1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.The application of Hood technique in robotic-assisted radical prostatectomy
Jun YANG ; Jia HU ; Wei GUAN ; Zheng LIU ; Zhihua WANG ; Zhiquan HU ; Qianyuan ZHUANG ; Shaogang WANG
Chinese Journal of Urology 2022;43(3):176-180
Objective:To explore the feasibility, safety and short-term effect of the Hood technique in robotic-assisted radical prostatectomy (RARP).Methods:The data of 24 patients with localized prostate cancer underwent RARP with Hood technique From June 2020 to March 2021 were retrospectively reviewed. The mean age was 67.8 (57-76) years, and the mean body mass index was 25.17(18.31-32.54)kg/m 2. The mean tPSA value was 18.36(4.21-67.57)ng/ml and the mean biopsy Gleason score was 7.3 (6-8). In term of the clinical T stage, the 24 cases were composed of the T 1c stage in 1 case, T 2a stage in 5 cases, T 2b stage in 4 cases and T 2c stage in 14 cases. During Hood technique, the anterior bladder were limitedly isolated without exposing the outline of pelvis and prostate. Results:All the cases were completed robotically without conversion, transfusion or positive surgical margin. The average robot-assisted operation time was 84.5(63-110) mins. Estimated blood loss was 75.3(20-180) ml. The average time for maintaining the drain was 3.7(3-5) days. The mean postoperative hospital stay was 7.1(4-11) days. The mean catheterization time was 7.3(6-9) days after surgery. 23 patients achieved continence immediately after catheter removal, while 1 patient had continence full-recovery 2 weeks after surgery. The mean surgical Gleason score was 7.9 (6-9). In term of the surgical T stage, the 24 cases were composed of the pT 2a stage in 4 case, T 2b stage in 6 cases, T 2c stage in 14 cases.During 3-12 months’ follow-up, no biochemical recurrence was found. Conclusions:Hood technique were safe and valid in RARP with excellent immediate continence recovery. It facilitated Retzius sparing in a convenient approach with low positive surgical margin rate.
6.Expression and clinical significance of p57KIP2,cyclin D1,and cyclin E in male breast can-cer
Zuqiang LUO ; Zhiquan ZHUANG ; Weisong DONG ; Xiaomeng TU
Chinese Journal of Clinical Oncology 2018;45(3):126-130
Objective:To explore the relationship between the expression of p57KIP2,cyclin D1,and cyclin E receptors in male breast can-cer(MBC)and its clinical significance.Methods:Data of MBC cases diagnosed in The First Affiliated Hospital of Wenzhou Medical Uni-versity between January 2000 and December 2016 were reviewed.Forty cases of infiltrating ductal carcinoma(IDC)and 20 cases of male ductal carcinoma in situ(DCIS)were selected,and 20 cases of gynecomastia(GYM)were selected as controls.The expression of p57KIP2,cyclin D1,and cyclin E mRNA and protein in the tissue samples obtained from IDC,DCIS,and GYM cases were measured by re-verse transcription polymerase chain reaction and immunohistochemistry,respectively.Results:The expression of p57KIP2mRNA in IDC was 0.18±0.07,which was lower than that in DCIS(0.42±0.05)and GYM(0.75±0.04).The rate of p57KIP2positivity in IDC was 25%(10/40),which was lower than that in DCIS 60%(12/20)and GYM 90%(18/20).There were significant differences in the expression of p57KIP2mRNA and protein among the three groups(P<0.05).The expression of cyclin D1 and cyclin E mRNA in IDC was 0.92±0.12 and 0.96±0.08,which was higher than that in DCIS(0.72±0.06,0.64±0.01)and GYM(0.38±0.03,0.21±0.02),respectively.Cyclin D1 and cy-clin E protein positive rates in IDC were 90%(36/40)and 88%(35/40),which were higher than those in DCIS[80%(16/20),85%(17/20)],and GYM[25%(5/20),20%(4/20)].In IDC tissues,the expression of p57KIP2,cyclin D1,and cyclin E proteins was associated with the clinical stage and histological grade(P<0.05),and the expression of p57KIP2protein was correlated with axillary node metastasis(P<0.05).There was a negative correlation between the expression of p57KIP2and cyclin D1 and between p57KIP2and cyclin E.However,the correlation between cyclin D1 and cyclin E expression was positive(P<0.05).Conclusions:p57KIP2,cyclin D1,and cyclin E may play an im-portant role in the development and progression of MBC.Combined clinicopathological detection of p57KIP2,cyclin D1,and cyclin E can aid future research on MBC.
7.Effect of capsaicin on intestinal permeation of P-glycoprotein substrate rhodamine 123 and fluorescein sodium in rats.
Qianying LIANG ; Lian DUAN ; Zhiquan ZHUANG ; Boxin ZHAO ; Yuan LIU ; Shengqi WANG ; Fuheng YANG ; Sijia LIU ; Guofeng LI
Journal of Southern Medical University 2015;35(5):724-732
OBJECTIVETo investigate the role of capsaicin in regulating permeation of P-gp substrate rhodamine 123 (R123) across the jejunum, ileum and colon membranes of rats.
METHODSThe permeability of R123 or fluorescein sodium (CF) across the jejunum, ileum and colon membranes of male SD rats was evaluated using a Ussing chamber. The concentration of R123 or CF in the receptor was determined using fluorospectrophotometry to calculate the apparent permeability coefficient (Papp).
RESULTSCompared with the blank control group, capsaicin increased the permeability of R123 across jejunal membranes in the mucosal-to-serosal (M-S) direction and decreased its permeability in the serosal-to-mucosal (S-M) direction, but produced no obvious effect on R123 transport across the ileum or colon membranes. Capsaicin caused a regional increase in the permeability of CF across the jejunal membranes compared with the control group, but CF transport across the ileum and colon membranes was not affected.
CONCLUSIONCapsaicin can affect the transport of R123 and CF across rat jejunal membranes, and this effect is shows an obvious intestine segment-related difference probably because of the different distribution of P-gp or tight junction in the intestines. This finding suggests that capsaicin is a weak P-gp inhibitor and an improver of mucous membrane channels.
ATP-Binding Cassette, Sub-Family B, Member 1 ; metabolism ; Animals ; Capsaicin ; pharmacology ; Colon ; metabolism ; Fluorescein ; pharmacokinetics ; Ileum ; metabolism ; Intestinal Absorption ; Jejunum ; metabolism ; Male ; Permeability ; Rats ; Rats, Sprague-Dawley ; Rhodamine 123 ; pharmacokinetics
8.Effect of capsaicin on intestinal permeation of P-glycoprotein substrate rhodamine 123 and fluorescein sodium in rats
Qianying LIANG ; Lian DUAN ; Zhiquan ZHUANG ; Boxin ZHAO ; Yuan LIU ; Shengqi WANG ; Fuheng YANG ; Sijia LIU ; Guofeng LI
Journal of Southern Medical University 2015;(5):724-727,732
Objective To investigate the role of capsaicin in regulating permeation of P-gp substrate rhodamine 123 (R123) across the jejunum, ileum and colon membranes of rats. Methods The permeability of R123 or fluorescein sodium (CF) across the jejunum, ileum and colon membranes of male SD rats was evaluated using a Ussing chamber. The concentration of R123 or CF in the receptor was determined using fluorospectrophotometry to calculate the apparent permeability coefficient (Papp). Results Compared with the blank control group, capsaicin increased the permeability of R123 across jejunal membranes in the mucosal-to-serosal (M-S) direction and decreased its permeability in the serosal-to-mucosal (S-M) direction, but produced no obvious effect on R123 transport across the ileum or colon membranes. Capsaicin caused a regional increase in the permeability of CF across the jejunal membranes compared with the control group, but CF transport across the ileum and colon membranes was not affected. Conclusion Capsaicin can affect the transport of R123 and CF across rat jejunal membranes, and this effect is shows an obvious intestine segment-related difference probably because of the different distribution of P-gp or tight junction in the intestines. This finding suggests that capsaicin is a weak P-gp inhibitor and an improver of mucous membrane channels.
9.Effect of capsaicin on intestinal permeation of P-glycoprotein substrate rhodamine 123 and fluorescein sodium in rats
Qianying LIANG ; Lian DUAN ; Zhiquan ZHUANG ; Boxin ZHAO ; Yuan LIU ; Shengqi WANG ; Fuheng YANG ; Sijia LIU ; Guofeng LI
Journal of Southern Medical University 2015;(5):724-727,732
Objective To investigate the role of capsaicin in regulating permeation of P-gp substrate rhodamine 123 (R123) across the jejunum, ileum and colon membranes of rats. Methods The permeability of R123 or fluorescein sodium (CF) across the jejunum, ileum and colon membranes of male SD rats was evaluated using a Ussing chamber. The concentration of R123 or CF in the receptor was determined using fluorospectrophotometry to calculate the apparent permeability coefficient (Papp). Results Compared with the blank control group, capsaicin increased the permeability of R123 across jejunal membranes in the mucosal-to-serosal (M-S) direction and decreased its permeability in the serosal-to-mucosal (S-M) direction, but produced no obvious effect on R123 transport across the ileum or colon membranes. Capsaicin caused a regional increase in the permeability of CF across the jejunal membranes compared with the control group, but CF transport across the ileum and colon membranes was not affected. Conclusion Capsaicin can affect the transport of R123 and CF across rat jejunal membranes, and this effect is shows an obvious intestine segment-related difference probably because of the different distribution of P-gp or tight junction in the intestines. This finding suggests that capsaicin is a weak P-gp inhibitor and an improver of mucous membrane channels.
10.Simultaneous determination of eight iridoid glycosides in Gardeniae fructus by HPLC.
Wuzhan LIU ; Jianwei FAN ; Yanhong GAO ; Xinjian QIU ; Huifang ZHUANG ; Zhiquan ZHAO
China Journal of Chinese Materia Medica 2012;37(16):2417-2421
OBJECTIVETo establish an HPLC method for simultaneous determination of eight iridiods in Gardeniae Fructus.
METHODKromasil C18 column (4. 6 mm x 250 mm, 5 microm) was adopted, with acetonitrile-water-trifluoroacetic acid (6:94: 0.05) as the mobile phase at the flow rate of 1.0 mL x min(-1). The detection wavelength was set at 238 nm, and the column temperature was 40 degrees C.
RESULTThe linear ranges of geniposide, gardoside, shanzhiside, geniposidic acid, deacetyl asperulosidic acid methyl ester, gardenoside, scandoside methyl ester, and genipin gentiobioside were 1.5036 - 15.036, 0.04256 - 0.4256, 0.1038 - 1.038, 0.00992 - 0.0992, 0.02332 - 0.2332, 0.4128 - 4.128, 0.02040 - 0.2040 and 0.4656 - 4.656 microg, respectively. Their average recoveries were 99.6% , 100.6% , 101.2%, 99.5%, 100.3% , 98.7%, 99.8% and 100.1%, respectively.
CONCLUSIONThe method shows good separation and it is so simple, accurate and highly repeatable that it can be used for providing basis for quality control of Gardeniae Fructus.
Chromatography, High Pressure Liquid ; methods ; Drugs, Chinese Herbal ; analysis ; isolation & purification ; Gardenia ; chemistry ; Iridoid Glycosides ; analysis ; isolation & purification

Result Analysis
Print
Save
E-mail