1.Construction of a competency evaluation index system for clinical teachers in teaching hospitals
Yuan ZHANG ; Zhihui ZOU ; Manjie ZHANG ; Zhiquan LIN ; Chuhong YU
Chinese Journal of Medical Education Research 2025;24(2):192-198
Objective:To construct a scientific and reliable clinical teacher competency evaluation index system, and provide a reference for strengthening the construction of clinical teachers in teaching hospitals.Methods:Based on literature research and group discussion, the initial expert consultation questionnaire was constructed. Two rounds of expert consultation were conducted using the Delphi method to form the competency evaluation index system for clinical teachers in teaching hospitals. A hierarchy analysis was conducted using Python to calculate the weights of indicators.Results:The positive coefficients of the two rounds of expert consultation were 100.00% and 95.24%, respectively, and the expert authority coefficients were 0.843 and 0.862, respectively. The Kendall's coefficients of concordance for the first-, second-, and third-level indicators in the first round of expert consultation were 0.207, 0.152, and 0.191 ( P<0.001), respectively, and these coefficients in the second round of expert consultation were 0.271, 0.176, and 0.252 ( P<0.001), respectively. The final evaluation index system included 7 first-level indicators, 15 second-level indicators, and 43 third-level indicators. The first-level indicators included professional quality, professional knowledge and skills, medical education knowledge, teaching ability, communication and cooperation, teaching motivation, and career development, and their weights were 0.147, 0.149, 0.142, 0.147, 0.146, 0.134, and 0.136, respectively. Conclusions:The evaluation index system is comprehensive, scientific, and reliable. It can provide a reference for clinical teacher selection, evaluation, and training in teaching hospitals.
2.Construction of a competency evaluation index system for clinical teachers in teaching hospitals
Yuan ZHANG ; Zhihui ZOU ; Manjie ZHANG ; Zhiquan LIN ; Chuhong YU
Chinese Journal of Medical Education Research 2025;24(2):192-198
Objective:To construct a scientific and reliable clinical teacher competency evaluation index system, and provide a reference for strengthening the construction of clinical teachers in teaching hospitals.Methods:Based on literature research and group discussion, the initial expert consultation questionnaire was constructed. Two rounds of expert consultation were conducted using the Delphi method to form the competency evaluation index system for clinical teachers in teaching hospitals. A hierarchy analysis was conducted using Python to calculate the weights of indicators.Results:The positive coefficients of the two rounds of expert consultation were 100.00% and 95.24%, respectively, and the expert authority coefficients were 0.843 and 0.862, respectively. The Kendall's coefficients of concordance for the first-, second-, and third-level indicators in the first round of expert consultation were 0.207, 0.152, and 0.191 ( P<0.001), respectively, and these coefficients in the second round of expert consultation were 0.271, 0.176, and 0.252 ( P<0.001), respectively. The final evaluation index system included 7 first-level indicators, 15 second-level indicators, and 43 third-level indicators. The first-level indicators included professional quality, professional knowledge and skills, medical education knowledge, teaching ability, communication and cooperation, teaching motivation, and career development, and their weights were 0.147, 0.149, 0.142, 0.147, 0.146, 0.134, and 0.136, respectively. Conclusions:The evaluation index system is comprehensive, scientific, and reliable. It can provide a reference for clinical teacher selection, evaluation, and training in teaching hospitals.
3.The protective effect of cGAS/STING/IFN-Ⅰ signaling pathway mediating endothelial progenitor cells on atherosclerosis associated with systemic lupus erythematosus
Qiuyu LIN ; Siyi HE ; Lingjuan LIU ; Peng HUANG ; Lu ZHANG ; Sisi TAO ; Zhiquan XU ; Yi REN ; Shuanghong MO ; Hongai LI ; Wei XIANG ; Xiaojie HE
Journal of Chinese Physician 2024;26(12):1766-1772
Objective:To study the inhibitory effect of endothelial progenitor cells (EPCs) on aortic injury in mice with systemic lupus erythematosus (SLE) arteriosclerosis.Methods:APOE -/- mice were injected with norphytane and high fat diet to establish lupus vascular injury model. Then the mice were divided into normal control group (ND group), high fat diet group (HFD group), high fat diet+ SLE vascular injury group (HFD+ SLE group), high fat diet+ SLE vascular injury+ hydroxychloroquine treatment group (HFD+ SLE+ Hydro group), high fat diet+ SLE vascular injury+ EPCs treatment group (HFD+ SLE+ EPCs group). At the end of the experiment, urine, blood and aortic tissues of mice in each group were collected, and the content of urinary protein and the depth of serum type I interferon (IFN-Ⅰ) were detected by enzyme linked immunosorbent assay (ELISA). The activation of cyclic guanosine monophosphate synthase/interferon gene stimulating factor/type I interferon (cGAS/STING/IFN-Ⅰ) pathway, the levels of inflammatory factors, adhesion fractions and chemokines in the aorta of mice in each group were detected by immunohistochemistry and Western blotting (WB). The lipid deposition in the aorta was detected by oil red staining. Results:The results of ELISA showed that the levels of urinary protein and serum IFN-Ⅰ in HFD+ SLE group were higher than those in normal control group. EPCs treatment could reduce the levels of urinary protein and serum IFN-Ⅰ in SLE atherosclerotic mice. WB results showed that the expression of CD19, CD68, CD34, chemokine, cGAS, p-STING, phosphorylated TANK binding kinase 1 (p-TBK1), phosphorylated interferon regulatory factor 3 (p-IRF3) and IFN-Ⅰ increased in HFD+ SLE group, and hydroxychloroquine and EPCs decreased the levels of these factors. CGAS/STING/IFN-Ⅰ signal pathway is involved in the occurrence and development of atherosclerosis in SLE patients; both EPCs and hydroxychloroquine can inhibit the activation of cGAS/STING/IFN-Ⅰ signal, thus reducing atherosclerosis in SLE mice.Conclusions:cGAS/STING/IFN-Ⅰ pathway is involved in the development of SLE atherosclerosis. EPCs can inhibit the activation of cGAS/STING signal, reduce the expression and secretion of IFN-Ⅰ, and then reduce vascular inflammation and inhibit the development of SLE-related atherosclerosis.
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.The protective effect of cGAS/STING/IFN-Ⅰ signaling pathway mediating endothelial progenitor cells on atherosclerosis associated with systemic lupus erythematosus
Qiuyu LIN ; Siyi HE ; Lingjuan LIU ; Peng HUANG ; Lu ZHANG ; Sisi TAO ; Zhiquan XU ; Yi REN ; Shuanghong MO ; Hongai LI ; Wei XIANG ; Xiaojie HE
Journal of Chinese Physician 2024;26(12):1766-1772
Objective:To study the inhibitory effect of endothelial progenitor cells (EPCs) on aortic injury in mice with systemic lupus erythematosus (SLE) arteriosclerosis.Methods:APOE -/- mice were injected with norphytane and high fat diet to establish lupus vascular injury model. Then the mice were divided into normal control group (ND group), high fat diet group (HFD group), high fat diet+ SLE vascular injury group (HFD+ SLE group), high fat diet+ SLE vascular injury+ hydroxychloroquine treatment group (HFD+ SLE+ Hydro group), high fat diet+ SLE vascular injury+ EPCs treatment group (HFD+ SLE+ EPCs group). At the end of the experiment, urine, blood and aortic tissues of mice in each group were collected, and the content of urinary protein and the depth of serum type I interferon (IFN-Ⅰ) were detected by enzyme linked immunosorbent assay (ELISA). The activation of cyclic guanosine monophosphate synthase/interferon gene stimulating factor/type I interferon (cGAS/STING/IFN-Ⅰ) pathway, the levels of inflammatory factors, adhesion fractions and chemokines in the aorta of mice in each group were detected by immunohistochemistry and Western blotting (WB). The lipid deposition in the aorta was detected by oil red staining. Results:The results of ELISA showed that the levels of urinary protein and serum IFN-Ⅰ in HFD+ SLE group were higher than those in normal control group. EPCs treatment could reduce the levels of urinary protein and serum IFN-Ⅰ in SLE atherosclerotic mice. WB results showed that the expression of CD19, CD68, CD34, chemokine, cGAS, p-STING, phosphorylated TANK binding kinase 1 (p-TBK1), phosphorylated interferon regulatory factor 3 (p-IRF3) and IFN-Ⅰ increased in HFD+ SLE group, and hydroxychloroquine and EPCs decreased the levels of these factors. CGAS/STING/IFN-Ⅰ signal pathway is involved in the occurrence and development of atherosclerosis in SLE patients; both EPCs and hydroxychloroquine can inhibit the activation of cGAS/STING/IFN-Ⅰ signal, thus reducing atherosclerosis in SLE mice.Conclusions:cGAS/STING/IFN-Ⅰ pathway is involved in the development of SLE atherosclerosis. EPCs can inhibit the activation of cGAS/STING signal, reduce the expression and secretion of IFN-Ⅰ, and then reduce vascular inflammation and inhibit the development of SLE-related atherosclerosis.
9.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
BACKGROUND:
LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
METHODS:
We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
RESULTS:
On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
CONCLUSION:
LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04563936.
Humans
;
Male
;
Antineoplastic Agents, Hormonal/therapeutic use*
;
East Asian People
;
Gonadotropin-Releasing Hormone/agonists*
;
Goserelin/therapeutic use*
;
Prostate-Specific Antigen
;
Prostatic Neoplasms/drug therapy*
;
Testosterone
10.Evaluation of the effect of free fibular flap transplantation in repairing mandibular osteoradionecrosis defect in 151 cases
Qunxing LI ; Haotian CAO ; Yanyan LI ; Zhanpeng OU ; Xinyu LIN ; Hanqing ZHANG ; Zhaoyu LIN ; Youyuan WANG ; Shule XIE ; Chaobin PAN ; Bin ZHANG ; Jianguang WANG ; Weiliang CHEN ; Zhiquan HUANG ; Song FAN ; Jinsong LI
Chinese Journal of Stomatology 2021;56(5):428-434
Objective:To investigate the clinical effect of free fibula flap transplantation in repairing the defect of mandibular osteoradionecrosis (ORN).Methods:A total of 151 mandibular ORN patients undergoing free fibular flap transplantation were selected from August 2005 to September 2020 in the Department of Oral and Maxillofacial Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University. Among them, 109 patients were males and 42 patients were females, aged (54.1±10.1) (ranged 31-85) years old. The clinical data of the patients was collected and the survival rate of the flaps and postoperative function were calculated to evaluate the surgical efficacy. The χ 2 test was used for difference analysis. Results:Among the 151 patients, mandibular ORN caused by radiotherapy for nasopharyngeal carcinoma accounted for 79.5% (120/151). The average time for mandibular ORN appeared was 5(6) years after radiotherapy. Facial artery [57.2%(87/152)] and superior thyroid artery [32.9%(50/152)] were the main anastomotic arteries in the recipient area. There was no significant difference in the necrosis rates of the two flaps [10.3%(9/87) and 12.5% (5/50), respectively, P=0.949]. The main anastomotic veins in the recipient area were the external jugular vein [48.4%(135/279)] and the common facial vein [26.5%(74/279)]. Twenty-five cases (16.6%) had one vein anastomosed, and 126 cases (83.44%) had two veins anastomosed. There was no significant difference in the flap necrosis rate between the two conditions [20.0%(5/25) and 7.1%(9/126), respectively, P=0.100]. Ninety-seven cases (64.2%) used the peroneal musculocutaneous-fascia composite flap to repair the maxillofacial soft and hard tissue defects. Thirteen cases (8.6%) underwent the restorations with digital virtual surgery design, of which 5 cases were repaired with dental implants at the same time. After the operations, lower respiratory tract infection occurred in 17 patients (11.3%), and upper respiratory tract obstruction occurred in 3 cases (2.0%). The survival rate of the flap after operation was 90.7% (136/151), and 21 patients (13.9%) had flap vascular crisis. Delayed healing of maxillofacial wounds occurred in 33 cases (21.9%). After 3 to 24 months of follow-ups, 110 patients (76.9%) had no fistula inside/outside the oral cavity, 118 patients (82.5%) had an improvement in opening mouth of increasing (≥0.5 cm) after surgery, 135 patients (94.4%) had pain relief, 97 cases (67.8%) could eat normal diet, semi-liquid or soft food, and 137 cases (95.8%) were satisfied or basically satisfied with the treatment effects. Conclusions:The free fibular flap transplantation is an effective method to repair mandibular ORN defects. Preoperative vascular assessment is helpful for the selection of recipient vessels. Facial artery, superior thyroid artery, external jugular vein and common facial vein can be used as the main recipient vessels. The repair of the peroneal musculocutaneous-fascia composite flap facilitates the closure of internal and external fistulas. Digital technology can help to restore the maxillofacial shape more accurately, improve the patient′s occlusal and chewing function and enhance the quality of life of mandibular ORN patients.

Result Analysis
Print
Save
E-mail