1.Research on The Genealogical Inference Efficiency of High-density SNPs
Jing LI ; Yi-Jie SUN ; Wen-Ting ZHAO ; Zi-Chen TANG ; Jing LIU ; Cai-Xia LI
Progress in Biochemistry and Biophysics 2026;53(3):740-753
ObjectiveThis study aims to explore the potential of different orders of magnitude single-nucleotide polymorphism (SNP) locus combinations for predicting distant kinship relationships. A high-density SNP locus set was constructed, and a comprehensive assessment of its inference capability was conducted. MethodsFirstly, we selected three commercial chip panels, CGA (Chinese genotyping array, Illumina), GSA (Global screening array, Illumina), Affy (23MF_V2 high-density SNP array, Affymetrix) and merged them after quality control, forming a high-density SNP locus panel(1 180 k). Secondly, we selected 161 samples and collected their peripheral blood samples by using whole-genome sequencing technology. Within this sample population, the levels of kinship relationships fully covered the range from level 1 to level 9, and the number of kinship pairs at each level was consistently maintained at over 50 pairs. From 161 samples data of whole-genome sequencing, the 1 180 k locus set was extracted, which is referred to as the high-density SNP locus set in the following text. The kinship inference was conducted using the identity-by-descent (IBD) algorithm with the selected optimal parameters. To comprehensively evaluate the performance of the high-density SNP locus set in kinship inference, we compared it with the three commercial chip panels, the intersection of these three chip loci, and the control sets constructed by randomly reducing the number of the high-density SNP locus set. Based on the changes in the IBD lengths, as well as the dynamic trends in prediction accuracy, we conducted a scientific assessment of the kinship inference capability of the high-density SNP locus set. ResultsAfter screening, a set of 1 184 334 autosomal SNPs was obtained. During the process of screening the optimal IBD length threshold, the result revealed that 0 cM, 1 cM, and 2 cM all demonstrated good applicability. However, to avoid the issue of a large amount of redundant information caused by setting a too low IBD length threshold, this study ultimately selected 2 cM as the optimal threshold. Compared with the average results of three chip panels, the high-density SNP locus set increased the total IBD length and the average IBD length across levels 1-9; the accuracy of the confidence interval for level 8 was 70.97%, which represented a 3.50% improvement; the average confidence interval accuracy for levels 1-8 was 91.39%, representing a 1.00% increase; and the false negative rates at levels 8 and 9 were reduced by 2.42% and 6.76%, respectively. The system efficacy of the high-density SNP locus set for kinship inference of first to eighth degree relationships reached 98.91%. Through random reduction of the high-density SNP locus set results, it is found that increasing the number of SNPs with the panel, the detection efficiency of IBD length showed a significant upward trend. At the same time, the overall trend in the accuracy of kinship relationship prediction as well as the confidence interval accuracy also indicated that both metrics steadily increased with the addition of more loci. ConclusionThe results show that the high-density SNPs panel significantly enhances the efficacy of distant kinship inference, accurately covering kinship degrees, with the average confidence interval accuracy for first to eighth degree relationships stably above 90%. The study finds that increasing the number of SNPs panel can improve the ability to predict distant kinship.
2.Insights on Peripheral Blood Biomarkers for Parkinson’s Disease
Yu-Meng LI ; Jing-Kai LIU ; Zi-Xuan CHEN ; Yu-Lin DENG
Progress in Biochemistry and Biophysics 2025;52(1):72-87
Parkinson’s disease (PD) is a common neurodegenerative disorder with profound impact on patients’ quality of life and long-term health, and early detection and intervention are particularly critical. In recent years, the search for precise and reliable biomarkers has become one of the key strategies to effectively address the clinical challenges of PD. In this paper, we systematically evaluated potential biomarkers, including proteins, metabolites, epigenetic markers, and exosomes, in the peripheral blood of PD patients. Protein markers are one of the main directions of biomarker research in PD. In particular, α‑synuclein and its phosphorylated form play a key role in the pathological process of PD. It has been shown that aggregation of α-synuclein may be associated with pathologic protein deposition in PD and may be a potential marker for early diagnosis of PD. In terms of metabolites, uric acid, as a metabolite, plays an important role in oxidative stress and neuroprotection in PD. It has been found that changes in uric acid levels may be associated with the onset and progression of PD, showing its potential as an early diagnostic marker. Epigenetic markers, such as DNA methylation modifications and miRNAs, have also attracted much attention in Parkinson’s disease research. Changes in these markers may affect the expression of PD-related genes and have an important impact on the onset and progression of the disease, providing new research perspectives for the early diagnosis of PD. In addition, exosomes, as a potential biomarker carrier for PD, are able to carry a variety of biomolecules involved in intercellular communication and pathological regulation. Studies have shown that exosomes may play an important role in the pathogenesis of PD, and their detection in blood may provide a new breakthrough for early diagnosis. It has been shown that exosomes may play an important role in the pathogenesis of PD, and their detection in blood may provide new breakthroughs in early diagnosis. In summary, through in-depth evaluation of biomarkers in the peripheral blood of PD patients, this paper demonstrates the important potential of these markers in the early diagnosis of PD and in the study of pathological mechanisms. Future studies will continue to explore the clinical application value of these biomarkers to promote the early detection of PD and individualized treatment strategies.
3.Advances in DNA methylation of brain-derived neurotrophic factor and depression
Zi-yun LIAO ; Meng-yu WANG ; Jing-yi QIAO ; Run ZHANG ; Pei-dong LIU ; Xin-wang CHEN
Chinese Pharmacological Bulletin 2025;41(5):825-829
Depression is a heterogeneous mental disorder in which the interaction between genetic susceptibility and environ-mental factors plays a key role in its pathogenesis.Although the specific mechanisms of the disease still need to be thoroughly studied and elucidated,there is now a broad consensus that epi-genetic markers have a central influence on its mechanism of ac-tion.DNA methylation of brain-derived neurotrophic factor(BD-NF)is not only regarded as a promising epigenetic biomarker of pathology,but may also help predict the efficacy of antidepres-sants.In this paper we reviewed the gene structure of BDNF and its DNA methylation regulation mechanism,and also analyzed the changes of DNA methylation of this factor in depression pa-tients and animal models,aiming to provide new ideas and theo-retical support for clinical research.
4.Comparison of active constituent contents and their biological activities of Buzhong Yiqi Recipe with different dosage forms
Yan-ran HE ; Jing WANG ; Jia-qiang XU ; Zhao-zhao XIA ; Ying-jiao LIU ; Zi-shu DONG ; Liang-shan MING ; Hong-ning LIU ; Qi-meng FAN
Chinese Traditional Patent Medicine 2025;47(2):357-364
AIM To compare total sugar,total protein,total phenol,total flavonoid,calycosin-7-O-β-D-glucoside,liquiritin,lobetyolin,quercetin,isoferulic acid,hesperidin,glycyrrhizic acid contents and their antioxidant activities,hypoglycemic activities of big honey pill,small honey pill,water pill,concentrated pill,granule,mixture and decoction of Buzhong Yiqi Recipe.METHODS Anthraquinone-sulfuric acid method,Coomassie brilliant blue method,Folin-phenol colorimetry method,sodium nitrite-aluminum nitrate method and HPLC were adopted in the content determination of total sugar,total protein,total phenol,total flavonoid and seven constituents,respectively,after which the scavenging capacities,reducing powers on DPPH·free radical,ABTS+free radical,hydroxyl free radical,and inhibition capacity on α-glucosidase activity were detected.Subsequently,correlation analysis was performed.RESULTS Total sugar,total protein,total phenol and total flavonoid contents demonstrated significant differences among different dosage forms(P<0.05,P<0.01).Calycosin-7-O-β-D-glucoside,glycyrrhizin,codonoside and quercetin displayed the highest contents in the decoction,while those of isoferulic acid,hesperidin and glycyrrhizin were observable in the mixture.The water pill exhibited the strongest antioxidant activity,while those of the concentrated pill and mixture were weak;the big honey pill exhibited the strongest hypoglycemic activity,while that of the decoction was the weakest.Total protein,total phenol,total flavonoid and liquiritin contents displayed significant positive correlations between antioxidant activity(P<0.05,P<0.01),while hesperidin content displayed significant negative correlation between the latter(P<0.05);total protein,calycosin-7-O-β-D-glucoside,codonoside and quercetin contents displayed significant negative correlations between hypoglycemic activity(P<0.05,P<0.01).CONCLUSION Active constituent contents and their biological activities of Buzhong Yiqi Recipe with different dosage forms exist differences,total sugar,total protein,total flavonoids,calycosin-7-O-β-D-glucoside,licorice glycoside,hesperidin,codonoside and quercetin can be taken as quality control indices for this prescription.
5.Study on the Genotoxicity of Graphene Artificial Nerve Sheath Conduit
Ling-xiao SUN ; Bing-bing SUN ; Yue QIN ; Guo-wei WANG ; Luan-luan WANG ; Zi-yi YANG ; Zi-ye WANG ; Xiao-tian ZHAO ; Xiao-jing LI ; Cheng-hu LIU
Progress in Modern Biomedicine 2025;25(14):2250-2258
Objective:The genotoxicity risk of graphene artificial nerve sheath conduit was systematically evaluated to provide scientific evidence for their clinical safety and to establish methodological references for the genotoxicity assessment of nanomaterial medical devices.Methods:The potential effects of graphene artificial nerve sheath conduit on genetic and chromosomal endpoints were analyzed by integrating bacterial reverse mutation assays,in vitro chromosome aberration assays,mouse lymphoma cell TK gene mutation tests,and mammalian erythrocyte Pig-a gene mutation assays.Results:In the bacterial reverse mutation assay,all plates showed good background growth.There was no significant difference in the average number of revertant colonies between the test group and the negative control group,with a ratio around 1.0.In the in vitro chromosome aberration assay,the chromosomal aberration rate in the test group was less than 5%,showing no significant increase compared to the negative control group.In the mouse lymphoma cell TK gene mutation assay,the mutation frequency in the test group was less than twice that of the negative control group,with no significant difference.In the mammalian erythrocyte Pig-a gene mutation assay,the mutation frequencies of erythrocytes and reticulocytes in the test group were both less than 3× 10-6,showing no significant difference compared to the negative control group.Conclusions:Graphene artificial nerve sheath conduit exhibited no detectable genotoxicity under the tested conditions,the research results can provide reference and guidance for the genotoxicity evaluation of nanomaterial medical devices.
6.Epidemiological and molecular traceability analysis of the first cluster outbreak of D8 genotype measles in Henan Province
Xiaoxiao ZHANG ; Binghui DU ; Daxing FENG ; Wenhui WANG ; Jing LI ; Lili LIU ; Hui ZI ; Qihua WAN ; Songtao ZHAO ; Xiaoli WANG ; Xiaobo WU ; Yonghao GUO ; Yanyang ZHANG ; Dongyang ZHAO
Chinese Journal of Preventive Medicine 2025;59(8):1294-1298
In February 2025, a local cluster outbreak caused by the D8 genotype Measles virus (MV) was first discovered in Henan Province. Epidemiological investigations and laboratory testing were conducted, including the collection of serum and throat swabs for MV IgM antibody and nucleic acid detection, virus isolation and genetic homology analysis. Measures such as close contact tracing, vaccination rate assessment and supplementary immunization activities were implemented, successfully preventing broader community transmission. A total of three cases were reported during the outbreak, including one imported-related adolescent and two secondary local adult cases. All cases presented with typical symptoms such as fever and rash. Both adult cases were complicated by pneumonia, with one case developing into severe pneumonia. MV genotyping showed that the two secondary cases were both the D8 genotype, with the viral sequences being completely homologous to the Kazakhstan strain. Among the close contacts, 98.2% were adults, and 142 individuals received emergency vaccination.
7.Advances in DNA methylation of brain-derived neurotrophic factor and depression
Zi-yun LIAO ; Meng-yu WANG ; Jing-yi QIAO ; Run ZHANG ; Pei-dong LIU ; Xin-wang CHEN
Chinese Pharmacological Bulletin 2025;41(5):825-829
Depression is a heterogeneous mental disorder in which the interaction between genetic susceptibility and environ-mental factors plays a key role in its pathogenesis.Although the specific mechanisms of the disease still need to be thoroughly studied and elucidated,there is now a broad consensus that epi-genetic markers have a central influence on its mechanism of ac-tion.DNA methylation of brain-derived neurotrophic factor(BD-NF)is not only regarded as a promising epigenetic biomarker of pathology,but may also help predict the efficacy of antidepres-sants.In this paper we reviewed the gene structure of BDNF and its DNA methylation regulation mechanism,and also analyzed the changes of DNA methylation of this factor in depression pa-tients and animal models,aiming to provide new ideas and theo-retical support for clinical research.
8.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
9.Determination of contezolid in human cerebro spinal fluid by UPLC-MS/MS
Ju-ping YUN ; Zi-he WANG ; Wen-jing WANG ; Wei LIU
The Chinese Journal of Clinical Pharmacology 2025;41(1):91-95
Objective To establish a method for determining the concentration of contezolid in human cerebro spinal fluid(CSF)using ultra high performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS).Methods Linezolid as the internal standard(IS)and acetonitrile as the protein precipitant.Waters ACQUITY UPLC? BEH C18(2.1 mm × 50.0 mm,1.7 μm)chromatographic column was used for separation,with a mobile phase of 0.1%formic acid aqueous solution-0.1%formic acid acetonitrile solution,gradient elution method,flow rate was 0.4 mL·min-1,column temperature was 40 ℃,automatic sampler temperature was 10 ℃,the analysis time was 4 minutes.Electrospray ion source,positive ion mode,and multi-reaction monitoring scanning mode were used.The monitoring and analysis ion pairs for contezolid were m/z 409.15→269.14,and the monitoring ion pairs for linezolid were m/z 338.14 → 195.10.The specificity,standard curve and lower limit of quantification(LLOQ),precision and recovery rate,matrix effect,residual effect,dilution effect and stability of the method were investigated.Results The endogenous substances in CSF do not interfere with the determination of the analyte contezolid and the internal standard linezolid,and the method has good specificity.Satisfactory linearity was observed within the concentration range of 20-5 000 ng·mL-1 for contezolid in CSF,the calibration curve was y=8.97 × 10-4x+1.95 × 10-2(r=0.999 1),and the LLOQ was 20 ng·mL-1.Precision of the intra-batch and inter-batch relative standard deviation(RSD)<15%,and the extraction recovery were 90.96%-98.71%.The average normalized matrix effect factor of the quality control CSF sample were 94.39%-100.25%.The RSD of dilution effect<15%.The CSF samples of contezolid were stored at room temperature,in the automatic sampler for 72 hours,-20 ℃ and-80 ℃ for 90 days,and subjected to repeated freezing and thawing three times,were stable with all of which the RSD<10%.Conclusion This method is high sensitivity,rapid,simple and accurate,which is very suitable for the therapeutic drug monitoring of contezolid in human CSF.
10.EEG phase prediction method based on long short-term memory network
Zi-yan PANG ; Xin-yu ZHAO ; Wen-shu MAI ; Yue-zhuo ZHAO ; Zhi-peng LIU ; Tao YIN ; Jing-na JIN
Chinese Medical Equipment Journal 2025;46(3):1-8
Objective To propose a brain electrical phase prediction method based on long short-term memory network(LSTM)to improve the accuracy and robustness of phase synchronization prediction in transcranial magnetic stimulation(TMS).Methods First,an LSTM consisting of an input layer,an LSTM layer,an ReLU activation layer,a fully connected layer and a regression layer was constructed to capture the EEG signal features through the synergistic action of input gates,forgetting gates and output gates.Second,eye-open resting-state EEG data from 30 healthy subjects were trained using the LSTM to obtain a predictive model for EEG signal and EEG phase prediction.Finally,the LSTM method and the traditional autoregressive(AR)method were compared in terms of the phase prediction errors at the overall and individual levels and the prediction performance for peaks and troughs.A regression model was used to explore the relationships between instantaneous EEG amplitude,signal-to-noise ratio and phase prediction error with the LSTM method.Results The LSTM method achieved a total phase prediction error of 0.04°±5.69°,which was lower than that of the traditional AR method(-3.36°±51.13°).For each subject,the LSTM method demonstrated superior phase prediction accuracy compared to the traditional AR method(P<0.001).The accuracy for predicting peaks(troughs)by the LSTM method(about 89%)was higher than that by the traditional AR method(about 10%).Unlike the traditional AR method,the LSTM method didnot result in linear relationships between instantaneous EEG amplitude,signal-to-noise ratio and phase prediction error,with Pvalues being 0.58 and 0.18,respectively.Conclusion The LSTM-based brain electrical phase prediction method shows high accuracy and robustness when used for EEG phase-synchronized TMS.[Chinese Medical Equipment Journal,2025,46(3):1-8]

Result Analysis
Print
Save
E-mail