1.Immunodynamic changes in a mouse model of malignant pleural effusion
Xiao-Lei WEI ; Xu GUO ; Chuang-Xin ZHANG ; Qi WANG ; Xiao-Fan LIU ; Ming-Ming SHAO ; Huan-Zhong SHI ; Kan ZHAI
Laboratory Animal Research 2026;42(1):59-67
Background:
Malignant pleural effusion (MPE), a common complication of advanced cancers, is associated with poor prognosis and reduced quality of life. Although host–tumor interactions are known to drive MPE development, the associated immune dynamics during disease progression remain unclear. Using a Lewis lung carcinoma-induced MPE model in C57BL/6JNidfc mice, we systematically evaluated general parameters and immune cell changes at two-day intervals throughout disease progression.
Results:
The day of Lewis lung carcinoma cell injection into the pleural space was designated as day 0. By day 10 post-injection (p.i.), MPE-bearing mice exhibited ~ 10% body weight loss, marking the experimental endpoint. Pleural tumor mass and pleural effusion volume were minimal up to day 4 p.i. but increased sharply from day 6 onward.CD45⁺ immune cell counts rose over time, and days 6, 8, and 10 p.i. marked key stages of MPE progression. On day 6, B cells, T cells, and natural killer cells, but not macrophages and neutrophils, increased significantly compared to earlier timepoints. By day 8, all immune cell subsets except T cells exceeded day 6 levels, and at day 10, natural killer cell numbers declined while others continued to increase. Besides, the numbers of CD8⁺ T cells, Th1 cells, regulatory T cells, and M2 macrophages progressively increased from day 6 to 10. Based on these data, days 6 and 10 were defined as early and advanced MPE stages, respectively, with distinct immune phenotypes. In advanced MPE, CD8⁺ T cells displayed reduced IFN-γ, TNF-α, Granzyme B, Perforin, FasL, and Ki-67, but upregulated PD-1 and CTLA-4 relative to early stage. Similarly, Th1 cells showed decreased IFN-γ, TNF-α, and IL-2 production along with reduced Ki-67 expression. Advanced-stage M2 macrophages exhibited lower MHC-II levels and impaired phagocytosis, but higher PD-L1 and IL-10 production, while neutrophils showed reduced TNF-α release and phagocytic activity.
Conclusions
Our findings characterize the temporal immune dynamics associated with MPE progression in a mouse model, revealing a transition from an early immunostimulatory state to a late immunosuppressive state. This study enhances our understanding of MPE immunopathogenesis and provides a foundation for developing precise, stagespecific therapeutic strategies.
2.Expert consensus on homogenization construction and management of pharmaceutical care in urban medical groups
Xiaoyan ZHANG ; Bing LIU ; Xin LI ; Erxia SHI ; Zhong LI ; Yanli LEI ; Shuai LIU ; Shuyao ZHANG ; Huishu TIAN
China Pharmacy 2026;37(12):1528-1534
OBJECTIVE To provide standardized guidance for the homogenization construction and management of pharmaceutical care in urban medical groups. METHODS This consensus was jointly initiated by the Therapeutic Drug Monitoring Professional Committee of the Chinese Pharmacological Society and the Expert Committee on Precision Clinical Medication of the Guangdong Pharmaceutical Association. Led by Guangzhou Red Cross Hospital, a drafting group of 7 members and an expert group of 36 members were organized. The outline of the Expert Consensus on Homogeneous Construction and Management of Pharmaceutical Care in Urban Medical Groups (hereinafter referred to as the “Consensus”) was discussed and finalized using the nominal group technique, and a preliminary draft was formed. The Delphi method was used for online c orrespondence review, and 12 external experts were invited for evaluation. After analyzing and revising expert opinions, the final Consensus was formed. RESULTS &CONCLUSIONS This Consensus defines the position setting and appointment procedures for the chief pharmacist, and establishes a three-tier professional guidance network of “chief pharmacist-regional/specialist pharmacist-pharmaceutical liaison of member institutions”. It formulates unified management standards for the drug supply catalog, establishes a full-process homogenization mechanism for prescription review, prescription commentation and comprehensive pharmaceutical care, and specifies the core functions and performance requirements of the prescription review system. It also supports by long-term mechanisms including cost allocation and performance assessment. This consensus can serve as a systematic reference for the homogeneous construction and management of pharmaceutical care systems in urban medical groups.
3.Analysis of the results from the 2024 national interlaboratory comparison for radionuclide measurement in bio-ash
Chunming ZHONG ; Xiang GAO ; Jin ZHANG ; Xin ZHANG ; Yuqi HUANG
Chinese Journal of Radiological Health 2026;35(3):331-335
Objective To enhance the gamma spectrometry analysis and detection capabilities of personnel in measuring radionuclides in bio-ash, and ensure the accuracy and precision of gamma spectrometer in our laboratory for the analysis of radionuclides in bio-ash. Methods The laboratory participated in the 2024 national interlaboratory comparison for radionuclide measurement in bio-ash. Radionuclides 241Am, 137Cs, and 40K in four different bio-ash samples were measured. Based on the measurement methods specified in GB/T 16145—2022, sample measurement, result calculation, and uncertainty evaluation were performed using spectrometry analysis software and sourceless efficiency calibration software. The measurement results and performance evaluation of the laboratory in the comparison were analyzed, and factors affecting gamma-spectrometry measurement and result interpretation were discussed. Results The relative deviation (D) of the measurement results for radionuclides 241Am and 137Cs in the four bio-ash samples ranged from −10.2% to 2.0% and −1.7% to 0.3%, respectively. The P statistic ranged from 7.0% to 12.5% and 5.0% to 10.8%, respectively. These results met the criteria of |D| ≤ 20% (MARB), |D| ≤ 2.58P, and P ≤ 20% (MARB). The ζ-scores for the measurement of 40K in the four bio-ash samples ranged from 0.8 to 1.3, satisfying the criterion of |ζ| < 2. All measurement results in this laboratory in the comparison were satisfactory. Conclusion The laboratory uses a high-purity germanium gamma spectrometer to measure radionuclides in bio-ash. The self-absorption correction method, analysis method, and uncertainty evaluation are appropriate, which can ensure the accuracy and precision of the measurement results. The measurement results are accurate and reliable.
5.Risk prediction of Reduning Injection batches by near-infrared spectroscopy combined with multiple machine learning algorithms.
Wen-Yu JIA ; Feng TONG ; Heng-Xu LIU ; Shu-Qin JIN ; Yong-Chao ZHANG ; Chen-Feng ZHANG ; Zhen-Zhong WANG ; Xin ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2025;50(2):430-438
In this paper, near-infrared spectroscopy(NIRS) was employed to analyze 129 batches of commercial products of Reduning Injection. The batch reporting rate was estimated according to the report of Reduning Injection in the direct adverse drug reaction(ADR) reporting system of the drug marketing authorization holder of the Center for Drug Reevaluation of the National Medical Products Administration(National Center for ADR Monitoring) from August 2021 to August 2022. According to the batch reporting rate, the samples of Reduning Injection were classified into those with potential risks and those being safe. No processing, random oversampling(ROS), random undersampling(RUS), and synthetic minority over-sampling technique(SMOTE) were then employed to balance the unbalanced data. After the samples were classified according to appropriate sampling methods, competitive adaptive reweighted sampling(CARS), successive projections algorithm(SPA), uninformative variables elimination(UVE), and genetic algorithm(GA) were respectively adopted to screen the features of spectral data. Then, support vector machine(SVM), logistic regression(LR), k-nearest neighbors(KNN), naive bayes(NB), random forest(RF), and artificial neural network(ANN) were adopted to establish the risk prediction models. The effects of the four feature extraction methods on the accuracy of the models were compared. The optimal method was selected, and bayesian optimization was performned to optimize the model parameters to improve the accuracy and robustness of model prediction. To explore the correlations between potential risks of clinical use and quality test data, TreeNet was employed to identify potential quality parameters affecting the clinical safety of Reduning Injection. The results showed that the models established with the SVM, LR, KNN, NB, RF, and ANN algorithms had the F1 scores of 0.85, 0.85, 0.86, 0.80, 0.88, and 0.85 and the accuracy of 88%, 88%, 88%, 85%, 91%, and 88%, respectively, and the prediction time was less than 5 s. The results indicated that the established models were accurate and efficient. Therefore, near infrared spectroscopy combined with machine learning algorithms can quickly predict the potential risks of clinical use of Reduning Injection in batches. Three key quality parameters that may affect clinical safety were identified by TreeNet, which provided a scientific basis for improving the safety standards of Reduning Injection.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/administration & dosage*
;
Machine Learning
;
Algorithms
;
Humans
;
Quality Control
6.Randomized, double-blind, parallel-controlled, multicenter, equivalence clinical trial of Jiuwei Xifeng Granules(Os Draconis replaced by Ostreae Concha) for treating tic disorder in children.
Qiu-Han CAI ; Cheng-Liang ZHONG ; Si-Yuan HU ; Xin-Min LI ; Zhi-Chun XU ; Hui CHEN ; Ying HUA ; Jun-Hong WANG ; Ji-Hong TANG ; Bing-Xiang MA ; Xiu-Xia WANG ; Ai-Zhen WANG ; Meng-Qing WANG ; Wei ZHANG ; Chun WANG ; Yi-Qun TENG ; Yi-Hui SHAN ; Sheng-Xuan GUO
China Journal of Chinese Materia Medica 2025;50(6):1699-1705
Jiuwei Xifeng Granules have become a Chinese patent medicine in the market. Because the formula contains Os Draconis, a top-level protected fossil of ancient organisms, the formula was to be improved by replacing Os Draconis with Ostreae Concha. To evaluate whether the improved formula has the same effectiveness and safety as the original formula, a randomized, double-blind, parallel-controlled, equivalence clinical trial was conducted. This study enrolled 288 tic disorder(TD) of children and assigned them into two groups in 1∶1. The treatment group and control group took the modified formula and original formula, respectively. The treatment lasted for 6 weeks, and follow-up visits were conducted at weeks 2, 4, and 6. The primary efficacy endpoint was the difference in Yale global tic severity scale(YGTSS)-total tic severity(TTS) score from baseline after 6 weeks of treatment. The results showed that after 6 weeks of treatment, the declines in YGTSS-TSS score showed no statistically significant difference between the two groups. The difference in YGTSS-TSS score(treatment group-control group) and the 95%CI of the full analysis set(FAS) were-0.17[-1.42, 1.08] and those of per-protocol set(PPS) were 0.29[-0.97, 1.56], which were within the equivalence boundary [-3, 3]. The equivalence test was therefore concluded. The two groups showed no significant differences in the secondary efficacy endpoints of effective rate for TD, total score and factor scores of YGTSS, clinical global impressions-severity(CGI-S) score, traditional Chinese medicine(TCM) response rate, or symptom disappearance rate, and thus a complete evidence chain with the primary outcome was formed. A total of 6 adverse reactions were reported, including 4(2.82%) cases in the treatment group and 2(1.41%) cases in the control group, which showed no statistically significant difference between the two groups. No serious suspected unexpected adverse reactions were reported, and no laboratory test results indicated serious clinically significant abnormalities. The results support the replacement of Os Draconis by Ostreae Concha in the original formula, and the efficacy and safety of the modified formula are consistent with those of the original formula.
Adolescent
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Male
;
Double-Blind Method
;
Drugs, Chinese Herbal/therapeutic use*
;
Tic Disorders/drug therapy*
;
Treatment Outcome
7.Application of motor behavior evaluation method of zebrafish model in traditional Chinese medicine research.
Xin LI ; Qin-Qin LIANG ; Bing-Yue ZHANG ; Zhong-Shang XIA ; Gang BAI ; Zheng-Cai DU ; Er-Wei HAO ; Jia-Gang DENG ; Xiao-Tao HOU
China Journal of Chinese Materia Medica 2025;50(10):2631-2639
The zebrafish model has attracted much attention due to its strong reproductive ability, short research cycle, and ease of maintenance. It has always been an important vertebrate model system, often used to carry out human disease research. Its motor behavior features have the advantages of being simpler, more intuitive, and quantifiable. In recent years, it has received widespread attention in the study of traditional Chinese medicine(TCM)for the treatment of sleep disorders, neurodegenerative diseases, fatigue, epilepsy, and other diseases. This paper reviews the characteristics of zebrafish motor behavior and its applications in the pharmacodynamic verification and mechanism research of TCM extracts, active ingredients, and TCM compounds, as well as in active ingredient screening and safety evaluation. The paper also analyzes its advantages and disadvantages, with the aim of improving the breadth and depth of zebrafish and its motor behavior applications in the field of TCM research.
Zebrafish/physiology*
;
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal/therapeutic use*
;
Disease Models, Animal
;
Drug Evaluation, Preclinical/methods*
;
Animals
;
Sleep Wake Disorders/physiopathology*
;
Epilepsy/physiopathology*
;
Neurodegenerative Diseases/physiopathology*
;
Fatigue/physiopathology*
;
Behavior, Animal/physiology*
;
Motor Activity/physiology*
8.Development and Initial Validation of the Multi-Dimensional Attention Rating Scale in Highly Educated Adults.
Xin-Yang ZHANG ; Karen SPRUYT ; Jia-Yue SI ; Lin-Lin ZHANG ; Ting-Ting WU ; Yan-Nan LIU ; Di-Ga GAN ; Yu-Xin HU ; Si-Yu LIU ; Teng GAO ; Yi ZHONG ; Yao GE ; Zhe LI ; Zi-Yan LIN ; Yan-Ping BAO ; Xue-Qin WANG ; Yu-Feng WANG ; Lin LU
Chinese Medical Sciences Journal 2025;40(2):100-110
OBJECTIVES:
To report the development, validation, and findings of the Multi-dimensional Attention Rating Scale (MARS), a self-report tool crafted to evaluate six-dimension attention levels.
METHODS:
The MARS was developed based on Classical Test Theory (CTT). Totally 202 highly educated healthy adult participants were recruited for reliability and validity tests. Reliability was measured using Cronbach's alpha and test-retest reliability. Structural validity was explored using principal component analysis. Criterion validity was analyzed by correlating MARS scores with the Toronto Hospital Alertness Test (THAT), the Attentional Control Scale (ACS), and the Attention Network Test (ANT).
RESULTS:
The MARS comprises 12 items spanning six distinct dimensions of attention: focused attention, sustained attention, shifting attention, selective attention, divided attention, and response inhibition.As assessed by six experts, the content validation index (CVI) was 0.95, the Cronbach's alpha for the MARS was 0.78, and the test-retest reliability was 0.81. Four factors were identified (cumulative variance contribution rate 68.79%). The total score of MARS was correlated positively with THAT (r = 0.60, P < 0.01) and ACS (r = 0.78, P < 0.01) and negatively with ANT's reaction time for alerting (r = -0.31, P = 0.049).
CONCLUSIONS
The MARS can reliably and validly assess six-dimension attention levels in real-world settings and is expected to be a new tool for assessing multi-dimensional attention impairments in different mental disorders.
Humans
;
Adult
;
Male
;
Attention/physiology*
;
Female
;
Middle Aged
;
Reproducibility of Results
;
Young Adult
;
Psychometrics
9.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
10.Protocol for development of Guideline for Interventions on Cervical Spine Health.
Jing LI ; Guang-Qi LU ; Ming-Hui ZHUANG ; Xin-Yue SUN ; Ya-Kun LIU ; Ming-Ming MA ; Li-Guo ZHU ; Zhong-Shi LI ; Wei CHEN ; Ji-Ge DONG ; Le-Wei ZHANG ; Jie YU
China Journal of Orthopaedics and Traumatology 2025;38(10):1083-1088
Cervical spine health issues not only seriously affect patients' quality of life but also impose a heavy burden on the social healthcare system. Existing guidelines lack sufficient clinical guidance on lifestyle and work habits, such as exercise, posture, daily routine, and diet, making it difficult to meet practical needs. To address this, relying on the China Association of Chinese Medicine, Wangjing Hospital of China Academy of Chinese Medical Sciences took the lead and joined hands with more than ten institutions to form a multidisciplinary guideline development group. For the first time, the group developed the Guidelines for Cervical Spine Health Intervention based on evidence-based medicine methods, strictly following the standardized procedures outlined in the World Health Organization Handbook for Guideline Development and the Guiding Principles for the Formulation/Revision of Clinical Practice Guidelines in China (2022 Edition). This proposal systematically explains the methods and steps for developing the guideline, aiming to make the guideline development process scientific, standardized, and transparent.
Humans
;
Practice Guidelines as Topic/standards*
;
Cervical Vertebrae
;
China

Result Analysis
Print
Save
E-mail