1.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
2.BRD4 regulates m6A of ESPL1 mRNA via interaction with ALKBH5 to modulate breast cancer progression.
Haisheng ZHANG ; Linlin LU ; Cheng YI ; Tao JIANG ; Yunqing LU ; Xianyuan YANG ; Ke ZHONG ; Jiawang ZHOU ; Jiexin LI ; Guoyou XIE ; Zhuojia CHEN ; Zongpei JIANG ; Gholamreza ASADIKARAM ; Yanxi PENG ; Dan ZHOU ; Hongsheng WANG
Acta Pharmaceutica Sinica B 2025;15(3):1552-1570
The interaction between m6A-methylated RNA and chromatin modification remains largely unknown. We found that targeted inhibition of bromodomain-containing protein 4 (BRD4) by siRNA or its inhibitor (JQ1) significantly decreases mRNA m6A levels and suppresses the malignancy of breast cancer (BC) cells via increased expression of demethylase AlkB homolog 5 (ALKBH5). Mechanistically, inhibition of BRD4 increases the mRNA stability of ALKBH5 via enhanced binding between its 3' untranslated regions (3'UTRs) with RNA-binding protein RALY. Further, BRD4 serves as a scaffold for ubiquitin enzymes tripartite motif containing-21 (TRIM21) and ALKBH5, resulting in the ubiquitination and degradation of ALKBH5 protein. JQ1-increased ALKBH5 then demethylates mRNA of extra spindle pole bodies like 1 (ESPL1) and reduces binding between ESPL1 mRNA and m6A reader insulin like growth factor 2 mRNA binding protein 3 (IGF2BP3), leading to decay of ESPL1 mRNA. Animal and clinical studies confirm a critical role of BRD4/ALKBH5/ESPL1 pathway in BC progression. Further, our study sheds light on the crosstalks between histone modification and RNA methylation.
3. Research progress of antineoplastic drugs targeting platelets
Yue-Ke ZHOU ; Cheng QIAN ; Yu TANG ; Zhong-Hong WEI ; Yin LU ; Ai-Yun WANG ; Yin LU ; Ai-Yun WANG
Chinese Pharmacological Bulletin 2024;40(1):20-25
Platelets have long been recognized as key players in hemostasis and thrombosis; however, there is growing evidence that they are also involved in cancer. Preclinical and clinical studies have shown that platelets can promote tumorigenesis and metastasis through various crosstalks between platelets and cancer cells. Platelets play an active role in all stages of tumorigenesis, including tumor growth, tumor cell extravasation, and metastasis. In addition, thrombocytosis in cancer patients is associated with poor patient survival. Platelets are also well-placed to coordinate local and distant tumor-host interactions due to the a- bundance of microparticles and exosomes. Therefore, antitumor drugs targeting platelets have great development and application prospects. The following will review the research progress of anti-tumor drugs targeting platelets.
4.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
5.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
6.Catheter-related bloodstream infection caused by Staphylococcus pas-teuri:one case report
Chong-Zhen WANG ; Shan ZHONG ; Li-Xia XU ; Li-Cheng WANG ; Xiao-Ying FU ; Huan LI ; Yuan-Li LI ; Xiong ZHU ; Hai CHEN ; Dong-Ke CHEN
Chinese Journal of Infection Control 2024;23(8):1040-1043
One patient was admitted to a hospital due to"sepsis,chronic kidney disease,type 2 diabetes,shock,and cerebral infarction".Patient's blood specimen was taken for clinical examination.Aerobic and anaerobic culture results of catheter blood and venous blood were both positive.The pathogen was identified as Staphylococcus pas-teuri by VITEK MS,and the patient was diagnosed as catheter-related bloodstream infection caused by Staphylo-coccus pasteuri.Clinical empirical use of piperacillin for anti-infection treatment was ineffective,and vancomycin was eventually used for treatment based on in vitro antimicrobial susceptibility testing.Patient's condition improved after removing the venous catheter.There are currently no reported cases of Staphylococcus pasteuri in China.Ear-ly identification of pathogen and adjustment of treatment plans based on antimicrobial susceptibility testing results are crucial for effective treatment of this case.
7.A case of emergency transcatheter aortic valve replacement treatment for aortic stenosis complicated with acute heart failure shock in primary hospital
Huan GUO ; Yu-Dong LI ; Nian-Guo DONG ; Xiao-Ke SHANG ; Yu-Cheng ZHONG ; Chang-Dong ZHANG ; Ling-Bo ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):291-294
Aortic valve stenosis,as a common heart valve disease,progresses rapidly and has a poor clinical prognosis.In the case of combined acute heart failure,the pumping function of the heart is severely impaired,which may lead to a significant decrease in cardiac output,resulting in a state of shock.Transcatheter aortic valve replacement(TAVR)has become a first-line treatment for elderly patients with aortic valve stenosis since its first successful case in 2002.In China,with the advancement of technology and the strengthening of physician training,the capacity of grassroots hospitals in TAVR treatment is increasing.This case reports a patient with severe aortic valve stenosis accompanied by acute heart failure and shock status who received emergency TAVR treatment at a grassroots hospital.Due to limitations in conditions,TAVR was urgently implemented without extracorporeal circulation and extracorporeal membrane oxygenation support.The patient's blood pressure immediately rose to 105/65 mmHg after valve dilation during surgery,and the postoperative symptoms were significantly relieved.Follow up color Doppler ultrasound showed that the stenosis was relieved and the heart function was significantly improved.The success of this surgery provides a reference for emergency TAVR treatment in patients with severe aortic valve stenosis and heart failure in grassroots hospitals.
8.D-shant atrial shunt device implantable in patients with severe pulmonary hypertension and right heart failure:one case report and literature review
Shu-Na XIAO ; Wen-Jie GAO ; Xiao-Ke SHANG ; Chang-Dong ZHANG ; Yu-Cheng ZHONG ; Ying ZHI ; Lin-Li QIU ; Yan-Fei DONG ; Yan HE ; Wei TIAN ; Wen-Wen TANG
Chinese Journal of Interventional Cardiology 2024;32(8):472-477
To evaluate the effectiveness and safety of implantable D-shant atrial shunt device in patients with severe pulmonary arterial hypertension(PAH)and right heart failure.A 53-year-old female patient diagnosed with severe idiopathic PAH and right heart failure,her WHO FC grade was Ⅳ.The right heart catheter and implantation of D-shant atrial shunt device were performed under local anesthesia on November 30,2021.A 6 mm×4 cm peripheral artery balloon was selected to dilate the atrial septum and a D-shant atrial shunt device with a fixed 4 mm diameter orifice was implanted into the heart.The clinical symptoms and hemodynamics of the patient was improved after the intervention.Implantation of atrial shunt device as a palliative therapy to established a right to left shunt is another strategy for treating patients with severe PAH in late period,which has good effectiveness and safety.It could be the last replacement therapy to improve symptoms and prolonged lives to drug resistant and severe PAH patients.
9.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.
10.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.