1.Expert consensus on peri-implant keratinized mucosa augmentation at second-stage surgery.
Shiwen ZHANG ; Rui SHENG ; Zhen FAN ; Fang WANG ; Ping DI ; Junyu SHI ; Duohong ZOU ; Dehua LI ; Yufeng ZHANG ; Zhuofan CHEN ; Guoli YANG ; Wei GENG ; Lin WANG ; Jian ZHANG ; Yuanding HUANG ; Baohong ZHAO ; Chunbo TANG ; Dong WU ; Shulan XU ; Cheng YANG ; Yongbin MOU ; Jiacai HE ; Xingmei YANG ; Zhen TAN ; Xiaoxiao CAI ; Jiang CHEN ; Hongchang LAI ; Zuolin WANG ; Quan YUAN
International Journal of Oral Science 2025;17(1):51-51
Peri-implant keratinized mucosa (PIKM) augmentation refers to surgical procedures aimed at increasing the width of PIKM. Consensus reports emphasize the necessity of maintaining a minimum width of PIKM to ensure long-term peri-implant health. Currently, several surgical techniques have been validated for their effectiveness in increasing PIKM. However, the selection and application of PIKM augmentation methods may present challenges for dental practitioners due to heterogeneity in surgical techniques, variations in clinical scenarios, and anatomical differences. Therefore, clear guidelines and considerations for PIKM augmentation are needed. This expert consensus focuses on the commonly employed surgical techniques for PIKM augmentation and the factors influencing their selection at second-stage surgery. It aims to establish a standardized framework for assessing, planning, and executing PIKM augmentation procedures, with the goal of offering evidence-based guidance to enhance the predictability and success of PIKM augmentation.
Humans
;
Consensus
;
Dental Implants
;
Mouth Mucosa/surgery*
;
Keratins
2.Research on Logic Design of Proton Treatment Control System.
Zhuofan CAI ; Rong XIE ; Jianchun DENG ; Zhiyong YANG
Chinese Journal of Medical Instrumentation 2023;47(4):370-376
The proton treatment control system is the supporting software of the proton therapy device, which specifically coordinates and controls the status and work of each subsystem. In this study, the software architecture and hardware implementation of the proton treatment control system was developed and built a foundation for the overall debugging. Using C# programming language and WPF programming techniques, TCP network communication protocol specified by the proton treatment technical document and MVVM pattern in Windows system, the logic design and implementation of each level were studied. Meanwhile, the communication interface between the subsystems under TCP communication protocol was agreed. The logic design and research of the setup field and treatment field were carried out. And the User Interface was designed and developed using the above technology. The program realizes the communication and interaction between the proton treatment control system and each subsystem, so as to control and monitor the whole treatment process. The proton treatment control system provides a software basis for the remote overall debugging and on-line monitor and control of proton treatment device.
Protons
;
User-Computer Interface
;
Software
;
Computers
;
Logic

Result Analysis
Print
Save
E-mail