1.Effects of β-sitosterol on proliferation and apoptosis of colon cancer cell HCT116
Xi CHEN ; Ruonan LI ; Jing LI ; Lina ZHAO ; Zhili XU
China Modern Doctor 2024;62(9):78-81,85
Objective To investigate the effects of β-sitosterol on the proliferation and apoptosis of colon cancer cell HCT116,and its regulation of on phosphoinositide 3-kinase/protein kinase B(PI3K/Akt)signaling pathway.Methods Cultivated colon cancer cells HCT116 in vitro and divided them into β-sitosterol High(240μmol/L)、medium(120μmol/L)and low-dose(60μmol/L)groups,set control group(0μmol/L).Applied different concentrations of β-sitosterol treatment of HCT116 cells.And 24h later,the cell proliferation and activity were determined by cell counting kit-8(CCK-8)method,the morphological changes observed under a microscope;Cell apoptosis was observed by Hoechst 33342 nuclear staining;Used cell colony formation assy to detect the colony forming ability of HCT116 cells;and Western blot was used to evaluate the expression of PI3K,p-Akt,Akt,Bcl-2 and Bax in cells.Used AutoDock software for molecular docking of β-sitosterol with Akt and PI3K.Results Compared with the control group,β-sitosterol could inhibit the proliferation of colon cancer HCT116 cells in a concentration dependent manner,inhibit their colony forming ability and promote cell apoptosis and inhibit the expression of p-Akt、PI3K、and Bcl-2 proteins in HCT116 cells and promotes the expression of Bax protein.The binding of β-sitosterol with PI3K and Akt proteins is relatively stable.Conclusion β-sitosterol may regulate the proliferation and apoptosis of HCT116 through inhibiting PI3K/Akt signaling pathway.
2.Dynamic ultrasound combined with 3.0T MRI for diagnosing and typing of synovial plica of knee joint
Nan LI ; Zhili WANG ; Danfeng XU ; Yan JIAO ; Ruisong SHANG
Chinese Journal of Medical Imaging Technology 2024;40(2):275-279
Objective To explore the value of dynamic ultrasound combined with 3.0T MRI for diagnosing and typing synovial plica of knee joint.Methods Dynamic ultrasound and 3.0T MRI data of 100 patients with suspected synovial plica of knee joint were retrospectively analyzed.Taking the results of arthroscopy as standards,the efficacy of dynamic ultrasound and 3.0T MRI alone and their combination for diagnosing synovial plica of knee joint were evaluated and compared.The length and thickness of synovial plica of knee joint measured with dynamic ultrasound,3.0T MRI alone and their combination were compared with those of arthroscopy,and the consistencies of the location and classification of synovial plica of knee joint with arthroscopy were analyzed.Results Synovial plica was detected in 70 cases,including 11 cases of supropatellar synovial plica,15 cases of infrapatellar synovial plica,medial patellar in 30 cases and lateral patellar synovial plica in 14 cases,among them type A,B,C and D were classified in 9,35,23 and 3 cases,respectively.No significant difference of sensitivity was found between dynamic ultrasound and 3.0T MRI alone for diagnosing synovial plica of knee joint(P>0.05),which were both lower than that of their combination(both P<0.05).The length and thickness of knee synovial plica measured with dynamic ultrasound and 3.0T MRI alone were lower than those measured with their combination and arthroscopy(all P<0.05),and there was no significant difference between the results of their combination and arthroscopy(both P>0.05).Dynamic ultrasound,3.0T MRI alone and their combination had high consistency of location(Kappa=0.755,0.826,0.897)and classification of knee synovial plica with those of arthroscopy(Kappa=0.721,0.744,0.860).Conclusion Dynamic ultrasound combined with 3.0T MRI was valuable for diagnosing and typing of synovial plica of knee joint.
3.Research on the application of non-contact physiological and psychological detection in the analysis of long-term simulated weightlessness effects
Shuai DING ; Zi XU ; Qian RONG ; Shujuan LIU ; Zihao LIU ; Yuan WU ; Yao YU ; Zhili LI ; Cheng SONG ; Lina QU ; Hao WANG ; Yinghui LI
Space Medicine & Medical Engineering 2024;35(2):78-83,98
Objective Explore a non-contact physiological and psychological detection model based on facial video in simulations of weightlessness effects,research new methods for non-contact heart rate and negative mood state detection in long-term simulations of weightlessness effect analysis.Methods Construct a non-contact physiological and psychological data collection system for fusion analysis of visible light and thermal infrared videos.Collect physiological and psychological data of volunteers in the"Earth Star-Ⅱ"90-day head-down bed rest experiment.A non-contact heart rate detection model based on GCN facial multi-region feature fusion and a non-contact negative mood state detection model considering data reliability were constructed,and the effectiveness of the models were validated with finger clip heart rate and POMS-SF scale as labels.Results The experimental results show that the average difference in the Bland-Altman plot of the non-contact heart rate detection model is-1.26 bpm,and 96.3%of value error detection data falls within the 95%confidence interval,indicating a high consistency between the model detected heart rate and the finger clip heart rate.The non-contact negative mood state detection model achieves an accuracy of>0.85 for detecting tension,depression,anger,and fatigue.Features such as heart rate,AU06,eye gaze,and head pose were observed to be important to mood state detection.Conclusion Non-contact physiological and psychological detection methods not only can be utilized for long-term physiological analysis in simulations of weightlessness effects,but also provide a novel technical approach for on-orbit astronauts health assurance during long-term space flight in the future.
4.Development of a national health standard:Guideline for pediatric transfusion
Rong HUANG ; Qingnan HE ; Mingyan HEI ; Minghua YANG ; Xiaofan ZHU ; Jun LU ; Xiaojun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jinping LIU ; Jing WANG ; Zhili SHAO ; Mingyi ZHAO ; Jia GUO ; Xiny-In WU ; Jiarui CHEN ; Qirong CHEN ; Rong GUI ; Yongjian GUO
Chinese Journal of Blood Transfusion 2024;37(7):839-844
Children and adults differ significantly in physiology,biochemistry and immune function,which leads to sig-nificant differences in blood transfusion strategies between children and adults.To guide the clinical transfusion practice of pediatric patients and improve the prognosis of children,the National Health Commission organized the formulation and re-lease of the health industry standard Guideline for Pediatric Transfusion(WS/T 795-2022).This paper will briefly introduce some concepts that help understand of the Standard and the preparation process of the Standard,and explain and interpret the preparation of the"scope","general provisions"and"factors to consider"of the Standard,hoping to contribute to the understanding and implementation of the Standard.
5.Bladder microenvironment actuated proteomotors with ammonia amplification for enhanced cancer treatment.
Hao TIAN ; Juanfeng OU ; Yong WANG ; Jia SUN ; Junbin GAO ; Yicheng YE ; Ruotian ZHANG ; Bin CHEN ; Fei WANG ; Weichang HUANG ; Huaan LI ; Lu LIU ; Chuxiao SHAO ; Zhili XU ; Fei PENG ; Yingfeng TU
Acta Pharmaceutica Sinica B 2023;13(9):3862-3875
Enzyme-driven micro/nanomotors consuming in situ chemical fuels have attracted lots of attention for biomedical applications. However, motor systems composed by organism-derived organics that maximize the therapeutic efficacy of enzymatic products remain challenging. Herein, swimming proteomotors based on biocompatible urease and human serum albumin are constructed for enhanced antitumor therapy via active motion and ammonia amplification. By decomposing urea into carbon dioxide and ammonia, the designed proteomotors are endowed with self-propulsive capability, which leads to improved internalization and enhanced penetration in vitro. As a glutamine synthetase inhibitor, the loaded l-methionine sulfoximine further prevents the conversion of toxic ammonia into non-toxic glutamine in both tumor and stromal cells, resulting in local ammonia amplification. After intravesical instillation, the proteomotors achieve longer bladder retention and thus significantly inhibit the growth of orthotopic bladder tumor in vivo without adverse effects. We envision that the as-developed swimming proteomotors with amplification of the product toxicity may be a potential platform for active cancer treatment.
6.KCTD4 interacts with CLIC1 to disrupt calcium homeostasis and promote metastasis in esophageal cancer.
Cancan ZHENG ; Xiaomei YU ; Taoyang XU ; Zhichao LIU ; Zhili JIANG ; Jiaojiao XU ; Jing YANG ; Guogeng ZHANG ; Yan HE ; Han YANG ; Xingyuan SHI ; Zhigang LI ; Jinbao LIU ; Wen Wen XU
Acta Pharmaceutica Sinica B 2023;13(10):4217-4233
Increasing evidences suggest the important role of calcium homeostasis in hallmarks of cancer, but its function and regulatory network in metastasis remain unclear. A comprehensive investigation of key regulators in cancer metastasis is urgently needed. Transcriptome sequencing (RNA-seq) of primary esophageal squamous cell carcinoma (ESCC) and matched metastatic tissues and a series of gain/loss-of-function experiments identified potassium channel tetramerization domain containing 4 (KCTD4) as a driver of cancer metastasis. KCTD4 expression was found upregulated in metastatic ESCC. High KCTD4 expression is associated with poor prognosis in patients with ESCC and contributes to cancer metastasis in vitro and in vivo. Mechanistically, KCTD4 binds to CLIC1 and disrupts its dimerization, thus increasing intracellular Ca2+ level to enhance NFATc1-dependent fibronectin transcription. KCTD4-induced fibronectin secretion activates fibroblasts in a paracrine manner, which in turn promotes cancer cell invasion via MMP24 signaling as positive feedback. Furthermore, a lead compound K279-0738 significantly suppresses cancer metastasis by targeting the KCTD4‒CLIC1 interaction, providing a potential therapeutic strategy. Taken together, our study not only uncovers KCTD4 as a regulator of calcium homeostasis, but also reveals KCTD4/CLIC1-Ca2+-NFATc1-fibronectin signaling as a novel mechanism of cancer metastasis. These findings validate KCTD4 as a potential prognostic biomarker and therapeutic target for ESCC.
7.A novel inhibitor of ARfl and ARv7 induces protein degradation to overcome enzalutamide resistance in advanced prostate cancer.
Yan LI ; Ya CHU ; Guangjiang SHI ; Xiaobin WANG ; Wanli YE ; Chun SHAN ; Dajia WANG ; Di ZHANG ; Wei HE ; Jingwei JIANG ; Shuqian MA ; Yuhong HAN ; Zhili ZHAO ; Shijia DU ; Zhen CHEN ; Zhiyu LI ; Yong YANG ; Chen WANG ; Xi XU ; Hongxi WU
Acta Pharmaceutica Sinica B 2022;12(11):4165-4179
Enzalutamide (ENZ) is a second-generation androgen receptor (AR) antagonist used for the treatment of castration-resistant prostate cancer (CRPC) and reportedly prolongs survival time within a year of starting therapy. However, CRPC patients can develop ENZ resistance (ENZR), mainly driven by abnormal reactivation of AR signaling, involving increased expression of the full-length AR (ARfl) or dominantly active androgen receptor splice variant 7 (ARv7) and ARfl/ARv7 heterodimers. There is currently no efficient treatment for ENZR in CRPC. Herein, a small molecule LLU-206 was rationally designed based on the ENZ structure and exhibited potent inhibition of both ARfl and constitutively active ARv7 to inhibit PCa proliferation and suppress ENZR in CRPC. Mechanically, LLU-206 promoted ARfl/ARv7 protein degradation and decreased ARfl/ARv7 heterodimers through mouse double minute 2-mediated ubiquitination. Finally, LLU-206 exhibited favorable pharmacokinetic properties with poor permeability across the blood-brain barrier, leading to a lower prevalence of adverse effects, including seizure and neurotoxicity, than ENZ-based therapies. In a nutshell, our findings demonstrated that LLU-206 could effectively inhibit ARfl/ARv7-driven CRPC by dual-targeting of ARfl/ARv7 heterodimers and protein degradation, providing new insights for the design of new-generation AR inhibitors to overcome ARfl/ARv7-driven CRPC.
8.Correlation between the characteristics of motor evoked potential and severity of spinal cord injury in patients with acute cervical hyperextension injury and central spinal cord syndrome
Lijuan ZHAO ; Jianjie WANG ; Chunya GU ; Yuhui CHEN ; Zhili ZENG ; Ning XIE ; Bin MA ; Yan YU ; Wei XU ; Xiao HU ; Yilong REN ; Liming CHENG
Chinese Journal of Orthopaedic Trauma 2022;24(7):570-576
Objective:To study the correlation between the acute-phase characteristics of motor evoked potential (MEP) and severities of spinal cord injury in patients with acute cervical hyperextension injury and central cord syndrome (CCS).Methods:Retrospectively analyzed were the data of 45 patients with acute cervical hyperextension injury and CCS (observation group) who had been admitted to Department of Orthopedics, Tongji Hospital Affiliated to Tongji University from December 2018 to July 2021 and 20 healthy controls. Examination of transcranial magnetic stimulation-induced MEP was performed in patients with CCS and healthy controls using a magpro x100 magnetic stimulator, and recording was conducted in bilateral abductor pollicis brevis (APB). The characteristics of MEP waveform latency, amplitude and motor threshold were described and compared between the healthy control and observation groups; the correlations were analyzed between the MEP latency and the severity of spinal cord injury [American Spinal Injury Association (ASIA) total score and motor function of Upper Extremity Motor Subscores (UEMS)] in the observation group. According to different MEP-induced states, the patients in the observation group were divided into a resting group ( n=19), a facilitation group ( n=18), and a no-waveform group ( n=8). The severity of spinal cord injury (ASIA total score) and the functional independence of the spinal cord (SCIM-Ⅲ score) were compared among the 3 groups to analyze the correlation between the MEP-induced state and the severity of spinal cord injury (ASIA total score). Results:The observation group had a significantly longer MEP latency [(30.16±6.32) ms], a significantly smaller amplitude [(0.54±0.30) mV] and a significantly higher motor threshold [(65%±11%)] than the healthy control group (all P<0.05). The MEP latency in the observation group was significantly correlated with ASIA total score ( r=-0.730, P<0.001) and UEMS ( r=-0.740, P<0.001). The ASIA total score and SCIM-Ⅲ score were significantly different among the 3 groups ( P<0.05), and the MEP-induced state was significantly correlated with the severity of spinal cord injury (ASIA total score) ( r=0.668, P<0.001). Conclusions:In patients with acute cervical hyperextension injury and CCS, the MEP latency is prolonged, the amplitude lowered, and the motor threshold enhanced. The MEP latency is strongly correlated with the severity of spinal cord injury and upper limb motor function. The MEP-induced state is also closely related to the severity of spinal cord injury.
9.Evaluation of the performance of systems for whole blood C-reactive protein detection: a multi-center study
Juan CHENG ; Huaiyuan LI ; Haipeng LIU ; Yuxin WANG ; Jin XU ; Shangyang SHE ; Wei QU ; Yidong WU ; Guixia LI ; Junmei YANG ; Liya MO ; Yun XIANG ; Jiangwei KE ; Liyue KUI ; Lei ZHENG ; Hongbing CHEN ; Zhili YANG ; Xin LYU ; Hong ZHANG ; Zhenhua TANG ; Lijuan MA ; Hongquan LUO ; Xiangyang LI ; Wenli ZHANG ; Hui JIA ; Huiming YE ; Lijun TIAN ; Qiuhui PAN
Chinese Journal of Laboratory Medicine 2021;44(7):633-643
Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.
10.Application value of chest CT angiography in active pulmonary tuberculosis complicated with pulmonary embolism
Liang TANG ; Zhili HOU ; Lingshan ZHONG ; Zhiling LI ; Zhiheng XING ; Jing XU
International Journal of Biomedical Engineering 2021;44(5):374-378
Objective:To investigate the imaging characteristics of chest CT angiography in patients with active pulmonary tuberculosis complicated with pulmonary embolism, so as to improve the detection rate of active pulmonary tuberculosis complicated with pulmonary embolism.Methods:The clinical data of 103 patients with active pulmonary tuberculosis treated in Tianjin Haihe Hospital from January 2013 to January 2020 were retrospectively analyzed, including general conditions, symptoms and complications. According to the occurrence of pulmonary embolism, the patients were divided into active pulmonary tuberculosis complicated with pulmonary embolism group (study group, n=43) and active pulmonary tuberculosis without pulmonary embolism group (control group, n=60). The time between the onset of pulmonary embolism and the onset of tuberculosis of the patients in the study group was collected. The chest CT imaging characteristics of the patients of two groups were analyzed. The imaging characteristics, embolism distribution and secondary changes of the patients in the study group were summarized. Results:Time from onset of tuberculosis to pulmonary embolism of the patients in the study group was about 60 days (14 days to 75 days). The incidence of chest tightness and dyspnea of the patients in the study group was significantly higher than that in the control group (all P<0.05). The number of lung lobes involved in lung lesions of the patients in the study group was significantly higher than that in the control group ( P<0.05). The incidence of lesions in the middle lobe of the right lung, the tongue lobe of the left lung and the lower lobes of both lungs of the patients in the study group was higher than that in the control group (all P<0.05). The incidence of peripheral pulmonary embolism was significantly higher than that of central pulmonary embolism ( P<0.05). However, the incidence of atelectasis, pulmonary artery widening, and right heart enlargement in the patients with central pulmonary embolism was significantly higher than that in the patients with central pulmonary embolism (all P<0.05). Conclusions:Multi-slice spiral CT chest angiography can show some important imaging manifestations of patients with active pulmonary tuberculosis and pulmonary embolism, which is helpful for the early detection of the disease and the improvement of its prognosis. Multi slice spiral CT chest angiography can show some important imaging manifestations of patients with active pulmonary tuberculosis complicated with pulmonary embolism, and timely detection is helpful to improve the prognosis of patients with active pulmonary tuberculosis complicated with pulmonary embolism.

Result Analysis
Print
Save
E-mail