1.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
2.Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality.
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU
Chinese Journal of Medical Instrumentation 2025;49(2):176-180
OBJECTIVE:
To investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT.
RESULTS:
For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant.
CONCLUSION
Different scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
Cone-Beam Computed Tomography/instrumentation*
;
Phantoms, Imaging
;
Particle Accelerators
3.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
4.Clinical study of the effect of different CBCT scanning parameters on image quality and positioning error of cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Jiang LIU
China Medical Equipment 2024;21(11):18-24
Objective:To assess the effects of the scanning parameters of cone beam computed tomography(CBCT)on image quality,positioning error and additional radiation dose for patients with cervical cancer after tube voltage was reduced,so as to explore scanning conditions that was suitable to patients with cervical cancer.Methods:Seventy-two patients with cervical cancer who received radiotherapy in Deyang People's Hospital from January 2020 to August 2022 were selected.According to different scanning parameters,they were divided into low-dose group A(120 kV,154.4 mAs),low-dose group B(120 kV,228.8 mAs)and conventional group[adopted business-supplied scan sequences(120 kV,675.8 mAs)].The CBCT scan image was obtained by decreasing the tube voltage and tube current,and reducing scanning angle.The registration results of positioning error of low-dose group A,B and conventional group on three directions included left and right(x-axis),head and foot(y-axis)and abdominal and back(z-axis)were respectively obtained,and the results were analyzed by variance analysis.The Catphan503 phantom of X-ray volumetric imaging(XVI)was used to measure the image quality of the corresponding 3 groups,and the further comparison was conducted.Results:There were no significant differences between the three groups in the scanning parameters on x,y and z axis directions for positioning error of patients with cervical cancer(P>0.05).The scanning times of low-dose group A and B were approximately 1 minute,and the scanning time of conventional group was approximately 2 minutes.The noises of low-dose group A and B,and conventional group were respectively 36.51%,26.09%and 18.37%,and the radiation dose that was generated by CBCT image scanning in group A was correspondingly reduced.Conclusion:The reductions of scanning speed and collimator size of CBCT scanning parameters do not affect the positioning error and image quality,and it can decrease the scanning time and additional radiation dose of patients in undergoing radiotherapy.
5.Effect of levothyroxine on abortion rate and preterm birth rate in pregnant women with thyroid autoimmunity and normal thyroid function: a systematic review and meta-analysis
Keng FENG ; Yihua YANG ; Yudi LUO ; Lingling ZHU ; Bo LIU ; Zhiyao WEI ; Rong DENG ; Qiuyue WEN ; Yin BEN ; Aiping QIN
Chinese Journal of Reproduction and Contraception 2022;42(7):717-723
Objective:To evaluate the efficacy of oral levothyroxine on abortion rate and preterm birth rate in pregnant women with thyroid autoimmunity (TAI) and normal thyroid function.Methods:The relevant studies of oral levothyroxine tablets in the treatment of TAI pregnant women were systematically searched in Pubmed, Cochrane, CBM, CNKI, VIP and Wanfang databases. The retrieval period was established until August 2020. Two researchers independently screened the literatures, extracted the data and evaluated the risk of bias in the included study. Meta-analysis was performed using Revman5.3 software.Results:1) Totally six eligible studies were all randomized controlled studies, involving 1427 patients. 2) Compared with control group, the meta-analysis suggests oral levothyroxine tablets cannot effectively reduce the preterm delivery rate and the abortion rate. 3) Further subgroup analysis of the data according to the natural pregnancy group and assisted reproduction group found that oral levothyroxine tablets in natural pregnancy women with TAI can effectively reduce the preterm delivery rate ( RR=0.54, 95% CI=0.31-0.95, P=0.03), but not reduce the abortion rate ( RR=0.86, 95% CI=0.69-1.06, P=0.15). However, oral levothyroxine tablets cannot reduce the abortion rate for TAI women conceived by reproductive technology ( RR=0.80, 95% CI=0.47-1.36, P=0.41). Conclusion:Oral levothyroxine tablets can effectively reduce the premature delivery rate of TAI women who are naturally pregnant, but it is not beneficial to reduce the abortion rate. There is only one study on TAI women who are pregnant with reproductive technology, so it is impossible to evaluate whether this population can benefit from taking levothyroxine tablets. In view of the above results, it is recommended that the two groups of patients be managed separately.
6.Effect of levothyroxine on abortion rate and preterm birth rate in pregnant women with thyroid autoimmunity and normal thyroid function: a systematic review and meta-analysis
Keng FENG ; Yihua YANG ; Yudi LUO ; Lingling ZHU ; Bo LIU ; Zhiyao WEI ; Rong DENG ; Qiuyue WEN ; Yin BEN ; Aiping QIN
Chinese Journal of Reproduction and Contraception 2022;42(7):717-723
Objective:To evaluate the efficacy of oral levothyroxine on abortion rate and preterm birth rate in pregnant women with thyroid autoimmunity (TAI) and normal thyroid function.Methods:The relevant studies of oral levothyroxine tablets in the treatment of TAI pregnant women were systematically searched in Pubmed, Cochrane, CBM, CNKI, VIP and Wanfang databases. The retrieval period was established until August 2020. Two researchers independently screened the literatures, extracted the data and evaluated the risk of bias in the included study. Meta-analysis was performed using Revman5.3 software.Results:1) Totally six eligible studies were all randomized controlled studies, involving 1427 patients. 2) Compared with control group, the meta-analysis suggests oral levothyroxine tablets cannot effectively reduce the preterm delivery rate and the abortion rate. 3) Further subgroup analysis of the data according to the natural pregnancy group and assisted reproduction group found that oral levothyroxine tablets in natural pregnancy women with TAI can effectively reduce the preterm delivery rate ( RR=0.54, 95% CI=0.31-0.95, P=0.03), but not reduce the abortion rate ( RR=0.86, 95% CI=0.69-1.06, P=0.15). However, oral levothyroxine tablets cannot reduce the abortion rate for TAI women conceived by reproductive technology ( RR=0.80, 95% CI=0.47-1.36, P=0.41). Conclusion:Oral levothyroxine tablets can effectively reduce the premature delivery rate of TAI women who are naturally pregnant, but it is not beneficial to reduce the abortion rate. There is only one study on TAI women who are pregnant with reproductive technology, so it is impossible to evaluate whether this population can benefit from taking levothyroxine tablets. In view of the above results, it is recommended that the two groups of patients be managed separately.
7.Clinical study of 41 children with acute necrotizing encephalopathy
Hongmin ZHU ; Cong YAO ; Mengqing LUO ; Zhiyao TIAN ; Tao LEI ; Gefei WU ; Jiasheng HU ; Zhisheng LIU
Chinese Journal of Applied Clinical Pediatrics 2021;36(16):1257-1261
Objective:To investigate the clinical features and prognosis of acute necrotizing encephalopathy (ANE) in children.Methods:The clinical data and follow-up information of 41 pediatric patients with ANE treated in Wuhan Children′s Hospital, Tongji Medical College, Huazhong University of Science & Technology from January 2014 to September 2019 were retrospectively reviewed.Results:The 41 patients included 23 males and 18 females with the onset age of (4.4±3.2) years.The main prodromal symptoms were gastrointestinal (20/41 cases, 48.8%) and respiratory infections (19/41 cases, 46.3%). Acute encephalopathy progressed rapidly following the prodromal infection [29 cases (70.7%) ≤2 days], and patients had clinical manifestations of coma (32/41 cases, 78.0%), convulsion (32/41 cases, 78.0%), multiple organ dysfunction (27/41 cases, 65.9%), shock and disseminated intravascular coagulation were rarely occured, and 28 cases (68.3%) were admitted to intensive care unit for treatment.Brain magnetic resonance imaging (MRI) showed lesion involving thalamus (41/41 cases, 100.0%), periventricular white matter (34/41 cases, 82.9%), brainstem (31/41 cases, 75.6%), basal ganglia (26/41 cases, 63.4%), cerebral cortex and subcortex (20/41 cases, 48.8%) and cerebellum (18/41 cases, 43.9%). The common presentations on the apparent diffusion coefficient mapping of brain MRI were " tricolor pattern" or " bicolor pattern" of the thalamus.During follow-up (≥ 6 months), MRI showed that hemorrhage, cystic degeneration and atrophy changed dynamically with the progression of ANE.All cases were treated with glucocorticoids, 38 cases(92.7%) with intravenous immune globulin.Seven cases (17.1%) were died and the 34 survivors had different degrees of neurological dysfunction.Conclusions:ANE in children is a distinctive type of clinicoradiologic syndrome with rapid progression and various presentations.Brain MRI has typical imaging characteristics and dynamically indicates the progression of this disease.The treatment options are still limited, the prognosis is poor and the survivors are often with neurological dysfunction.
8.Effects of exogenous biliverdin on expression of Litaf in PC12 cells subjected to oxygen-glucose deprivation and restoration
Junjie LI ; Zhiyao ZOU ; Lijia PENG ; Jing LUO ; Li XIONG ; Jia LIU ; Tinghua WANG ; Jianlin SHAO
Chinese Journal of Anesthesiology 2020;40(3):347-349
Objective:To evaluate the effects of exogenous biliverdin (BV) on the expression of Litaf in PC12 cells subjected to oxygen-glucose deprivation and restoration (OGD/R).Methods:PC12 cells were seeded in a 96-well cell culture plate at a density of 1×10 4 cells/well for 3 days and were divided into 3 groups ( n=18 each) by a random number table method: control group (group C), OGD/R group, and biliverdin group (BV group). Group C was incubated in a 37 ℃ incubator (95% air+ 5%CO 2) for 6 h. To establish the OGD/R model, cells were incubated with sugar-free medium in a 37 ℃ incubator (95% air+ 5%CO 2) for 2 h, and the medium was then replaced with normal medium and cells were continuously incubated in a 37 ℃ incubator (95% N 2+ 5% CO 2). In BV group, 2 μg/ml biliverdin was added immediately after oxygen-glucose restoration.Cells in 6 wells in each group were selected at 6 h of restoration for determination of the expression of Litaf protein and mRNA (by real-time polymerase chain reaction) and tumor necrosis factor-alpha (TNF-α) concentration (by enzyme-linked immunosorbent assay). Results:Compared with group C, the expression of Litaf protein and mRNA was significantly up-regulated, and TNF-α concentration in supernatant was increased in group OGD/R ( P<0.05). Compared with group OGD/R, the expression of Litaf protein and mRNA was significantly down-regulated, and TNF-α concentration in supernatant was decreased in group BV ( P<0.05). Conclusion:The mechanism by which exogenous biliverdin reduces OGD/R damage to PC12 cells is related to inhibiting up-regulated expression of Litaf and alleviating the inflammatory responses.
9.Study on Active Components and Mechanism of Volatile Oil of Citri reticulatae Preventing and Treating Alzhei- mer’s Disease Based on GC-MS and Network Pharmacology
Tenghua WANG ; Yingyi LUO ; Yuchen WANG ; Zhiyao REN ; Jianxin TANG ; Yongmei LI ; Yi FANG ; Bo WU
China Pharmacy 2020;31(17):2093-2100
OBJECTIVE:To predict the active components and potential target of volatile oil of Citri reticulatae preventing and treating Alzheimer ’s disease (AD). METHODS :The volatile oil of C. reticulatae was determined by GC-MS ,and identified according to NIST 11.L database and manual data analysis. The active components and targets of volatile oil of C. reticulatae were predicted through TCMSP and PharmMapper database. The related targets of AD were obtained by using GeneCards and OMIM databases. Venny 2.1.0 software mapping was used to obtain the direct targets of volatile oil of C. reticulatae against AD. Core nodes were mined with STRING database and Cytoscape 7.2.1 software,and the indirect targets of volatile oil of C. reticulatae against AD were obtained by mapping and duplication coith Venny 2.1.0 software. With the help of DAVID 6.7 database,the above direct and indirect targets (i.e. action targets )were used for gene ontology (GO)function enrichment analysis and KEGG pathway enrichment analysis. Using Cytoscape 7.2.1 software, topology analysis was conducted for the network of “active components-acting targets ”of volatile oil of C. reticulatae ,with node degree value ,betweenness centrality and closeness centrality as indexes ,then key components and key targets were mined. RESULTS & CONCLUSIONS :A total of 40 chemical components in volatile oil were identified by GC-MS ,all of them were active components ,including D-limonene,γ-terpinene,etc. A total of 151 active components-corresponding targets and 1 291 AD-related targets were mined ,including 48 direct targets and 41 indirect targets. The above 89 targets were mainly concentrated in cell fraction ,axon,cytosol and other cell components ;intracellular signaling cascade ,response to organic substance and other biological processes ;protein kinase activity and amine receptor activity and other molecular functions ;as well as cancer pathway ,calcium signaling pathway and neurotrophin signaling pathway (P< 0.05). A total of 10 key components including α-terpinene,β-elemen,thymol and (-)-4-terpineol,as well as 21 key targets such as androgen receptor ,prostaglandin G/H synthase 2,mitogen activated protein kinase 14,muscarinic acetylcholine receptor M 1 were excavated ,indicating the effect of volatile oil of C. reticulatae against AD had the characteristics of multi-component , multi-target and multi-channel.
10.Application of Double Contrast-enhanced Ultrasonography in the Diagnosis of Gastric Cancer
Xiaomao LUO ; Yuan ZHANG ; Hui SHAO ; Zhiyao LI ; Shuchuan TAN ; Zhirui CHUAN ; Lichun YANG
Journal of Kunming Medical University 2016;37(7):30-34
Objective To investigate the clinical value of double contrast-enhanced ultrasonography (DCUS) for the diagnosis of gastric cancer.Methods A retrospective analysis was performed to review the DCUS data of 26 patients which were diagnosed as gastric cancer by pathology in the third affiliated hospital of Kunming Medical University from October 2014 to July 2015.The analysis results were compared with postoperative pathology to get accuracy rates.Results The located accuracy,qualitative accuracy and accuracy at T phase of DUCS was 100% (26/26),100% (26/26) and 88.5% (23/26),respectively.Compared with color doppler flow imaging (CDFI),the qualitative accuracy of DUCS was much higher (P < 0.05).The accuracy of DUCS at T phase was higher than that of CDFI with no statistical significance (P > 0.05) Conclusion DUCS has an important application value in the diagnosis of gastric cancer.

Result Analysis
Print
Save
E-mail