1.Integrated imaging and clinical features of glottic squamous cell carcinoma of the larynx: pathological association and prognosis assessment.
Yuqiao ZHANG ; Wulin WEN ; Fengxia YANG ; Dongke MA ; Xueliang SHEN ; Ningyu FENG ; Xixi LI ; Zhiling ZENG ; Zhipeng MI ; Xiyuan YAN ; Ruixia MA
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(8):709-716
Objective:To explore the clinical, imaging, and pathological features of glottic squamous cell carcinoma of the larynx and their relationship with prognosis. Methods:A retrospective analysis was conducted on the clinical, imaging, and pathological data of 130 patients with glottic squamous cell carcinoma of the larynx who were treated at the First People's Hospital of Yinchuan and the General Hospital of Ningxia Medical University from January 2018 to March 2023. Imaging examinations (CT and MRI) were used to evaluate the lesion boundary clarity, density, enhancement nature, and enhancement degree. Postoperative pathological examination was used to determine the pathological nature, immunohistochemistry, etc. Statistical methods such as χ² test, Spearman correlation analysis, multivariate logistic regression analysis, and Kaplan-Meier method were used to analyze the data. Results:Among the 130 patients, 127 were male and 3 were female, with an average age of (61.92±9.595) years. There was a correlation between clinical, imaging, and pathological features. Multivariate analysis showed that heterogeneous MRI density (OR=12.414;P=0.019) and squamous cell carcinoma as a subtype were correlated. The initial symptom of non-hoarseness (HR=6.045;P=0.010) and unclear MRI boundary (HR=12.559; P=0.029) were independent risk factors for poor prognosis in patients with glottic squamous cell carcinoma of the larynx. Conclusion:There is a correlation between the clinical, imaging, and pathological features of patients with glottic squamous cell carcinoma of the larynx, and they can affect prognosis. The initial symptom of non-hoarseness and unclear MRI boundary of the tumor are independent risk factors for poor prognosis.
Humans
;
Laryngeal Neoplasms/diagnosis*
;
Prognosis
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Carcinoma, Squamous Cell/diagnosis*
;
Magnetic Resonance Imaging
;
Glottis/pathology*
;
Tomography, X-Ray Computed
;
Aged
2.Impact of the number of microsatellite markers on the analysis of population genetic diversity of Schistosoma japonicum
Juan LONG ; Lang MA ; Hongying ZONG ; Zhipeng ZHOU ; Hao YAN ; Qinping ZHAO
Chinese Journal of Schistosomiasis Control 2025;37(3):239-246
Objective To examine the impact of different numbers of microsatellite markers on the analysis of population genetic diversity of Schistosoma japonicum, so as to provide insights into studies on the population genetic diversity of S. japonicum. Methods Oncomelania hupensis snails were collected from a wasteland in Gong’an County, Hubei Province, and 37 S. japonicum-infected O. hupensis snails were identified using the cercarial shedding method. A single cercaria released from each S. japonicum-infected O. hupensis snail was collected, and 10 cercariae were randomly collected from DNA extraction. Nine previously validated microsatellite loci and 15 additional microsatellite loci screened from literature review and the GenBank database and confirmed with stable amplification efficiency were selected as molecular markers. Genomic DNA from cercariae was subjected to three multiplex PCR amplifications of microsatellite markers with the Type-it Microsatellite PCR kit, and genotyped using capillary electrophoresis. The population genetic diversity of S. japonicum cercariae DNA was analyzed with observed number of alleles (Na), effective number of alleles (Ae), observed heterozygosity (Ho), expected heterozygosity (He), and polymorphism information content (PIC), and tested for Hardy-Weinberg equilibrium (HWE) and linkage disequilibrium (LD). To further investigate the impact of the number of microsatellite loci on the population genetic diversity of S. japonicum, the number of microsatellite markers was sequentially assigned from 1 to 24, and the mean and standard deviation of Na were calculated for S. japonicum populations at different locus numbers. In addition, the coefficient of variation (CV) of allelic number (defined as the ratio of the standard deviation to the mean) was determined, and the variation in Na with increasing microsatellite locus numbers was analyzed. Results Genomic DNA from 345 S. japonicum cercariae was selected for genotyping of 24 microsatellite markers, and all 24 microsatellite loci met linkage equilibrium (standardized linkage disequilibrium coefficient D′ < 0.7, r2 < 0.3) and deviated from Hardy-Weinberg equilibrium (P < 0.001). The mean Na, Ae, Ho and He were 27.46 ± 2.18, 12.46 ± 0.95, 0.46 ± 0.03, and 0.91 ± 0.01 for 24 microsatellite loci in S. japonicum cercarial populations, respectively, and PIC ranged from 0.85 to 0.96, indicating high genome-wide representativeness of 24 microsatellite loci. The mean value of Na-Ae was higher in genotyping with 9 previously validated microsatellite loci (19.88 ± 8.43) than with all 24 loci (14.99 ± 8.09). As the number of microsatellite loci increased, the mean Na showed no significant variation; however, the standard deviation gradually decreased. Notably, if the locus number reached 18 or more, the variation in the standard deviation of Na remarkably reduced. In addition, the standard deviation of Na at 18 loci was less than 5% of the mean Na at 24 loci, with a CV of 4.6%. Conclusions The number of microsatellite loci significantly affects the population genetic diversity analysis of S. japonicum. Eighteen or more microsatellite loci are recommended for analysis of the population genetic diversity of S. japonicum under the current conditions of low-prevalence infection and unbalanced genetic distribution of S. japonicum.
3.Research progress of emotion recognition based on electroencephalogram signal
Kunqi DAI ; Ren MA ; Tao YIN ; Zhipeng LIU
International Journal of Biomedical Engineering 2025;48(5):482-488
Emotion is defined as a physiological and psychological state that encompasses human thoughts, behaviors, and feelings. This phenomenon is also regarded as a spontaneous physiological and psychological response generated by the human body to external stimuli. Given the established correlation between electroencephalogram signal and cerebral activity, it is possible to extrapolate the emotional state of subjects by means of electroencephalogram signal analysis. In this review, emotion models, datasets, and popular machine learning and deep learning methods in recent years used in emotion recognition research were summarized. In addition, the research progress of emotion recognition based on electroencephalogram signal was reviewed, with the aim of assisting subsequent researchers in understanding developments in electroencephalogram signal domain and offering insights for addressing clinical challenges in emotion recognition.
4.A multi-parameter morning check method for pencil-beam scanning proton therapy
Chao SHAN ; Zhipeng LIU ; Yangfan ZHANG ; Yanmei ZHANG ; Tao MA ; Hongyu ZHAO ; Tao SUN ; Xiaoming LU
Chinese Journal of Radiation Oncology 2025;34(7):692-696
Objective:To design a morning quality assurance method for pencil-beam scanning proton system to achieve integrated measurement of multiple parameters.Methods:A functionally partitioned morning check phantom was designed and manufactured, which was fixed to a specific position on the treatment bed with a 3D-printed clip, along with the two-dimensional matrix ionization chamber, for consistency checks of proton field and beam-related parameters. Additionally, a groove for an imaging phantom was reserved on one side of the clip for the functional check of the onboard imaging guidance system. The sensitivity and specificity of the aforementioned morning check method were tested, demonstrating its effectiveness. The morning check data from a rotating beam treatment room at the Hefei Ion Medical Center over a continuous period of 7 months (126 d) were analyzed. The output, field flatness, symmetry, field size and the duration of morning check were observed.Results:The results showed that the changes in the output, field flatness, and symmetry were all within 1%, the change in the field size was within 0.5 mm, and the range variations for both 155 MeV and 240 MeV energy levels were within 1 mm. The changes in the spot size for the four energy levels of 100 MeV, 130 MeV, 160 MeV, and 190 MeV were all within 2%, and the spot position deviations were within 1.5 mm. The entire morning check process could be completed within 20 min.Conclusions:The morning check method designed and manufactured in this study specifically for pencil-beam scanning proton therapy can efficiently and integrally measure various proton system parameters and can be used as an implementation method for clinical proton therapy morning check.
5.Three-dimensional radiographic features of solid variant of odontogenic keratocyst
Huasen MA ; Junru ZHAO ; Yubing LI ; Chang HAN ; Yangjing SONG ; Yan CHEN ; Zhipeng SUN ; Gang LI
Journal of Practical Stomatology 2025;41(2):168-172
Objective:To analyze the three-dimensional radiographic characteristics of solid variant of odontogenic keratocyst(SOKC)using multi-slice spiral tomography(MSCT).Methods:Clinical records,histopathological reports and MSCT images of 8 patients were retrospectively acquired,radiographic features,including lesion site,size,borders,jaw expansion,internal structures and relationship with surrounding tissues were analyzed.Results:8 cases(4 males and 4 females)aged 37-65 years were included.Among them,4 lesions were located in the maxilla and the other 4 in mandible.Clinically,the lesions manifested as an enlargement of the affected area in the jaw bone,with pain present in 6 cases.On MSCT scans,all lesions showed evident jaw expansion.The boundaries of the lesions were clear in 3 cases,and unclear in 5 cases.4 cases exhibited multilocular radiolucent lesions,while the other 4 cases showed mixed radiolucent/opaque lesions resembling fibro-osseous lesion.The maxilla lesions involved the palate,na-sal cavity,maxillary sinus and orbital floor.All mandible SOKCs were recurrent and infectious,with involvement of the surrounding soft tissue.Conclusion:SOKC exhibits imaging characteristics that differentiate from conventional odontogenic keratocysts.Radio-graphically,it presents as a benign or low-grade malignant solid jaw mass.
6.Three-dimensional radiographic features of solid variant of odontogenic keratocyst
Huasen MA ; Junru ZHAO ; Yubing LI ; Chang HAN ; Yangjing SONG ; Yan CHEN ; Zhipeng SUN ; Gang LI
Journal of Practical Stomatology 2025;41(2):168-172
Objective:To analyze the three-dimensional radiographic characteristics of solid variant of odontogenic keratocyst(SOKC)using multi-slice spiral tomography(MSCT).Methods:Clinical records,histopathological reports and MSCT images of 8 patients were retrospectively acquired,radiographic features,including lesion site,size,borders,jaw expansion,internal structures and relationship with surrounding tissues were analyzed.Results:8 cases(4 males and 4 females)aged 37-65 years were included.Among them,4 lesions were located in the maxilla and the other 4 in mandible.Clinically,the lesions manifested as an enlargement of the affected area in the jaw bone,with pain present in 6 cases.On MSCT scans,all lesions showed evident jaw expansion.The boundaries of the lesions were clear in 3 cases,and unclear in 5 cases.4 cases exhibited multilocular radiolucent lesions,while the other 4 cases showed mixed radiolucent/opaque lesions resembling fibro-osseous lesion.The maxilla lesions involved the palate,na-sal cavity,maxillary sinus and orbital floor.All mandible SOKCs were recurrent and infectious,with involvement of the surrounding soft tissue.Conclusion:SOKC exhibits imaging characteristics that differentiate from conventional odontogenic keratocysts.Radio-graphically,it presents as a benign or low-grade malignant solid jaw mass.
7.A multi-parameter morning check method for pencil-beam scanning proton therapy
Chao SHAN ; Zhipeng LIU ; Yangfan ZHANG ; Yanmei ZHANG ; Tao MA ; Hongyu ZHAO ; Tao SUN ; Xiaoming LU
Chinese Journal of Radiation Oncology 2025;34(7):692-696
Objective:To design a morning quality assurance method for pencil-beam scanning proton system to achieve integrated measurement of multiple parameters.Methods:A functionally partitioned morning check phantom was designed and manufactured, which was fixed to a specific position on the treatment bed with a 3D-printed clip, along with the two-dimensional matrix ionization chamber, for consistency checks of proton field and beam-related parameters. Additionally, a groove for an imaging phantom was reserved on one side of the clip for the functional check of the onboard imaging guidance system. The sensitivity and specificity of the aforementioned morning check method were tested, demonstrating its effectiveness. The morning check data from a rotating beam treatment room at the Hefei Ion Medical Center over a continuous period of 7 months (126 d) were analyzed. The output, field flatness, symmetry, field size and the duration of morning check were observed.Results:The results showed that the changes in the output, field flatness, and symmetry were all within 1%, the change in the field size was within 0.5 mm, and the range variations for both 155 MeV and 240 MeV energy levels were within 1 mm. The changes in the spot size for the four energy levels of 100 MeV, 130 MeV, 160 MeV, and 190 MeV were all within 2%, and the spot position deviations were within 1.5 mm. The entire morning check process could be completed within 20 min.Conclusions:The morning check method designed and manufactured in this study specifically for pencil-beam scanning proton therapy can efficiently and integrally measure various proton system parameters and can be used as an implementation method for clinical proton therapy morning check.
8.A blood glucose fluctuation-responsive delivery system promotes bone regeneration and the repair function of Smpd3-reprogrammed BMSC-derived exosomes.
Lingxiao WANG ; Haoqing YANG ; Chen ZHANG ; Yue ZHANG ; Yilin HE ; Yang LIU ; Pan MA ; Jun LI ; Zhipeng FAN
International Journal of Oral Science 2024;16(1):65-65
Blood glucose fluctuation leads to poor bone defect repair in patients with type 2 diabetes (T2DM). Strategies to safely and efficiently improve the bone regeneration disorder caused by blood glucose fluctuation are still a challenge. Neutral sphingophospholipase 2 (Smpd3) is downregulated in jawbone-derived bone marrow mesenchymal stem cells (BMSCs) from T2DM patients. Here, we investigated the effect of Smpd3 on the osteogenic differentiation of BMSCs and utilized exosomes from stem cells overexpressing Smpd3 as the main treatment based on the glucose responsiveness of phenylboronic acid-based polyvinyl alcohol crosslinkers and the protease degradability of gelatin nanoparticles. The combined loading of Smpd3-overexpressing stem cell-derived exosomes (Exos-Smpd3) and nanosilver ions (Ns) to construct a hydrogel delivery system (Exos-Smpd3@Ns) promoted osteogenesis and differentiation of BMSCs in a glucose-fluctuating environment, ectopic osteogenesis of BMSCs in a glucose-fluctuating environment and jawbone regeneration of diabetic dogs in vitro. Mechanistically, Smpd3 promoted the osteogenesis and differentiation of jawbone-derived BMSCs by activating autophagy in the jawbone and inhibiting macrophage polarization and oxidative stress caused by blood glucose fluctuations. These results reveal the role and mechanism of Smpd3 and the Smpd3 overexpression exosome delivery system in promoting BMSC function and bone regeneration under blood glucose fluctuations, providing a theoretical basis and candidate methods for the treatment of bone defects in T2DM patients.
Exosomes
;
Animals
;
Bone Regeneration/drug effects*
;
Dogs
;
Mesenchymal Stem Cells
;
Humans
;
Blood Glucose
;
Cell Differentiation
;
Osteogenesis/drug effects*
;
Diabetes Mellitus, Type 2/therapy*
;
Diabetes Mellitus, Experimental
;
Cells, Cultured
;
Hydrogels
;
Male
9.A blood glucose fluctuation-responsive delivery system promotes bone regeneration and the repair function of Smpd3-reprogrammed BMSC-derived exosomes
Lingxiao WANG ; Haoqing YANG ; Chen ZHANG ; Yue ZHANG ; Yilin HE ; Yang LIU ; Pan MA ; Jun LI ; Zhipeng FAN
International Journal of Oral Science 2024;16(4):782-796
Blood glucose fluctuation leads to poor bone defect repair in patients with type 2 diabetes(T2DM).Strategies to safely and efficiently improve the bone regeneration disorder caused by blood glucose fluctuation are still a challenge.Neutral sphingophospholipase 2(Smpd3)is downregulated in jawbone-derived bone marrow mesenchymal stem cells(BMSCs)from T2DM patients.Here,we investigated the effect of Smpd3 on the osteogenic differentiation of BMSCs and utilized exosomes from stem cells overexpressing Smpd3 as the main treatment based on the glucose responsiveness of phenylboronic acid-based polyvinyl alcohol crosslinkers and the protease degradability of gelatin nanoparticles.The combined loading of Smpd3-overexpressing stem cell-derived exosomes(Exos-Smpd3)and nanosilver ions(Ns)to construct a hydrogel delivery system(Exos-Smpd3@Ns)promoted osteogenesis and differentiation of BMSCs in a glucose-fluctuating environment,ectopic osteogenesis of BMSCs in a glucose-fluctuating environment and jawbone regeneration of diabetic dogs in vitro.Mechanistically,Smpd3 promoted the osteogenesis and differentiation of jawbone-derived BMSCs by activating autophagy in the jawbone and inhibiting macrophage polarization and oxidative stress caused by blood glucose fluctuations.These results reveal the role and mechanism of Smpd3 and the Smpd3 overexpression exosome delivery system in promoting BMSC function and bone regeneration under blood glucose fluctuations,providing a theoretical basis and candidate methods for the treatment of bone defects in T2DM patients.
10.Effects of distal tibial tuberosity-high tibial osteotomy on ankle angle on coronal plane
Yuetong YIN ; Guangyu ZHU ; Xiangdong TIAN ; Yetong TAN ; Sheng MA ; Zhipeng XUE ; Yuanyi HU ; Xiaomin LI
Chinese Journal of Tissue Engineering Research 2024;28(21):3349-3354
BACKGROUND:Distal tibial tuberosity-high tibial osteotomy is a surgical treatment for knee osteoarthritis,but there is still a lack of clinical studies on its effect on ankle joints. OBJECTIVE:To observe the effects of distal tibial tuberosity-high tibial osteotomy on ankle angle on coronal plane of the radiography of the full length of lower limb in weight loading. METHODS:Data of 40 patients(41 knees)with distal tibial tuberosity-high tibial osteotomy from March 2021 to March 2022 were retrospectively analyzed,including 31 females and 9 males,20 left knees and 21 right knees,aged 49-75 years,mean(63.44±6.57)years.The radiographic data of the full length of the lower limb in weight loading were collected before,week 2 and week 48 postoperatively.Hip-knee-ankle angle,talar tilt angle,tilt angle of the ankle,tibiocrural angle,and tibial articular surface angle were measured before and after surgery. RESULTS AND CONCLUSION:(1)Hip-knee-ankle angle improved from(-6.24±3.69)° before operation to(2.59±3.49)° week 2 postoperatively and(2.15±3.49)° week 48 postoperatively.The tilt angle of the ankle changed from(-7.90±3.11)° before operation to(-2.51±2.59)° week 2 postoperatively and(-2.46±2.42)° week 48 postoperatively,with statistically significant difference(P<0.001).(2)There was no significant difference in talar tilt angle,tibiocrural angle,and tibial articular surface angle before and week 2 postoperatively.(3)No significant difference in the angle changes was detected between week 2 and week 48 postoperatively.(4)It is indicated that distal tibial tuberosity-high tibial osteotomy can not only correct genu varus but also improve ankle angle.This result remains stable after 48 weeks of weight-bearing activities.

Result Analysis
Print
Save
E-mail