1.Application value of total cerebral small vessel disease score combined with three-dimensional arterial spin labeling in predicting the prognosis of patients with acute ischemic stroke after intravenous thrombolysis
Journal of Apoplexy and Nervous Diseases 2026;43(1):15-19
Objective To investigate the value of total cerebral small vessel disease (CSVD) score combined with three-dimensional arterial spin labeling (3D-ASL) in predicting the prognosis of patients with acute ischemic stroke (AIS) after 90 days of intravenous thrombolysis. Methods A total of 189 AIS patients who were consecutively admitted to Department of Neurology, Changshu Hospital Affiliated to Nantong University, from January 2021 to June 2023 and underwent intravenous thrombolysis with alteplase were enrolled, and multimodal brain MRI was performed to assess total CSVD load and cerebral blood flow in the area of responsibility. A multivariate logistic regression analysis was used to identify the independent influencing factors for poor 90-day prognosis in AIS patients undergoing intravenous thrombolysis. The receiver operating characteristic (ROC) curve was used to investigate the value of total CSVD score and 3D-ASL used alone or in combination in predicting the prognosis of AIS. Results The multivariate regression analysis showed that diabetes (OR=3.601,95%CI 1.448‒8.954,P=0.006), total CSVD score ≥3 points (OR=4.077, 95%CI 1.785‒9.313,P=0.001), and baseline NIHSS score (for every 1-point increase:OR=1.167, 95%CI 1.061‒1.283, P=0.001) were independent risk factors for poor prognosis in AIS patients on day 90 after intravenous thrombolysis,while ASL hyperperfusion was an independent protective factor against poor prognosis (OR=0.16, 95%CI 0.050‒0.356,P=0.014).The ROC curve analysis showed that the predictive model based on CSVD score and ASL perfusion had a C-value of 0.844 (95%CI 0.786‒0.902, P<0.05) and thus had the best predictive efficacy. Conclusion Total CSVD score combined with 3D-ASL can more comprehensively reflect the whole brain circulation network and has a better effect than each indicator alone in predicting the 90-day prognosis of AIS patients undergoing intravenous thrombolysis.
2.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
3.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
4.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
5.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
6.High expression of SURF4 promotes migration, invasion and proliferation of gastric cancer cells by inhibiting tight junction proteins.
Ziliang WANG ; Xiaohua CHEN ; Jingjing YANG ; Chen YAN ; Zhizhi ZHANG ; Bingyi HUANG ; Meng ZHAO ; Song LIU ; Sitang GE ; Lugen ZUO ; Deli CHEN
Journal of Southern Medical University 2025;45(8):1732-1742
OBJECTIVES:
To study the impact of SURF4 expression level on long-term prognosis of gastric cancer (GC) and biological behaviors of GC cells.
METHODS:
SURF4 expression level in GC and its association with long-term patient prognosis were analyzed using publicly available databases and in 155 GC patients with low and high SURF4 expressions detected immunohistochemically. The Cox proportional hazard model and Kaplan-Meier survival curves were used to analyze independent prognostic predictors of GC and the 5-year survival rate of the patients with different SURF4 expression levels. Informatics analyses were conducted to explore the correlation of SURF4 expression level with immune cell infiltration in GC, SURF4-related differential genes and their associated pathways. In cultured GC cell line HGC-27, the effects of SURF4 knockdown and overexpression on proliferation, migration, invasion and epithelial-mesenchymal transition (EMT) were investigated.
RESULTS:
Analysis of GEPIA dataset and immunohistochemical results suggested significant SURF4 overexpression in GC (P<0.05), which was associated with shortened 5-year survival time of the patients (χ2=38.749, P<0.001). The prognosis of GC was closely related to tumor stage T3-4, N2-3, CEA≥5 μg/L and CA19-9≥37 kU/L (P<0.05). SURF4 expression level was negatively correlated with activated B cells, NK cells and CD8+ effector memory T cells (P<0.05) and positively correlated with CD4+ T cells (P<0.05). GO and KEGG enrichment analysis suggested that SUFR4 may participate in GC carcinogenesis by promoting EMT through the tight junction pathway. In HGC-27 cells, SURF4 overexpression significantly decreased E-cadherin expression, increased N-cadherin expression, inhibited ZO-1 and claudin-1 expressions, and promoted cell proliferation, migration and invasion.
CONCLUSIONS
SURF4 is highly expressed in GC, and its overexpression is associated with a shortened 5-year survival of the patients possibly by enhancing tumor cell proliferation, migration and invasion via inhibiting tight junction proteins and promoting EMT.
Humans
;
Stomach Neoplasms/metabolism*
;
Cell Proliferation
;
Cell Movement
;
Epithelial-Mesenchymal Transition
;
Cell Line, Tumor
;
Neoplasm Invasiveness
;
Prognosis
;
Tight Junction Proteins/metabolism*
;
Membrane Proteins/metabolism*
;
Female
;
Male
7.Advances in multi-source surveillance data integration and application of early warning indicators for respiratory infectious diseases
Dazhu HUO ; Ting ZHANG ; Jinzhao CUI ; Xiaochen ZHANG ; Yongtao CHI ; Yanan WANG ; Zhe WANG ; Xin ZHAO ; Ziliang FAN ; Chuchu YE ; Chuangsen FANG ; Yanming LI ; Zhongjie LI ; Weizhong YANG ; Chen WANG
Chinese Journal of Preventive Medicine 2025;59(8):1311-1319
The integration of multi-source data and the establishment of early warning indicator systems constitute pivotal elements for advancing surveillance and early warning capacities in respiratory infectious diseases. Given the multifaceted transmission mechanisms and complex contributing factors inherent in respiratory infectious diseases, surveillance datasets and associated early warning indicators demonstrate notable heterogeneity and sophisticated interrelationships. Furthermore, as surveillance and early warning requirements significantly vary across diverse epidemiological scenarios, accurate assessment of the value and applicability of distinct data types and indicators is imperative. This paper systematically reviews and synthesizes recent advancements in surveillance data and early warning indicators for respiratory infectious diseases, drawing on both domestic and international research. Particular attention is dedicated to analyzing the applicability and efficacy of various data types and indicators within multiple practical contexts, aiming to provide robust theoretical frameworks and methodological guidance to facilitate the development of resilient and efficient surveillance and early warning systems for respiratory infectious diseases.
8.Establishment and application of real-time fluorescent RAA detection method tar-getingspecific gene F57 of Mycobacterium avium subsp.paratuberculosis
Ziliang ZHAO ; Suhui ZHANG ; Jiabei HAN ; Shaomei LI ; Liu YANG ; Lizhi FU ; Kefei SHEN
Chinese Journal of Veterinary Science 2025;45(4):699-706
To rapidly and accurately detect Mycobacterium avium subsp.paratuberculosis(MAP),this study designed and screened primers and probes using its specific gene F57 as the detection target,established a recombinant enzyme-mediated isothermal amplification(RAA)fluorescence detection method,and applied this method to detect 116 clinical samples from cattle and sheep.The results showed that using the primer and probe combination B12F/B2R(0.4 μmol/L)+Probe B(0.12 μmol/L),MAP could be detected at a constant temperature of 42 ℃ within 20 min;this de-tection method had no cross-reaction with 11 common pathogens such as Escherichia coli,Clos-tridium,and bovine viral diarrhea in sheep and cattle;the lowest detection limit was 1.0×102 cop-ies/μL;the coefficient of variation was 3.77%—5.29%;24 clinical samples were positive,with a co-incidence rate of 88.89%with GBT27637-2011.In summary,this study established a fluorescent RAA detection method for MAP,which is simple,rapid,highly specific,sensitive,reproducible,and has a high coincidence rate with national standards,making it suitable for clinical detection and epi-demiological studies.
9.Advances in multi-source surveillance data integration and application of early warning indicators for respiratory infectious diseases
Dazhu HUO ; Ting ZHANG ; Jinzhao CUI ; Xiaochen ZHANG ; Yongtao CHI ; Yanan WANG ; Zhe WANG ; Xin ZHAO ; Ziliang FAN ; Chuchu YE ; Chuangsen FANG ; Yanming LI ; Zhongjie LI ; Weizhong YANG ; Chen WANG
Chinese Journal of Preventive Medicine 2025;59(8):1311-1319
The integration of multi-source data and the establishment of early warning indicator systems constitute pivotal elements for advancing surveillance and early warning capacities in respiratory infectious diseases. Given the multifaceted transmission mechanisms and complex contributing factors inherent in respiratory infectious diseases, surveillance datasets and associated early warning indicators demonstrate notable heterogeneity and sophisticated interrelationships. Furthermore, as surveillance and early warning requirements significantly vary across diverse epidemiological scenarios, accurate assessment of the value and applicability of distinct data types and indicators is imperative. This paper systematically reviews and synthesizes recent advancements in surveillance data and early warning indicators for respiratory infectious diseases, drawing on both domestic and international research. Particular attention is dedicated to analyzing the applicability and efficacy of various data types and indicators within multiple practical contexts, aiming to provide robust theoretical frameworks and methodological guidance to facilitate the development of resilient and efficient surveillance and early warning systems for respiratory infectious diseases.
10.Establishment and application of real-time fluorescent RAA detection method tar-getingspecific gene F57 of Mycobacterium avium subsp.paratuberculosis
Ziliang ZHAO ; Suhui ZHANG ; Jiabei HAN ; Shaomei LI ; Liu YANG ; Lizhi FU ; Kefei SHEN
Chinese Journal of Veterinary Science 2025;45(4):699-706
To rapidly and accurately detect Mycobacterium avium subsp.paratuberculosis(MAP),this study designed and screened primers and probes using its specific gene F57 as the detection target,established a recombinant enzyme-mediated isothermal amplification(RAA)fluorescence detection method,and applied this method to detect 116 clinical samples from cattle and sheep.The results showed that using the primer and probe combination B12F/B2R(0.4 μmol/L)+Probe B(0.12 μmol/L),MAP could be detected at a constant temperature of 42 ℃ within 20 min;this de-tection method had no cross-reaction with 11 common pathogens such as Escherichia coli,Clos-tridium,and bovine viral diarrhea in sheep and cattle;the lowest detection limit was 1.0×102 cop-ies/μL;the coefficient of variation was 3.77%—5.29%;24 clinical samples were positive,with a co-incidence rate of 88.89%with GBT27637-2011.In summary,this study established a fluorescent RAA detection method for MAP,which is simple,rapid,highly specific,sensitive,reproducible,and has a high coincidence rate with national standards,making it suitable for clinical detection and epi-demiological studies.

Result Analysis
Print
Save
E-mail