1.Clinical research on the combination therapy of vericiguat and metoprolol in the treatment of heart failure with reduced ejection fraction
Dandan LIU ; Zhuoqun HE ; Dan KOU
China Pharmacy 2026;37(15):2030-2034
OBJECTIVE To study the efficacy and safety of the combination therapy of vericiguat and metoprolol in the treatment of heart failure with reduced ejection fraction (HFrEF). METHODS Prospective inclusion of 136 HFrEF patients admitted to the Handan First Hospital from January 2022 to January 2025, divided into a control group and an experimental group using a random number table method, 68 cases per group. At the same time as anti heart failure foundation, the control group was treated with metoprolol, while the experimental group was treated with metoprolol and vericiguat for 6 months. Compare the clinical efficacy and cardiac function indicators, serological related indicators, quality of life before and after treatment, and incidence of adverse reactions between the two groups. RESULTS Three cases were lost in the experimental group and four cases were lost in the control group. The total clinical effective rate of the experimental group was 95.38%, significantly higher than the control group’s 75.00% (P<0.05). Compared to before treatment, after treatment, the left ventricular end-systolic diameter, left ventricular end-diastolic diameter, homocysteine level, N-terminal pro-B-type natriuretic peptide level, C-reactive protein level, and Minnesota Living with Heart Failure Questionnaire scores of both groups of patients significantly decreased (P<0.05), while the left ventricular ejection fraction significantly increased (P<0.05), and the improvement effect of the experimental group was more significant than that of the control group (P<0.05). There was no statistically significant difference in the incidence of adverse reactions between the two groups of patients (P>0.05). CONCLUSIONS Compared to metoprolol alone, the combination of vericiguat and metoprolol can further improve heart function in HFrEF patients, better regulate serological related indicators, enhance quality of life and overall clinical efficacy, and has good safety.
2.Effect of minimally invasive interbody fusion device height on lumbar biomechanics in patients with adolescent lumbar disc herniation
Ruofan ZHANG ; Huanhuan GUAN ; Zhuoqun HE ; Yunfeng ZHANG ; Feng JIN ; Zhiqiang WANG ; Jianzhong WANG ; Xiaohe LI ; Yong ZHU ; Haiyan WANG ; Kai ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(21):4421-4429
BACKGROUND:Adolescent lumbar disc herniation is the main cause of low back pain in adolescents. At present,most of them are treated by conservativetreatment. When long-term non-surgical treatment attempts,surgery may be necessary to prevent further injury when the patient's symptoms are notsufficiently relieved or when the patient has symptoms of single nerve paralysis or compression of the cauda equina,it is very important to choose a suitable interbody fusion device for the surgical treatment of the patients.OBJECTIVE:To explore the effects of minimally invasive interbody fusion with different heights on lumbar biomechanics in patients with adolescent lumbar disc herniation.METHODS:CT scans of a 17-year-old male patient with adolescent lumbar disc herniation (L4-5 segment herniation) were collected. After the three-dimensional reconstruction of MIMICS,the interbody fusion device equal to and 3 mm higher than the intervertebral space was selected for analysis,so two expandablemixed material interbody fusion devices were designed and reconstructed. Fusion device L:11 mm high front,9 mm high posterior,9 mm wide,28 mmlong,and fusion device H:14 mm high front,11 mm high posterior,11 mm wide,28 mm long and the lumbar fusion device was modeled. The fusion deviceand lumbar spine model were optimized,inversely modeled,and then imported into ABAQUS,and finally the 3D model of lumbar fusion was obtained.The physiological activities of the human body were simulated,such as lumbar extension,forward bending,right bending,and left bending,to obtain thecorresponding stress contours. The biomechanical characteristics of the L4-5 vertebra under seven different working conditions were observed.RESULTS AND CONCLUSION:(1) The maximum stress of the two kinds of fuses was in the condition of forward bending and backward extension,the stress value of H fuses was (18.27±3.80) Mpa and (15.02±3.24) Mpa;the stress value of L fuses was (9.16±0.05) Mpa and (9.17±1.83) Mpa. The stress values of the end plate of the H-fusion in the extension station were (19.11±4.03) Mpa and (16.32±3.72) Mpa respectively. The stress values of the L-fusion end plate were (9.13±0.01) Mpa and (4.92±1.01) Mpa respectively. (2) The stress of H-type fusing end plate was higher than that of L-type fusing end plate except for L-5 end plate at neutral position (P<0.05). (3) Choosing an interbody fusion device with a height of more than 3 mm in the same intervertebral space has a more stable biomechanics.
3.Effect of minimally invasive interbody fusion device height on lumbar biomechanics in patients with adolescent lumbar disc herniation
Ruofan ZHANG ; Huanhuan GUAN ; Zhuoqun HE ; Yunfeng ZHANG ; Feng JIN ; Zhiqiang WANG ; Jianzhong WANG ; Xiaohe LI ; Yong ZHU ; Haiyan WANG ; Kai ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(21):4421-4429
BACKGROUND:Adolescent lumbar disc herniation is the main cause of low back pain in adolescents. At present,most of them are treated by conservativetreatment. When long-term non-surgical treatment attempts,surgery may be necessary to prevent further injury when the patient's symptoms are notsufficiently relieved or when the patient has symptoms of single nerve paralysis or compression of the cauda equina,it is very important to choose a suitable interbody fusion device for the surgical treatment of the patients.OBJECTIVE:To explore the effects of minimally invasive interbody fusion with different heights on lumbar biomechanics in patients with adolescent lumbar disc herniation.METHODS:CT scans of a 17-year-old male patient with adolescent lumbar disc herniation (L4-5 segment herniation) were collected. After the three-dimensional reconstruction of MIMICS,the interbody fusion device equal to and 3 mm higher than the intervertebral space was selected for analysis,so two expandablemixed material interbody fusion devices were designed and reconstructed. Fusion device L:11 mm high front,9 mm high posterior,9 mm wide,28 mmlong,and fusion device H:14 mm high front,11 mm high posterior,11 mm wide,28 mm long and the lumbar fusion device was modeled. The fusion deviceand lumbar spine model were optimized,inversely modeled,and then imported into ABAQUS,and finally the 3D model of lumbar fusion was obtained.The physiological activities of the human body were simulated,such as lumbar extension,forward bending,right bending,and left bending,to obtain thecorresponding stress contours. The biomechanical characteristics of the L4-5 vertebra under seven different working conditions were observed.RESULTS AND CONCLUSION:(1) The maximum stress of the two kinds of fuses was in the condition of forward bending and backward extension,the stress value of H fuses was (18.27±3.80) Mpa and (15.02±3.24) Mpa;the stress value of L fuses was (9.16±0.05) Mpa and (9.17±1.83) Mpa. The stress values of the end plate of the H-fusion in the extension station were (19.11±4.03) Mpa and (16.32±3.72) Mpa respectively. The stress values of the L-fusion end plate were (9.13±0.01) Mpa and (4.92±1.01) Mpa respectively. (2) The stress of H-type fusing end plate was higher than that of L-type fusing end plate except for L-5 end plate at neutral position (P<0.05). (3) Choosing an interbody fusion device with a height of more than 3 mm in the same intervertebral space has a more stable biomechanics.

Result Analysis
Print
Save
E-mail