1.Early assessment of responsive neurostimulation for drug-resistant epilepsy in China: A multicenter, self-controlled study.
Yanfeng YANG ; Penghu WEI ; Jianwei SHI ; Ying MAO ; Jianmin ZHANG ; Ding LEI ; Zhiquan YANG ; Shiwei SONG ; Ruobing QIAN ; Wenling LI ; Yongzhi SHAN ; Guoguang ZHAO
Chinese Medical Journal 2025;138(4):430-440
BACKGROUND:
To evaluate the efficacy and safety of the first cohort of people in China treated with a responsive neurostimulation system (Epilcure TM , GenLight MedTech, Hangzhou, China) for focal drug-resistant epilepsy in this study.
METHODS:
This multicenter, before-and-after self-controlled study was conducted across 8 centers from March 2022 to June 2023, involving patients with drug-resistant epilepsy who were undergoing responsive neurostimulation (RNS). The study was based on an ongoing multi-center, single-blind, randomized controlled study. Efficacy was assessed through metrics including median seizure count, seizure frequency reduction (SFR), and response rate. Multivariable linear regression analysis was conducted to explore the relationships of basic clinical factors and intracranial electrophysiological characteristics with SFR. The postoperative quality of life, cognitive function, depression, and anxiety were evaluated as well.
RESULTS:
The follow-up period for the 19 participants was 10.7 ± 3.4 months. Seizure counts decreased significantly 6 months after device activation, with median SFR of 48% at the 6th month (M6) and 58% at M12 ( P <0.05). The average response rate after 13 months of treatment was 42%, with 21% ( n = 4) of the participants achieving seizure freedom. Patients who have previously undergone resective surgery appear to achieve better therapeutic outcomes at M11, M12 and M13 ( β <0, P <0.05). No statistically significant differences were observed in patients' scores of quality of life, cognition, depression and anxiety following stimulation when compared to baseline measurements. No serious adverse events related to the devices were observed.
CONCLUSIONS:
The preliminary findings suggest that Epilcure TM exhibits promising therapeutic potential in reducing the frequency of epileptic seizures. However, to further validate its efficacy, larger-scale randomized controlled trials are required.
REGISTRATION
Chinese Clinical Trial Registry (No. ChiCTR2200055247).
Humans
;
Female
;
Male
;
Drug Resistant Epilepsy/therapy*
;
Adult
;
Young Adult
;
Middle Aged
;
China
;
Adolescent
;
Treatment Outcome
;
Quality of Life
;
Single-Blind Method
;
Seizures
;
Electric Stimulation Therapy/methods*
2.Impact of body mass index on postoperative complications of open pancreaticoduodenectomy
Yating ZHU ; Yiwei REN ; Zhiquan LIU ; Kunpeng LI ; Ran MIAO ; Xiangui HU ; Liu OUYANG
Chinese Journal of Pancreatology 2024;24(5):350-357
Objective:To investigate the impact of body mass index (BMI) on the postoperative complications of open pancreaticoduodenectomy (OPD).Methods:The preoperative, operative and postoperative data of 234 patients who underwent OPD in the Department of the Hepatobiliary and Pancreatic Surgery of First Affiliated Hospital affiliated to Naval Medical University from January 2015 to June 2016 were analyzed retrospectively. According to the Asian BMI standard, the patients were divided into three groups: underweight group (BMI<18.5 kg/m 2, n=32), normal weight group (18.5 kg/m 2≤BMI<23.0 kg/m 2, n=110) and overweight group (BMI≥23.0 kg/m 2, n=92). Normal weight group was compared with underweight group and overweight group, respectively, to analyze the relationship between BMI and intraoperative parameters and major postoperative complications of OPD. Results:The incidence of diabetes in underweight group was lower than that in normal weight group, and the proportion of ASA score 3 in underweight group was higher than that in normal weight group, and there were significantly statistical differences (both P value <0.05). There was no significant difference on the other variables between underweight group, normal weight group and overweight group. The operation time, intraoperative hemorrhage volume >800 ml and intraoperative blood transfusion rate were not statistically different between underweight group and normal weight group, but overweight group had obviously higher intraoperative blood transfusion rate than normal weight group and the difference was statistically significant ( P<0.05). Underweight group had more postoperative intraperitoneal hemorrhage and postoperative blood transfusion rate than normal weight group, and the readmission rate in underweight group was less than that in normal weight group; the incidence of clinically related-post operative pancreatic fistula, postoperative infection, gastrointestinal bleeding and delayed gastric emptying in overweight group were significantly higher than those in normal weight group, and there were significantly statistical differences (all P value <0.05). In underweight group, normal weight group and overweight group, the average length of hospital stay were 9.9 days, 11.3 days, 15 days, and the total hospitalization expenses were 63663.04 yuan, 66241.78 yuan and 80484.31 yuan, respectively. Conclusions:Compared to normal weight patients, the difficulty of OPD in underweight patients does not increase, while the difficulty of OPD in overweight patients increases. Underweight and overweight could both increase the postoperative complications of OPD to some extent.
3.Expert consensus on the treatment method of endoscopic assisted curettage for cystic lesions of the jaw bone
Wei WU ; Pan CHEN ; Zhiquan HUANG ; Guiquan ZHU ; Yue HE ; Chunjie LI ; Min RUAN ; Lizheng QIN ; Bing YAN ; Cheng WANG ; Jingzhou HU ; Zhijun SUN ; Guoxin REN ; Wei SHANG ; Kai YANG ; Jichen LI ; Moyi SUN
Journal of Practical Stomatology 2024;40(3):301-308
Curettage is the main treatment method for oral maxillofacial cystic lesions,but simple curettage may easily damage surrounding structures such as adjacent teeth and nerves,leading to incomplete removal of the cyst and large jaw defects.The curettage assisted by endoscopy can provide a good surgical field for the surgeons,can clearly identify the important anatomical structure during the operation and can remove the cyst wall tissue as much as possible,thereby reducing the damage and reducing the recurrence rate of the lesion.This article combines the characteristics of maxillofacial surgery with clinical treatment experience,summarizes relevant literature from both domestic and international sources,and engages in discussions with experts in order to provide reference for the clinical treatment of jaw cystic lesions with endo-scope assisted curettage.
4.Monitoring of wearable long-range ambulatory electrocardiographic monitor for a community-based homebound elderly population
Zhiquan YUAN ; Na WU ; Huiyan JIAO ; Chengying LI ; Long WU ; Meng NIE ; Yueyao XU ; Lei YANG ; Yu WANG ; Yonghong WU ; Li ZHONG ; Yafei LI
Journal of Army Medical University 2024;46(11):1316-1322
Objective To investigate the results of ambulatory electrocardiographic(ECG)monitoring in a community-based homebound elderly population and to explore the applicability of wearable long-range ambulatory ECG monitor for them.Methods Elderly volunteers were recruited in Shuangbei Community,Shapingba District,Chongqing,from November 2021 to June 2023.A single-lead wearable ambulatory ECG recorder was applied to them to obtain ECG for 7 consecutive days.The adverse reactions,acceptability,monitoring duration,and arrhythmia detection rate during the wearing were described and recorded.Serious arrhythmic events included frequent atrial premature,atrial flutter,atrial fibrillation(AF),frequent ventricular premature,and RR intervals ≥5 s.Results There were 416 individuals enrolled,with a mean age of 71.2±6.6 years,and a male percentage of 36.1%(150 men).Finally,384(92.3%)participants completed the wearing of the ECG monitor for 7 d,with an average time of 159.2±29.4 h.There were 179 participants(48.5%)reporting no discomfort during wearing,and 175 ones(47.4%)feeling itchy at the wearing site.The monitoring results showed that the common arrhythmias were atrial premature contractions(97.1%),premature ventricular contractions(93.3%),atrial tachycardia(84.6%),bradycardia(46.6%),frequent atrial premature contractions(15.1%),ventricular tachycardia(13.2%),and long RR interval(11.8%).Among them,29.1%of the participants experienced serious arrhythmic events,and the detection rate of certain serious arrhythmic events was comparatively higher in the individuals≥70 years of age and those with history of previous cardiac disease.Conclusion The detection rate of common arrhythmias is quite high in the community-based homebound elderly population.A 7-day long-range ambulatory ECG monitoring may be appropriate.
5.Trajectory of systolic blood pressure fluctuation and its influencing factors in community-dwelling patients with hypertension
Meng NIE ; Na WU ; Huiyan JIAO ; Zhiquan YUAN ; Chengying LI ; Long WU ; Yueyao XU ; Lei YANG ; Yu WANG ; Yonghong WU ; Li ZHONG ; Yafei LI ; Jingyuan YANG
Journal of Army Medical University 2024;46(12):1457-1466,封3
Objective To analyze and construct systolic blood pressure(SBP)fluctuation trajectory in a community population with hypertension and to analyze the factors influencing different trajectories.Methods This is a community-based retrospective cohort study.A latent class trajectory model was used to identify and construct longitudinal trajectories of blood pressure change.Multinomial logistic regression analysis was performed to identify the associated factors of blood pressure trajectories by adjusting for different confounders.Potential confounding factors were identified using a directed acyclic graph based on a priori knowledge.Results A total of 793 patients with hypertension were enrolled in the analysis.They were divided into 3 groups by LCTM-fitted systolic blood pressure trajectories,namely stable low-level group(n=561,70.74%),declining group(n=170,21.44%)and rising group(n=62,7.82%).Significant differences were observed among the 3 trajectories groups in terms of age,frequency of exercise,ways of follow-up,salt intake,compliance behavior,and referral(P<0.05).Compared to the stable low-level group and adjusting for corresponding confounding factors,the male patients and the patients with"outpatient follow-up"were more likely to be classified into"declining group",with OR and 95%CI of 1.436(1.016~2.030)and 1.702(1.202~2.410),respectively.The participants aged ≥ 65 years,who did not exercise or occasionally exercised,and had moderate and severe salt intake,were more likely to be classified into the"rising group"(OR=1.949,2.284,2.433,4.540,95%CI:1.145~3.317,1.305~3.998,1.272~4.654,1.291~15.963).Conclusion SBP trajectories in community-dwelling hypertensive population can be divided into stable low-level,declining and rising groups.Gender,age,salt intake,exercise frequency,and follow-up methods may be influencing factors for SBP blood pressure trajectory.
6.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
7.Construction of a whole business process supervision and management system: based on management information system of blood banks
Weidong HE ; Zhiquan RONG ; Chen XIAO ; Junlei HUANG ; Na HU ; Xuefeng LIANG ; Liyue JIANG ; Caina LI ; Wei WEI ; Yan LIU
Chinese Journal of Blood Transfusion 2024;37(4):455-461
【Objective】 To achieve supervision and management of the whole business process of blood center, raise productivity and ensure blood quality by enabling blood center managers comprehensively grasp the key business operation situation of the whole process at anytime and anywhere. 【Methods】 A whole business process supervision and management system was established covering background of preparation, business scope, content of position supervision and management, overall framework design, interface design of management and supervision management, physical database design, program development and online debugging, and was integrated with the blood bank management information system. The display and management were through a mobile APP to record key indicators of business process from blood collection to blood supply timely and comprehensively. Statistical analysis was conducted on total collection volume, total preparation volume and total supply volume, as well as discarding rate of test unqualified and of non-test unqualified (lipemic blood excluded) in 2023 and 2022. 【Results】 We established a mobile APP based on a blood bank management information system for business supervision and management of whole process, and achieved management by phones. After its implementation in 2023, the total collection volume, total preparation volume and total supply volume in 2023 were all higher than those in 2022, with growth rates of 5.88% (13 247/225 454 U), 4.73% (24 156/510 698 U), and 6.70% (34 814/519 914 U), respectively. The discarding rate in 2023 was lower than that in 2022 (0.54%, 2 868/534 854 U) vs (0.60%, 3 047/510 698 U) (P<0.01), and the non-test unqualified discarding rate (lipemic blood excluded) in 2023 was significantly lower than that in 2022(0.12%, 649/534 854 U) vs (0.19%, 991/510 698 U)(P<0.01). 【Conclusion】 The construction of supervision and management system of a whole business process based on blood bank management information system can meet the standardized service needs of managers at anytime and anywhere, continuously raise productivity and the standardization and scientific level of blood bank management, thus ensuring blood supply.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail