1.Prevention and control status of central line-associated bloodstream infection in intensive care unit in Shandong province: a cross-sectional survey analysis.
Yang SHEN ; Zijian TAI ; Xue BAI ; Xuan SONG ; Man CHEN ; Qianqian GUO ; Cheng HUAN ; Li CHEN ; Jicheng ZHANG
Chinese Critical Care Medicine 2024;36(12):1315-1320
OBJECTIVE:
To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.
METHODS:
The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.
RESULTS:
A total of 201 valid data were collected, involving 186 hospitals in the province, with a total of 201 ICU units, mainly comprehensive ICU (91%). The beds in ICU units were mainly single rooms (89%) and triple rooms (79%), and the ratio of doctors to total beds was 0.54 : 1. The training on the knowledge and operation of intravascular catheter-associated bloodstream infection in each ICU unit was mainly irregular (49%), and 96% of the catheter operators were authorized by the hospital. In terms of CVC selection, 89% of ICU units used dual-chamber CVC, and 86% of ICU units used catheters without antibiotic coating. When selecting the placement site, for conventional CVC catheterization, 65% preferred subclavian vein. Femoral vein was preferred in 87% of ICU units undergoing continuous renal replacement therapy. 95% of ICU units had established standardized operation procedure (SOP) for CVC placement. 86% of ICU units were capable of ultrasound positioning or guided puncture at the time of catheterization. During catheterization, 88% of ICU units met the sterile dress code. Before and after catheterzation, 81% and 77% of ICU units standardized hand hygiene. Only 31% of ICU units were covered from head to toe by aseptic wipes. For the choice of skin disinfectant, the majority of ICU units (72%) only used iodophor. After tube placement, 54% of ICU units chose sterile transparent dressing and 25% chose sterile gauze dressing. 98% of ICU units were sutured to secure the catheter. Regarding catheter replacement and removal, 45% of ICU units could not be removed or replaced within 2 days in emergency situations where the principle of sterility was not guaranteed. When CLABSI was suspected, 55% of ICU units were able to obtain the catheter tip, transcatheter blood culture, and contralateral peripheral vein blood culture at the same time. For CVC replacement frequency, most ICU units (75%) would not be replaced regularly, and some ICU units would be replaced regularly, but the frequency of replacement was different. For CLABSI prevention and control, 82% of ICU units developed a verification form or supervision form. When analyzing the sources of CLABSI data, most of them were filled in by themselves (60%). As for the frequency of data analysis, 57% were once a month.
CONCLUSIONS
All ICU units in Shandong Province are standardized in terms of the authorization of operators, the formulation of SOP, the formulation and implementation of verification form and supervision form, ultrasound-guided puncture, and hand hygiene before and after catheterization. However, there are still deficiencies in the training on knowledge and operation of intravascular catheter-associated bloodstream infections, maximum aseptic coverage, catheter replacement and removal, and the reporting sources of CLABSI data, which need to be strengthened in the follow-up work. At present, the selection of CVC, the selection of catheterization site, the selection of skin disinfectant and the selection of dressings after catheterization still need further research.
Intensive Care Units
;
Humans
;
Surveys and Questionnaires
;
China/epidemiology*
;
Cross-Sectional Studies
;
Catheter-Related Infections/epidemiology*
;
Catheterization, Central Venous/methods*
;
Cross Infection/epidemiology*
;
Central Venous Catheters/adverse effects*
;
Infection Control/methods*
2.Investigation on the current practice status of central venous access device maintenance among intensive care unit nurses in Shandong province
Fengzhi CHEN ; Jicheng ZHANG ; Beibei LIU ; Panpan YAO ; Yang SHEN ; Zijian TAI ; Min DING ; Congcong LIU ; Xue BAI
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2023;30(6):719-724
Objective To understand the current practice status of central venous access device(CVAD)maintenance among intensive care unit(ICU)nurses in secondary and above medical institutions in Shandong province,and to provide a basis for further implementation of effective measures to reduce the incidence of central catheter-related bloodstream infections.Methods The CVAD maintenance practice questionnaire was compiled based on domestic and international evidence related to CVAD maintenance,and a survey was conducted in October 2022 to investigate the status of ICU nurses' CVAD maintenance practice in secondary and above medical institutions in Shandong Province.Results There were 1 492 nurses participated in the survey and 1 461 valid questionnaires were recovered,with a valid recovery rate of 97.92%.The type of CVAD used by the nurses was mainly central venous catheters[92.3%(1349/1461)],and the item with the best assessment at each operation was patency of the catheter[81.1%(1185/1461)],and the worst was the patient's feeling[40.7%(594/1 461)].When assessing catheter patency,[59.8%(873/1 461)]of nurses drew back blood into the catheter.In the use of infusion connectors,three-way connectors[76.0%(1 110/1 461)]and heparin caps[62.3%(910/1 461)]were most frequently used.When sterilizing needleless connectors,most nurses could follow the correct range of disinfection,but the time of disinfection needed to be extended,and the most used items for disinfection were povidone-iodine cotton balls/swabs[44.3%(647/1 461)].The timing of changing infusion connectors needs to be standardized.Most nurses would choose saline for catheter flushing,and the number of nurses choosing saline versus heparinized saline when locking the catheter was about 50%.Most nurses can use correct size syringes and follow standardized techniques for flushing and locking.When performing CVAD maintenance,84.7%(1 237/1 461)of nurses chose a specialized care package kit.The most used skin antiseptic was povidone-iodine[63.7%(931/1 461)].Most nurses could follow the standardized range of skin disinfection,but awareness of drying needs to be improved.Dressings covering puncture points were most frequently transparent[99.7%(1 457/1 461)]and gauze[94.7%(1 383/1 461)],and the frequency of gauze dressing changes needs to be standardized.Hand hygiene and aseptic awareness of nurses during CVAD maintenance was good,but hand hygiene and the timing of wearing sterile gloves need to be standardized.Conclusions ICU nurses' CVAD maintenance practices were generally in line with the latest evidence-based recommendations,but assessment,use of maintenance-related items,and hand hygiene and aseptic technique need to be further standardized.It is recommended that nursing administrators enhance ICU nursing human resource allocation as much as possible and form a central line associated bloodstream infection(CLABSI)prevention and control management system to gradually reduce the morbidity of CLABSI within the ICU.

Result Analysis
Print
Save
E-mail