1.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Correlation of blind box consumption and non-suicidal self-injury among middle school students
LEI Lin, ZHANG Yi, HU Bin, WANG Hongyan, LUO Jinshuo, YAN Zidan, TANG Jie
Chinese Journal of School Health 2025;46(10):1392-1395
Objective:
To explore the correlation between blind box consumption and non-suicidal self-injury(NSSI) among middle school students, so as to provide new theoretical insights for the prevention of NSSI.
Methods:
Using stratified random cluster sampling method, 2 807 middle school students aged 11-19 years old were selected from Hunan and Gansu provinces from November 2024 to March 2025. The blind box consumption questionnaire and Functional Assessment of Self mutilation Scale were administered to collect data on students blind box consumption frequency, as well as NSSI behavior. The χ 2 test was used to compare differences in the distribution of NSSI across different groups. Multivariate Logistic regression analysis was performed to infer the correlation and gender differences.
Results:
A total of 15.3% of middle school students reported having at least one NSSI incident in the past year, among which the reported rates of occasional NSSI (1-4 times) and repeated NSSI (≥5 times) were 5.5% and 9.8% respectively. The results of univariate analysis showed that there was statistically significant different in NSSI distribution among groups with different blind box consumption frequencies ( χ 2=55.72, P <0.05). After adjusting for confounding factors such as age, gender, school stage, family type, discipline style, pocket money, impulsiveness and emotion management, the results of multiple Logistic regression models showed that compared with the group without blind box consumption, the risks of "occasional NSSI" and "repeated NSSI" were higher in the group with blind box consumption ( OR =1.54, 1.66), and the frequency of blind box consumption(continous variable) was positively correlated with the risks of "occasional NSSI" and "repeated NSSI" among middle school students ( OR =1.26, 1.34)(all P <0.05).After gender stratification, the consumption behavior of blind boxes and the frequency of blind box consumption (continuous variable) of boys and girls were associated with "repeated NSSI"(boys: OR =1.61, 1.32, girls: OR =1.65, 1.35), and only in the male group was a correlation between blind box consumption and "occasional NSSI" observed ( OR =2.27) (all P <0.05).
Conclusion
Blind box consumption may be related to NSSI among middle school students, and there are gender differences in its correlation with NSSI among middle school students.
7.Study on the Correlation Between Multiple Drug Resistance of Acinetobacter baumannii with Efflux Pump and Biofilm Formation
Jia WANG ; Lei FENG ; Yulei ZHENG ; Yong YUAN ; Yao YAO ; Zidan HU ; Ni SHEN ; Yan YU ; Jiawei DING
Journal of Kunming Medical University 2024;45(12):115-121
Objective To investigate the correlation between biofilm gene,efflux pump gene,biofilm forming ability and drug resistance of Acinetobacter baumarmii(AB)isolated from the patients of clinical infectious diseases.Methods A total of 119 non-repeating Acinetobacter baumannii isolates(74 MDR-AB strains and 45 non-multi-drug resistant strains)were collected.The effector pump genes(adeB,adeJ,adeG,adeS and adeR)and biofilm-related genes(bap,ompA,csuA,csuB,csuC,csuD,csuE,abaI,bfmR,bfmS)were detected by PCR.Bacterial biofilm was constructed in vitro with 24-well cell culture plates,and the formation of biofilm was qualitatively observed by crystal violet staining.Results Acinetobacter baumannii was resistant to most of the commonly used antibiotics and sensitive to tigacycline,polymyxin B and minocycline.The overall detection rate of biofilm-related genes was about 80%,and the detection rates of bap,csuB,csuC and csuD genes in multi-drug resistant bacteria were significantly higher than those in non-multi-drug resistant bacteria(P<0.05).The detection rate of active effector pump genes was less than 70%,and the detection rate of adeB,adeJ,adeS and adeR genes in multidrug-resistant bacteria was significantly higher than that in non-multidrug-resistant bacteria(P<0.05).The adeG carrying rate was opposite.Three multidrug-resistant strains and five non-multidrug-resistant strains did not carry the above efflux pump related genes,and no abeM gene was detected in all strains.The formation of biofilm was observed in 95.80%of strains.Conclusion Acinetobacter baumannii in hospital is mostly multidrug-resistant strains,most of which have strong biofilm forming ability.Multidrug-resistant bacteria have higher biofilm gene and effluent-pump gene carrying rate,which may be involved in the regulation and formation of multidrug resistance.
8. Determination of N-methyl-2-pyrrolidone in workplace air by solvent desorption-gas chromatography
Ruibo MENG ; Weifeng RONG ; Jiawen HU ; Jiaheng HE ; Zidan YAN ; Yuanyuan SHE ; Banghua WU
China Occupational Medicine 2019;46(02):229-232
OBJECTIVE: To establish a method for determination of N-methyl-2-pyrrolidone(NMP) in workplace air by solvent desorption-gas chromatography. METHODS: NMP in the workplace air was collected with activated carbon tube and desorbed with methanol ∶dichloromethane(5 ∶95, V/V). After desorption, it was separated by capillary column separation, and detected by flame ionization detector. RESULTS: The good linear concentration of NMP was 0.51-4 108.00 mg/L. The correlation coefficient was 0.999 9. The detection limit was 0.08 mg/L(calculated by 3 times of standard deviation). The average desorption efficiency was 101.68%-103.44%. The within-run and between-run relative standard deviations were 1.94%-3.97% and 0.97%-2.26%, respectively. The sample could be stored at room temperature for at least 14 days. CONCLUSION: The developed method is suitable for the determination of NMP in workplace air.


Result Analysis
Print
Save
E-mail