1.Associations between statins and all-cause mortality and cardiovascular events among peritoneal dialysis patients: A multi-center large-scale cohort study.
Shuang GAO ; Lei NAN ; Xinqiu LI ; Shaomei LI ; Huaying PEI ; Jinghong ZHAO ; Ying ZHANG ; Zibo XIONG ; Yumei LIAO ; Ying LI ; Qiongzhen LIN ; Wenbo HU ; Yulin LI ; Liping DUAN ; Zhaoxia ZHENG ; Gang FU ; Shanshan GUO ; Beiru ZHANG ; Rui YU ; Fuyun SUN ; Xiaoying MA ; Li HAO ; Guiling LIU ; Zhanzheng ZHAO ; Jing XIAO ; Yulan SHEN ; Yong ZHANG ; Xuanyi DU ; Tianrong JI ; Yingli YUE ; Shanshan CHEN ; Zhigang MA ; Yingping LI ; Li ZUO ; Huiping ZHAO ; Xianchao ZHANG ; Xuejian WANG ; Yirong LIU ; Xinying GAO ; Xiaoli CHEN ; Hongyi LI ; Shutong DU ; Cui ZHAO ; Zhonggao XU ; Li ZHANG ; Hongyu CHEN ; Li LI ; Lihua WANG ; Yan YAN ; Yingchun MA ; Yuanyuan WEI ; Jingwei ZHOU ; Yan LI ; Caili WANG ; Jie DONG
Chinese Medical Journal 2025;138(21):2856-2858
2.Research progress on the manufacturing technology of hollow microneedles.
Shengshuo ZHOU ; Huajian ZHOU ; Xiaoyu DU ; Ziye YU ; Tongle XU ; Shun ZHAO ; Peiqiang SU ; Leian ZHANG ; Guangyang FU ; Xuelei LIU
Journal of Biomedical Engineering 2025;42(2):423-430
Drug administration via hollow microneedles (HMN) have the advantages of painlessness, avoidance of first-pass effect, capability of sustained infusion, and no need for professional personnel operation. In addition, HMN can also be applied in the fields of body fluid extraction and biosensors, showing broad application prospects. However, traditional manufacturing technologies cannot meet the demand for low-cost mass production of HMN, limiting its widespread application. This paper reviews the main manufacturing technologies used for HMN in recent years, which include photolithography and etching, laser etching, sputtering and electroplating, micro-molding, three-dimensional (3D) printing and drawing lithography. It further analyzes the characteristics and limitations of existing manufacturing technologies and points out that the combination of various manufacturing technologies can improve production efficiency to a certain extent. In addition, this paper looks forward to the future trends of HMN manufacturing technology and proposes possible directions for its development. In conclusion, it is expected that this review can provide new ideas and references for follow-up research.
Printing, Three-Dimensional
;
Needles
;
Humans
;
Drug Delivery Systems/methods*
;
Equipment Design
;
Microinjections/methods*
3.Clinical study on reduction of posterior malleolar fractures via modified Rammelt transfibular approach.
Shaozhen JI ; Jianyi LEI ; Jianbo GUO ; Dehang LIU ; Xiangliang GE ; Jinxi HU ; Shixin LIU ; Zhenhui SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1441-1446
OBJECTIVE:
To evaluate the safety and effectiveness of reducing posterior malleolar fractures via the modified Rammelt transfibular approach.
METHODS:
A retrospective analysis was conducted on 26 patients with ankle fractures who met the selection criteria and were admitted between September 2023 and May 2024. There were 13 males and 13 females, aged from 14 to 59 years (median, 43.5 years). Causes of injury included traffic accident (1 case), falls (7 cases), and sprains (18 cases). Time from injury to operation ranged from 1 to 13 days (mean, 3.9 days). According to the Lauge-Hansen classification, there were 5 supination-external rotation type Ⅲ fractures and 21 supination-external rotation type Ⅳ fractures. According to the Bartoníček classification for posterior malleolar fractures, there were 12 type Ⅱ fractures, 10 type Ⅲ fractures, and 4 type Ⅳ fractures. During operation, the fracture was exposed via the modified Rammelt transfibular approach; then, the fracture reduction was achieved under direct vision using techniques such as towel clip traction, posterolateral compression, and lifting with a posterior transverse periosteal elevator; finally, the fracture was fixed using anteroposterior cannulated screws or Kirschner wires. The incision healing was observed after operation. At 4 months after operation, X-ray film and CT were reviewed to evaluate the quality of fracture reduction. The medial clear space, tibiofibular clear space, and the anterior/posterior tibiofibular syndesmotic distances were measured. At last follow-up, the ankle function was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) score and the range of motion.
RESULTS:
The marginal necrosis occurred in 2 lateral malleolar incisions, and superficial infection occurred in 1 lateral malleolar incision; the remaining incisions healed by first intention. All 26 patients were followed up 13-21 months (mean, 15.6 months). X-ray films showed that fractures in 25 patients achieved clinical union within 3-8 months (mean, 5.4 months); 1 case had delayed union of the lateral malleolus. At 4 months after operation, no significant difference was found between the injured and healthy sides in the medial clear space, tibiofibular clear space, or the anterior/posterior tibiofibular syndesmotic distances ( P>0.05). No malreduction of the posterior malleolus or the tibiofibular syndesmosis occurred. At last follow-up, the AOFAS score ranged from 80 to 100 (mean, 91.9). The range of motion ranged from 17° to 22° (mean, 21.0°) in active ankle dorsiflexion and from 40° to 49° (mean, 44.6°) in plantar flexion. Internal fixator was removed in 12 patients at 1 year after operation, with no ankle instability occurring. Ankle joint degeneration was observed in 1 patient at last follow-up.
CONCLUSION
The modified Rammelt transfibular approach is a safe and reliable technique. It enables precise reduction under direct vision, improves the quality of reduction for the distal tibial articular surface and the tibiofibular syndesmosis, and provides satisfactory ankle functional recovery in short-term follow-up.
Humans
;
Male
;
Female
;
Adult
;
Ankle Fractures/diagnostic imaging*
;
Middle Aged
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Adolescent
;
Treatment Outcome
;
Young Adult
;
Bone Screws
;
Ankle Joint/surgery*
;
Fibula/surgery*
;
Range of Motion, Articular
4.Risk Factors of Depression Screened by Two-Sample Mendelian Randomization Analysis: A Systematic Review
Lin Han WANG ; Feng Yan XUE ; Qiu Bao CUI ; Hong LIU ; Xin Xin SHEN
Biomedical and Environmental Sciences 2024;37(1):85-95
Objective This study explored the potentially modifiable factors for depression and major depressive disorder (MDD) from the MR-Base database and further evaluated the associations between drug targets with MDD.Methods We analyzed two-sample of Mendelian randomization (2SMR) using genetic variant depression (n = 113,154) and MDD (n = 208,811) from Genome-Wide Association Studies (GWAS). Separate calculations were performed with modifiable risk factors from MR-Base for 1,001 genomes. The MR analysis was performed by screening drug targets with MDD in the DrugBank database to explore the therapeutic targets for MDD. Inverse variance weighted (IVW), fixed-effect inverse variance weighted (FE-IVW), MR-Egger, weighted median, and weighted mode were used for complementary calculation.Results The potential causal relationship between modifiable risk factors and depression contained 459 results for depression and 424 for MDD. Also, the associations between drug targets and MDD showed that SLC6A4, GRIN2A, GRIN2C, SCN10A, and IL1B expression are associated with an increased risk of depression. In contrast, ADRB1, CHRNA3, HTR3A, GSTP1, and GABRG2 genes are candidate protective factors against depression.Conclusion This study identified the risk factors causally associated with depression and MDD, and estimated 10 drug targets with significant impact on MDD, providing essential information for formulating strategies to prevent and treat depression.
5.Diagnostic value of MR high resolution imaging of vascular wall on vertebrobasilar artery tortuous prolongation complicated by multiple cerebral infarction in posterior circulation
Yue LI ; Zaili YANG ; Bing LIU ; Zibo BAI
China Medical Equipment 2024;21(8):42-45,59
Objective:To explore the diagnostic value of magnetic resonance(MR)high-resolution imaging of vascular wall on vertebrobasilar artery tortuosity prolongation complicated by multiple cerebral infarction in posterior circulation.Methods:Regression analysis was used in this research.A total of 138 patients with vertebrobasilar artery tortuosity prolongation who admitted to Hengshui City People′s Hospital from January 2020 to January 2023 were selected.Among of them,54 patients who complicated with multiple cerebral infarction in posterior circulation were divided into the occurrence group,and 84 patients without multiple cerebral infarction in posterior circulation were divided into the non-occurrence group.All patients underwent high-resolution MR imaging of vascular wall,and the basilar artery(BA),hemodynamic indicators such as systolic peak(Vs),average peak(Vd),diastolic peak flow velocity(Vm),pulsatile index(PI),blood flow resistance index(RI),as well as intracranial responsibility plaque characteristics and vertebral basilar artery grading between two groups were compared.Results:The Vs,Vd,Vm,PI and RI indicators of patients in the non-occurrence group were significantly higher than those in the occurrence group,and the differences were statistically significant(t=11.742,4.323,7.367,4.824,2.351,P<0.05),respectively.The degree(60.31±4.24)%of intracranial plaque stenosis in the non-occurrence group was significantly lower than(73.67±5.96)%in the occurrence group,and the difference was statistically significant(t=15.376,P<0.05).There were no statistically significant differences in plaque area,plaque load,arterial remodeling index and eccentricity index between the two groups(P>0.05).The height level of vertebral basilar artery bifurcation and the degree of vertebral basilar artery deviation in the non-occurrence group were significantly lower than those in the occurrence group,with statistically significant differences(x2=3.907,6.419,P<0.05).Conclusion:MR high-resolution imaging of vascular wall can clearly display the blood flow velocity and intracranial plaque situation in patients with vertebrobasilar artery tortuosity prolongation,and conduct the grade for the vertebrobasilar artery,which has significant application value in predicting the occurrence of vertebrobasilar artery tortuosity prolongation complicated by multiple cerebral infarction in posterior circulation.
6.Progress in the diagnosis and treatment of dedifferentiated chondrosarcoma
Zibo XU ; Zhuoyu LI ; Weifeng LIU
Chinese Journal of Orthopaedics 2024;44(20):1371-1376
Dedifferentiated chondrosarcoma (DDCS) is a rare, high-grade variant of chondrosarcoma with a poor prognosis, making its diagnosis and treatment particularly challenging. Comprehensive imaging plays a crucial role in the initial diagnosis, while image-guided biopsy remains an essential tool for confirming the disease. Surgical intervention remains the primary treatment modality, and selecting an appropriate surgical approach based on the patient's condition is critical. Achieving wide or radical surgical margins is vital for reducing the risk of local recurrence and distant metastasis. Unfortunately, DDCS demonstrates limited sensitivity to both radiotherapy and chemotherapy, and current advancements in these therapeutic approaches remain in the exploratory phase. In recent years, efforts by both domestic and international researchers to incorporate novel therapies such as immunotherapy and targeted therapy have yielded promising, results. Given the rarity of DDCS, existing clinical studies are largely limited to case reports or small retrospective studies, highlighting the need for larger, more robust studies to strengthen the evidence base. This review aims to summarize the latest progress in the diagnosis and treatment of DDCS, offering insights to guide clinical practice and inform future research directions.
7.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail