1.Role of mesenchymal stem cells in pathogenesis of adolescent idiopathic scoliosis:research progress
Zixiang DENG ; Songzhi NI ; Xuan LIU ; Ming LI ; Yushu BAI
Academic Journal of Naval Medical University 2025;46(3):301-306
Adolescent idiopathic scoliosis(AIS)is a complex spinal deformity that occurs in adolescents aged 10-18 years.It is more common in female adolescents.Despite extensive research,the precise pathological mechanisms underlying AIS are yet to be fully elucidated.Given its links to abnormal bone growth and reduced bone mineral density,the involvement of mesenchymal stem cells(MSCs)in bone metabolic disorders is considered a plausible contributing factor of AIS.This review summarizes the role of MSCs in the pathogenesis of AIS and provides a forward-looking perspective on the potential clinical application.
2.Evaluation of the function and activity of masticatory muscles using a self-developed wireless surface electromyography system.
Wenbo LI ; Yujia ZHU ; Qingzhao QIN ; Shenyao SHAN ; Zixiang GAO ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(3):346-353
OBJECTIVES:
This study aimed to evaluate the repeatability and reliability of a self-developed domestic wireless surface electromyography (sEMG) system (Oralmetry) in assessing the activity of the temporalis and masseter muscles to provide theoretical support for its clinical application.
METHODS:
Twenty-two volunteers were recruited. Through multiple repeated measurements, the sEMG signals of bilateral anterior temporalis and masseter muscles during maximum voluntary clenching were collected using the self-developed sEMG device, Oralmetry, and two commercial sEMG devices (Zebris and Teethan), filtered, screened, and standardized. Seven sEMG indicators for assessing masticatory muscle function were calculated. The intraclass correlation coefficient (ICC) was used to evaluate the repeatability of the measurements from the three sEMG devices, and statistical analysis was conducted to compare the consistency of the seven sEMG indicators obtained from the devices.
RESULTS:
Among the 22 participants, the ICC values of the repeated measurements from the three sEMG devices ranged from 0.88 to 0.99. The measurements of three sEMG indicators (antero-posterior coeffificient, percentage overlapping coeffificient_MM, and percentage overlapping coeffificient_TA) obtained by Zebris were significantly different from those obtained by Oralmetry and Teethan (P<0.05). No significant differences in the measurements of the seven sEMG indicators were found between Oralmetry and Teethan.
CONCLUSIONS
Oralmetry and the two commercial sEMG devices demonstrated good repeatability in capturing sEMG indicators for evaluating masticatory muscle function. In particular, Oralmetry showed the highest ICC values. All three devices also exhibited good consistency in measuring sEMG indicators, and a high agreement was observed between the two wireless sEMG devices (Oralmetry and Teethan). These findings provide theoretical support for the clinical application of Oralmetry.
Humans
;
Electromyography/methods*
;
Masseter Muscle/physiology*
;
Masticatory Muscles/physiology*
;
Wireless Technology
;
Reproducibility of Results
;
Temporal Muscle/physiology*
;
Male
;
Adult
;
Female
;
Young Adult
3.Digital design and manufacturing method of double constrained split guide for orthodontic miniscrew implantation.
Xin DU ; Aonan WEN ; Zixiang GAO ; Zhihua LI ; Sheng ZHANG ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(4):603-612
This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.0, Geomagic wrap 2021, and Materialise magics 21.0 were utilized for 3D reconstruction, model integration, and guide design. The guide was then fabricated via laser metal 3D printing. Model and intraoral try-in results demonstrated that the guide fitted well and was stable. Postoperative CBCT verified that the final miniscrew implantation site was consistent with the preoperative design, and no related complications occurred. This double constrained split orthodontic miniscrew guide provides a precise and safe digital solution for clinical miniscrew implantation.
Humans
;
Bone Screws
;
Cone-Beam Computed Tomography
;
Printing, Three-Dimensional
;
Orthodontic Anchorage Procedures/instrumentation*
;
Imaging, Three-Dimensional
;
Computer-Aided Design
4.The diagnostic value of plasma calprotectin in children with refractory mycoplasma pneumoniae pneumonia
Chen Gong ; Hui Gao ; Zixiang Zhan ; Chi Li ; Lulu Fang ; Ji Ma ; Shaohu Huo ; Shenggang Ding
Acta Universitatis Medicinalis Anhui 2025;60(3):535-539
Objective :
To investigate the diagnostic value of plasma calprotectin in childern with refractory mycoplasma pneumoniae pneumonia(RMPP).
Methods :
A multicenter, prospective cohort study was conducted, enrolling 228 children with mycoplasma pneumoniae pneumonia(MPP). Among these, 177 cases were diagnosed with general mycoplasma pneumoniae pneumonia(GMPP), while the remaining 51 cases were RMPP. Plasma was collected at the time of admission of the children in both groups, and calprotectin levels were measured. A one-way difference analysis was performed on the blood test indexes of the children in the two groups, and the difference variables withP<0.05 between the two groups were included in a multifactorial logistic regression to analyze the risk factors for the progression of GMPP to RMPP. The differential diagnostic value of plasma calprotectin for GMPP and RMPP was analyzed by the receiver operating characteristic(ROC) curves.
Results :
Univariate analysis showed that plasma calprotectin levels were significantly higher in the RMPP group than those in the GMPP group, and the difference was statistically significant(P<0.05). Logistic regression analysis showed that plasma calprotectin was an independent risk factor for RMPP(OR=1.323,P<0.001), ROC curve analysis showed that plasma calprotectin had a higher diagnostic value for the differential diagnosis of GMPP and RMPP(AUC =0.839), and its combination with C-reactive protein and albumin could significantly improve the diagnostic efficiency.
Conclusion
Plasma calprotectin has good clinical value for the diagnosis of RMPP.
5.Short-term outcome study on cervical deep lymph node-venous anastomosis technique in the treatment of Alzheimer’s disease
Cheng GAN ; Zhengdong KONG ; Xiaoye RAN ; Shudong QIAO ; Yixin ZHANG ; Lu YUE ; Yingjie WANG ; Hui BI ; Dong YANG ; Hongtong MA ; Yuan CHEN ; Hongli CHAI ; Ying JIA ; Chenhao MA ; Zixiang CHEN ; Ke LI ; Miao WANG ; Liguo XUE ; Siwen ZHAO ; Ke WEN ; Lin YIN ; Bo DING ; Shan ZHU ; Yuanbo LIU ; Mengqing ZANG
Chinese Journal of Plastic Surgery 2025;41(2):130-143
Objective:To explore the short-term clinical effects of deep cervical lymph node-venous anastomosis in the treatment of Alzheimer’s disease (AD).Methods:A prospective exploratory study was conducted on the treatment of AD patients using the cervical deep lymph node-venous anastomosis technique in Scar and Wound Treatment Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, from September to October 2024. The patients underwent high-frequency ultrasound to locate deep cervical lymph nodes and the external jugular vein. Under general anesthesia, bilateral deep cervical lymph node-venous anastomoses were performed. Indocyanine green (ICG) lymphography was conducted via subcutaneous injection behind the ear to visualize lymph nodes in levels Ⅱ and Ⅲ. After making a skin incision along the posterior margin of the sternocleidomastoid muscle, the external jugular vein, internal jugular veins, and associated lymph nodes were exposed. Adjacent veins were selected for anastomosis of lymph node. Using microsurgical techniques, end-to-side or end-to-end anastomosis was completed for lymph nodes in levels Ⅱ and Ⅲ. Preoperative assessments included the mini-mental state examination (MMSE, a higher score indicates better cognitive function), Alzheimer’s disease assessment scale-cognitive subscale (ADAS-Cog, a higher score indicates greater impairment of cognitive function), Alzheimer’s disease cooperative study scale for activities of daily living (ADCS-ADL, a higher score indicates better ability to perform daily activity), and neuropsychiatric inventory (NPI, a higher score indicates more severe behavioral and emotional symptom). Postoperative follow-up included the same scales to observe changes in cognitive function, activities of daily living, and emotional communication.Results:Four patients (1 male, 3 females, aged 58-79 years) with AD were included. All were diagnosed based on cerebrospinal fluid biomarkers. All patients successfully underwent bilateral deep cervical lymph node-venous anastomoses. On average, 4.3 (2-7 per person) anastomoses were performed per patient. Surgical procedures lasted an average of 6.5 h (5.5-8.5 h) with minimal blood loss (less than 50 ml). Patients resumed normal activity within 6 hours postoperatively and were discharged after an average of 4.1 d (3.5-5.0 d). Postoperative complications included one case each of aspiration pneumonia, lower limb venous thrombosis, and transient delirium, all of whom resolved without long-term effects. Clinical symptoms, including memory decline, mood swings, and anxiety, showed varying degrees of improvement. Patients reported enhanced quality of life, emotional stability, and social engagement, confirming the procedure’s safety and potential cognitive benefits. At one month postoperatively, the MMSE scores of the four patients increased by an average of 0.8 points compared to preoperative levels. Additionally, the two patients who completed the ADAS-Cog assessments showed a decrease in their scores (reduced by 1.0 points and 11.3 points, respectively, compared to preoperative scores), indicating a certain degree of improvement in cognitive function during this period. The ADCS-ADL and NPI scores of four patients varied significantly, without showing any clear pattern.Conclusion:Lymphovenous anastomosis of the deep cervical lymph node-venous anastomosis may provide a new surgical intervention approach for AD, but further large-scale studies and long-term follow-up are needed to validate its safety and effectiveness.
6.Comprehensive management ability of Helicobacter pylori screening in primary hospitals of Jiangsu Province
Jinjin SHI ; Zixiang HUANG ; Wei SU ; Cheng LI ; Long YE ; Hailing FENG ; Shuowei XING ; Hongmei YANG ; Guoxin ZHANG ; Feng YE
Chinese Journal of Digestion 2025;45(8):520-525
Objective:Based on the activities of Helicobacter pylori ( HP) screening in Jiangsu Province in 2024, to evaluate the overall management ability in HP screening, testing, treatment and follow-up in primary medical facilities. Methods:From May 15 to October 18, 2024, the data of HP screening and treatment were retrospectively collected from 79 township health centers, community hospitals, and community health service centers in Jiangsu Province. The rates of screening completion, urea breath test (UBT) completion, treatment rate, UBT follow-up completion, and HP eradication were analyzed. Chi-square test was used for statistical analysis. Results:The completion rate of HP screening was 94.45% (15 489/16 400). There were 6 604 cases (42.64%) with serum HP antibody positive among the 15 489 individuals who completed screening. The positive rate of serum HP antibody in males was higher than that in females (44.77%, 2 643/5 904 vs. 41.32%, 3 961/9 585), and the difference was statistically significant ( χ2=17.69, P<0.001). The positive rates of serum HP antibody in screened individuals aged 18 to 19, 20 to 39, 40 to 59, and 60 to 75 years old were 22.38% (32/143), 36.12% (1 168/3 234), 45.01% (3 240/7 199), and 44.05% (2 164/4 913), respectively, and the difference was statistically significant( χ2=100.73, P<0.001). Among the 6 604 HP antibody-positive individuals, 4 381 cases completed UBT, with a UBT completion rate of 66.34% (4 381/6 604). There were 3 197 individuals with both HP serum antibody and UBT positive, the consistency rate of the 2 tests was 72.97% (3 197/4 381). Totally 2 737 cases received treatment, with a treatment completion rate of 85.61% (2 737/3 197); 2 327 individuals underwent UBT follow-up, with a follow-up completion rate of 85.02% (2 327/2 737). During follow-up, the result of UBT was negative in 1 982 individuals, and the HP eradication rate was 85.17% (1 982/2 327). Conclusions:There are deficiencies in the completion rate of HP screening, testing, treatment, and follow-up in primary hospitals, especially in the completion rate of UBT, which may be related to cognitive insufficiency for HP in residents. It is necessary to strengthen the training of physicians′ abilities in primary hospitals, optimize the allocation of drug resources, enhance health education, and increase residents′ participation and compliance.
7.Clinical effect of indocyanine green angiography-assisted design and harvest of expanded flaps for scar reconstruction
Yanan HU ; Tingjun XIE ; Yuanbo LIU ; Shan ZHU ; Zengjie YANG ; Jia TIAN ; Cheng GAN ; Hu JIAO ; Shanshan LI ; Zixiang CHEN ; Lu ZHOU ; Bing HAN ; Shengyang JIN ; Yan ZENG ; Miao WANG ; Mengqing ZANG
Chinese Journal of Burns 2025;41(4):341-347
Objective:To investigate the clinical effect of indocyanine green angiography (ICGA)-assisted design and harvest of expanded flaps for scar reconstruction.Methods:This study was a retrospective observational study. From April 2019 to August 2023, 19 patients with scars (8 males, 11 females; aged 3-38 years) treated at the Plastic Surgery Hospital of Peking Union Medical College and Chinese Academy of Medical Sciences met the inclusion criteria. The scars were distributed on the head, face, trunk, and extremities. In stage Ⅰ surgery, skin soft tissue expanders were implanted in suitable areas around the scars for skin soft tissue expansion. In stage Ⅱ surgery, the scar tissue was excised, resulting in wound areas ranging from 100 to 210 cm 2, and expanded flaps were designed. ICGA was used to identify target perforators and their accompanying veins, and the flap design was adjusted to ensure the inclusion of complete arterial and venous axes. The expanded flap with an area of 120 to 240 cm2 was harvested using unilateral back-cut technique and transferred to the recipient site, and the donor site wound was sutured directly. The durations of the arterial and venous phases of ICGA during flap design were recorded. The length-to-width ratios of the back-cut flaps were calculated for different regions. After stage Ⅱ surgery, the blood perfusion and survival of the flap, the wound healing at the donor site, and the occurrence of complications were observed. During follow-up, the appearance, color, and texture of the patient's flap were observed. Results:The arterial phase of ICGA lasted 10-27 (18±5) s, and the venous phase lasted 78-116 (100±10) s. The length-to-width ratios of the back-cut flaps were 1.22±0.32, 1.63±0.12, and 1.15±0.21 for the head and neck, trunk, and limb regions, respectively. After stage Ⅱ surgery, one patient had a large area of insufficient blood perfusion in the flap. By comparing ICGA images before and after flap transfer, the sutures at the oral commissure were loosened, the blood flow of the flap was restored. The blood perfusion of the flaps in other patients was good. All flaps survived completely, with well-healed donor site wounds and no complications. During 0.5-14.0 months of follow-up, all flaps of patients demonstrated excellent appearance, with color and texture matching the surrounding skin.Conclusions:As a means of superficial blood flow visualization, ICGA can not only clearly show the microvascular distribution of the expanded flap before operation, assist in optimizing the design of the flap, but also evaluate the blood perfusion of the flap after operation, reduce the occurrence of complications, and provide a full-process navigation for the harvesting of expanded flaps, thereby improving the safety of flap transfer for scar reconstruction.
8.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
9.Protective effect of mangiferin on oxidative stress injury in rat bone marrow mesenchymal stem cells
Xiaofeng LI ; Duo ZHAO ; Qin OUYANG ; Zixiang PANG ; Yuquan LI ; Qianfen CHEN
Chinese Journal of Tissue Engineering Research 2025;29(13):2669-2674
BACKGROUND:Mesenchymal stem cell transplantation has a certain effect on spinal cord injury,but there are still some problems such as low survival rate and poor efficiency of cell transplantation caused by local oxidative stress environment.OBJECTIVE:To explore the protective effect of mangiferin on oxidative stress of bone marrow mesenchymal stem cells.METHODS:Rat bone marrow mesenchymal stem cells at passage 3 were added to mangiferin and incubated for 2 hours according to the gradient of concentration (0,20,40,80,and 160 μmol/L).A serum-free medium containing 400 μmol/L H2O2 was added,and a gradient concentration of mangiferin was added again and cultured for 12 and 24 hours.Rat bone marrow mesenchymal stem cells were cultured as normal control group.Cell survival was detected by MTT assay in each group.The superoxide dismutase,malondialdehyde,and catalase in the culture medium were detected in accordance with the instruction of the kit.RESULTS AND CONCLUSION:Compared with normal control group,cell viability in the H2O2 group was significantly decreased (P<0.01),and the levels of superoxide dismutase and catalase were significantly decreased (P<0.01),while the level of malondialdehyde was significantly increased (P<0.01).Compared with H2O2 group,the survival rate of cells was significantly increased (P<0.01),and the levels of superoxide dismutase and catalase were significantly increased (P<0.01),while the level of malondialdehyde was significantly decreased (P<0.01) in the mangiferin group.Mangiferin showed concentration-dependent antioxidant stress protective activity above 20 μmol/L,and no cytotoxicity below 160 μmol/L.These findings indicate that antioxidant mangiferin can increase the antioxidant activity of bone marrow mesenchymal stem cells and provide a new preconditioning strategy for bone marrow mesenchymal stem cell transplantation.
10.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.


Result Analysis
Print
Save
E-mail