uric acid (UA), glucose (GLU), total cholesterol (TC), triglyceride (TG), natrium (Na), kalium (K), chlorine (Cl), creatine kinase (CK), CK-MB, CK-MM, and neuron-specific enolase (NSE). Statistical analyses used t-tests and Wilcoxon signed-rank tests.Results:The results of two different blood collection methods revealed that the HI values of 154 specimens in the intelligent robot blood collection group were all less than 20SI, while 7 specimens (4.54%) in the manual blood collection group had HI values exceeding 20SI; In the comparison of 17 biochemical and immunological markers, there were statistically significant differences between groups in 8 items including γ-GT[20.00(15.00, 37.75)U/L vs. 19.00 (14.00, 36.25)U/L, Z=2.497, P<0.05], LDH[165.5 (147.0, 183.0)U/L vs. 173.0 (155.0, 193.0)U/L, Z=8.629, P<0.05], TC[(5.002±0.856)mmol/L vs.(5.031±0.870) mmol/L, t=-3.006, P<0.05], K[4.1 (4.0, 4.3)mmol/L vs. 4.3 (4.1, 4.4)mmol/L, Z=5.592, P<0.05], CK[97.00 (73.00, 133.00)U/L vs. 99.00 (74.75, 136.25)U/L, Z=3.490, P<0.05], CK-MB[13 (11, 15)U/L vs. 14 (12, 16)U/L, Z=6.581, P<0.05], CK-MM[84.00 (60.00, 119.00)U/L vs. 83.50 (58.75, 118.00)U/L, Z=3.790, P<0.05], and NSE[10.600 (9.500, 11.700)ng/ml vs. 11.950 (10.475, 13.725)ng/ml, Z=8.151, P<0.05]. Conclusions:In the collection of serum samples, intelligent blood collection robots can achieve standardization and normalization of specimen collection volume and mixing in the pre-analysis stage. The hemolysis related indicators of the collected specimens are lower than those of the manual collection group, and can be used for the collection of clinical serological specimens.
3.Application effect of preoperative intranasal dexmedetomidine in pediatric anesthesia
Jie LI ; Xiaojuan HU ; Zizhong WANG ; Jie TANG ; Liu XU ; Fei WANG
Chinese Journal of Primary Medicine and Pharmacy 2019;26(3):261-263
Objective To observe the clinical effects of preoperative intranasal dexmedetomidine in pediatric anesthesia.Methods From April 2014 to April 2017,40 pediatric patients who accepted elective circumcision,ASA Ⅰ,aged 2 to 10 years in Wenjiang Branch of Sichan Provincial People's Hospital were divided into two groups,with 20 cases in each group.The test group received intranasal dexmedetomidine 1 μg/kg,and the control group received intranasal equal volume of saline 30 min before surgery.HR,SpO2,BP were monitored and recorded before intranasal (T0),5min after intranasal (T1),10min after intranasal (T2),20min after intranasal (T3),30min after intranasal (T4).The sedation score was assessed after 30 min of administration.The restless score was observed after waking.Results ANOVA analysis showed that there were significant differences in SBP (F =14.54,P < 0.05) and DBP (F =22.69,P < 0.05) between the two groups,and the SBP (F =13.77,P < 0.05),DBP (F =10.48,P < 0.05),HR(F =5.13,P < 0.05) had interaction effects.Compared with those of the control group,the heart rate and the diastolic pressure of the test group were decreased at T2 ~ T4 (all P < 0.05).The sedation score of the test group was superior than that of the control group(t =-9.131,P <0.05),and the postoperative agitation score was lower than that of the control group (t =3.387,P < 0.05).Conclusion Intranasal dexmedetomidine can provide satisfactory sedative effects without affecting the vital signs of children and significantly reducing the postoperative agitation.
4.Construction of a Pichia pastoris recombinant strain capable of over-expressing phytase and endoglucanase.
Zhenfang WU ; Zizhong TANG ; Hui CHEN ; Xueyi HAN ; Xin LAI ; Qi WU
Chinese Journal of Biotechnology 2010;26(5):616-622
Both phytase and endoglucanase are additives in feed for mono-gastric animal known for their effects. Recombinant vector pPICZalpha-EG was constructed and transformed to GS115-phyA, a Pichia pastoris strain that had integrated with phytase gene, generating GS115-phyA-EG. Both phytase and endoglucanase activities in the supernatant were determined after methanol induction of GS115-phyA-EG. Phytase and endoglucanase activity reached 39.4% and 56.2% activity compared to GS115-phyA and GS115-EG, respectively. Properties of the mixed enzyme suggest that the optimal temperature and pH value be 55 degrees C and 5.5 respectively. Both phytase and endoglucanase showed greater than 80% activity across temperature ranges 45 degrees C to 55 degrees C and pH ranges 4.5 to 5.5. Expressing more than one enzyme in one system could save time and money during induced expression, and the mixed enzyme might apply for treating forge before feeding with poultry.
6-Phytase
;
biosynthesis
;
genetics
;
Cellulase
;
biosynthesis
;
genetics
;
Genetic Vectors
;
Pichia
;
enzymology
;
genetics
;
Recombinant Proteins
;
biosynthesis
;
genetics

Result Analysis
Print
Save
E-mail